Pls help me thank you, sankar chennai
SOURCE: machine trouble call service c0500
Try to power it up with the STOP button pressed.
If not call service team.
SOURCE: error code c0520 konica minolta c350
How to clear a fuser error code (C0500, C0501, C0510, C0511, C0520, C0521).Solution
To clear the fuser error code, perform the following after correcting the cause:
1. With power ON, open the front door and locate the small, rectangular hole below the imaging unit removal tool.
2. Insert a suitable object into the hole to actuate the reset switch .3. The code should clear and a message to close the front door should appear.
1,865 views
Usually answered in minutes!
×