The water filter is gross, can I clean it or do I need to get a replacement?
No 066 mean Failure to read impulses by volumetric flow meter of turbine during coffee dispensing.
The Possible causes are.
1. No Water - check water mains.
2. Broken water pump- Check water pump if it stuck or completely damage replace.
3. The coffee dose is too much- reduce the coffee dose.
4. Coffee ground is too fine- Adjust grinder to more gross coffee.
5. Clogged filters -Replace filters.
6. Coffee solenoid valve clogged or defective -Clean it o replace it.
7. Broken flow meter- Clean from scale deposits or replace.