I have an error code f-9 on Kenmore Elite Ultra wave Microwave Hood Combination Model 721-63683300.

  • Anonymous Mar 12, 2014

    what is error code F5? what is the typical life of a microwave?

×

2 Answers

William Miller

Level 3:

An expert who has achieved level 3 by getting 1000 points

Superstar:

An expert that got 20 achievements.

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

  • Kenmore Master 9,179 Answers
  • Posted on Nov 23, 2008
William Miller
Kenmore Master
Level 3:

An expert who has achieved level 3 by getting 1000 points

Superstar:

An expert that got 20 achievements.

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Joined: Sep 15, 2006
Answers
9179
Questions
3
Helped
4479488
Points
21747

Anonymous

Level 1:

An expert who has achieved level 1.

  • Contributor 1 Answer
  • Posted on Aug 07, 2009
Anonymous
Contributor
Level 1:

An expert who has achieved level 1.

Joined: Aug 07, 2009
Answers
1
Questions
0
Helped
1093
Points
4

I would like to repair the kenmore mocrowave myself, it has the error code f-9. Do I need to let the micrwave sit for a wile so the hi voltage can disipate from the inverter or magetron

Ad

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

Twice my new kenmore microwave has just started beeping with the error code E11 appearing on the screen.Have to unplug it to stop it. WHat is going on?

I think this microwave oven uses an inverter to control the power output of the magnetron. Usually the microwave will advertise this feature with a trade name like "accu-wave" or "true-power" or some similar label on the front of the microwave. Assuming that is the case here, then the E11 error means a bad inverter

If you need further help, reach me via phone at https://www.6ya.com/expert/ronald_e6b9572cebe3ad27

1helpful
1answer

9Fp and microwave cuts off

F-9 means the inverter board has failed. A bad magnatron can also cause this code. Recommend replace the Mag. and inverter board.
0helpful
1answer

UNIT POWERS OFF AND DISPLAYS "F-9"

an inverter failure. This can sometimes by caused by a power surge or glitch through the electrical lines. You can sometimes clear this fault by completely unplugging the microwave for 1 minute. Plug it back in and see if the fault code returns. If it does, then you have an internal component failure that will need to be serviced by a technician. Microwaves must be serviced by technicians due to the inherent dangers involved in repairing these appliances. Internal capacitors can retain a lethal electrical charge even though the unit is completely unplugged. A microwave radiation leakage test must be performed on the unit following any internal component repair
3helpful
1answer

F-9 Error code

The F9 error code indicates a failed inverter. If resetting the unit does not help you will need to have the inverter & harness checked.


http://media.fotki.com/1_p,wbgdfgsrsttwqwbxgtqsskgwtqkq,vi/kgdfkfrkkxkfdtftrfb/1/1303472/5961857/image45625img-or.jpg

This can sometimes by caused by a power surge or glitch through the electrical lines.
You can sometimes clear this fault by completely unplugging the microwave for 1 minute.
Plug it back in and see if the fault code returns.
If it does, then you have an internal component failure that will need to be serviced by a technician.
Microwaves must be serviced by technicians due to the inherent dangers involved in repairing these appliances.
Internal capacitors can retain a lethal electrical charge even though the unit is completely unplugged.
A microwave radiation leakage test must be performed on the unit following any internal component repair.

It does not ALWAYS indicate a inverter control board problem however in other brands/models.
LG's service manual (for an example) suggests the f-9 code could be due to line voltage, magnetron, inverter module, "Relay2", or a loose connection between door/magnetron/control pcb.
Other indications might help narrow down these choices before having to pull out your multimeter and crack open the microwave case.
For example, if the microwave works, but heats slowly, then the troubleshooting manual narrows your choices down to magnetron or line voltage problems, and pretty much rules out the other possibilities.

Thanks for using FixYa - a 4 THUMBS rating is appreciated for answering your FREE question.
0helpful
1answer

F9 Error

You can find exploded views and order parts by entering your model number at the Sears parts site.

We're happy to help you with free advice and we'd appreciate your thoughtful rating of our answer.
22helpful
4answers

Kenmore ultra elite microwave hood combination

F9 code can mean something different depending upon the particular model.....
1.) IF your Microwave uses "UltraWave technology"/"SmartWave technology"...Then either the Magnetron has failed or the Inverter board has failed OR maybe the control board has failed (HUH?).
2.) IF your Microwave does NOT use "UltraWave technology"/"SmartWave technology" then one or more of the door switches has failed.

** "UltraWave technology"/"SmartWave technology" **
I'll explain a few things about this wonderful technology...
The control board (accepts the pushbutton commands) has to talk to the inverter board to tell it how much power should be applied to the magnetron. The inverter board will then power the magnetron and inform the control board if the magnetron is working OK.
If there is something wrong with the magnetron or inverter board or a there is a communication breakdown between the control board and the inverter board...WA-LA-----F9----

A pretty reliable test for the Magnetron is to operate the oven and listen for a ticking sound 5-6 times about a second apart. If you can hear the ticking....The magnetron has failed..if no ticking, the control or inverter board failed.

Note: This 'technology' may come in other flavors as well
Not finding what you are looking for?

1,103 views

Ask a Question

Usually answered in minutes!

Top Kenmore Microwave Ovens Experts

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Cindy Wells

Level 3 Expert

6688 Answers

Paul Carew

Level 3 Expert

3808 Answers

Are you a Kenmore Microwave Oven Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...