T8845PV
click the link and u should find the instructions
T8845pv has 120Volt input, and 24Volt output.
See wiring diagram for T8845PV controlling 120Volt pump using contactor
http://waterheatertimer.org/How-to-wire-Intermatic-sprinkler-timers.html
If you need further help, I’m available over the phone at https://www.6ya.com/expert/gene_9f0ef4df2f9897e7
Open following link for Intermatic sprinkler timer wiring diagram.
http://waterheatertimer.org/How-to-wire-...
T8845PV is 120Volt timer. Timer output is on 2 yellow wires that carry 24 volts AC.
If you want to control 120Volt pump with this timer, connect the yellow wires to contactor with 24Volt coil.
Open following link for wiring diagrams:
http://waterheatertimer.org/How-to-wire-...
T8845 has 120V AC input, but 24V AC output
However the timer can control 120Volt load if you install additional relay or contactor
Wiring shown on following link:
http://waterheatertimer.org/How-to-wire-...
Gene