Anonymous Posted on May 17, 2017

I have a reliance 606 series water heater. The pilot light won't stay lit after it goes through a heating cycle. I have brushed cleaned the flame arrestor and the LOD screen and I have sandpapered

1 Answer

Marvin

Level 3:

An expert who has achieved level 3 by getting 1000 points

Top Expert:

An expert who has finished #1 on the weekly Top 10 Fixya Experts Leaderboard.

Superstar:

An expert that got 20 achievements.

All-Star:

An expert that got 10 achievements.

  • Reliance Master 85,242 Answers
  • Posted on May 17, 2017
Marvin
Reliance Master
Level 3:

An expert who has achieved level 3 by getting 1000 points

Top Expert:

An expert who has finished #1 on the weekly Top 10 Fixya Experts Leaderboard.

Superstar:

An expert that got 20 achievements.

All-Star:

An expert that got 10 achievements.

Joined: Jun 20, 2008
Answers
85242
Questions
28
Helped
29051804
Points
266281

Possible defective gas valve.

2 Related Answers

Anonymous

  • 1 Answer
  • Posted on Sep 29, 2010

SOURCE: Pilot won't stay lit in Reliance 606 gas water heater

The Reliance 606 has an enclosed thermal couple. Before you try taking that assembly apart take a wire brush to the bottom opening directly under the burner. There is a metal filter on the very bottom of the water heater. It could be that the filter has gotten filled with dust or animal hair. It took a serviceman 2 days to figure this out for me. The water heater has to have good airflow through that filter to work well.

Ad

Anonymous

  • 2468 Answers
  • Posted on Mar 09, 2010

SOURCE: i have a 40 gallon reliance 606 gas water heater,

replace the thermocouple assy in the burner area

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

Hot water tank wont heat water, how do you relight or resat, its a reliance self cleaning 808

Reliance Water Heater Literature ' Owner's Manuals ...

www.reliancewaterheaters.com/resources/instruction-manuals
Welcome to the Reliance Water Heaters Owner's Manual and Installation ... 9 40 EKRT - 40 Gallon Tall Self-Cleaning Electric Water Heater - 9 Year Warranty . ..... 10 50 DHPST - 50 Gallon Electric Heat Pump Water Heater - 10 Year Warranty .

How to light the pilot on a Reliance 606 water heater ...

? 3:27
https://www.youtube.com/watch?v=VU2PsFVd2ug
Jul 12, 2011 - Uploaded by kilroywashere123
How to light the pilot on a Reliance 606 water heater ... How to fixwater heater, will not stay lit - sealed combustion no hot water - Duration: ...

Reliance Water Heaters - Consumer Affairs

www.consumeraffairs.com > Homeowners > Bath & Plumbing

Rating: 1.6 - ‎84 votes
I purchased a Reliance 606 water heater in 2010. ... That they don't TELL you there's areset button or that I'm having conspiracy thoughts ... After several attempts, I was able to relight it. ... It's heading to the junk pile and I will purchase a new reliable (NotReliance) ... Checked breaker and changed breaker still no hot water!
0helpful
2answers

What pilot light assy. do I need to buy for model# 640y0rt4, water heater ??? please wont stay lit

check that the flame sensor is clean. It would be a stiff piece of wire that would sit right over where the pilot lite is. If it is dirty...it wont sense if there is a flame....and if it dosnt sense a flame....it wont let the pilot lite to turn on.
0helpful
1answer

Reliance 606 propane pilot won't stay on when i begin to turn on.its like ite not getting the message or signal,HELP PLEASE

1) Reliance is AO Smith-American, and air intake screen located on bottom of water heater. Clean air intake. Replace thermocouple. First two digits of serial number are year of manufacture.
http://waterheatertimer.org/How-to-troubleshoot-gas-water-heater.html#intellivent
http://waterheatertimer.org/How-to-replace-thermocouple.html

2) Add comment and say what you tried so far.
Include age of water heater.

If you need further help, I’m available over the phone at https://www.6ya.com/expert/gene_9f0ef4df2f9897e7

0helpful
1answer

Reliant 501 Natural Gas won't stay lit

Reliance water heater?
Thermocouple is good if the pilot stays lit continuously.

501 is older model. Unknown if this unit has FVIR protection and sealed combustion chamber or open air intake on front of unit.
http://waterheatertimer.org/pdf/Reliance-2006-Service-Handbook.pdf

With FVIR protection:
Get more fresh air to the unit.
Clean the flame arrestor screen.
Test and replace the thermocouple:
http://waterheatertimer.org/How-to-test-water-heater-thermocouple.html
Inspect and clean burner and combustion parts
Test gas pressure, bleed air out of gas line.
Replace gas control valve.
Test draft air by lighting match and see if smoke is pulled into the vent pipe at draft hood on top of tank.

If you need further help, I’m available over the phone at https://www.6ya.com/expert/gene_9f0ef4df2f9897e7

1helpful
1answer

Reliance 606 Hot water Heating element (Pilot light) won't stay lit

Gas water heaters don't have elements, so I am confused about what type water heater you have..
Look on the side of tank for the label.
Find the brand, and type. Does it show BTUs? Or does it show wattage?
Then re-post question with this information, for best possible answer.
Also post question on Tank forum.
http://www.thetankatwaterheaterrescue.com/forums/forum3/

If you need further help, I’m available over the phone at https://www.6ya.com/expert/gene_9f0ef4df2f9897e7

0helpful
1answer

The pilot won't stay lit on gas hot water tank.

Make sure thermocouple tip is seated inside the burner flame.
Make sure thermocouple is not overtightened. Finger-tight + 1/4 turn.
If the pilot lights, then ECO energy cut off is not tripped, but gas control valve might be bad.
Check color of pilot flame: it should be strong and clear blue.
If pilot flame is weak, or color of flame is yellow-orange: Clean pilot orifice and burner and combustion parts on yearly basis.
Clean air intake screen if applicable.
Increase air supply to water heater. Open a window and see what happens.
Check for adequate draft going up chimney using match under vent hood to see if smoke drafts immediately upwards.
Bleed air out of gas line.
Check gas pressure.

Open following links for troubleshoot resources:
http://waterheatertimer.org/pdf/Pilot-light-will-not-stay-lit.pdf
http://waterheatertimer.org/pdf/Pilot-outage-troubleshooting.pdf
http://waterheatertimer.org/pdf/Vent-spillage-test-atmospheric-gas-water-heater.pdf
http://waterheatertimer.org/How-to-install-gas-water-heater.html#troubleshoot
0helpful
1answer

Reliance 606 natural gas water heater - model #640YORT - water does not stay hot. pilot has to be clicked to heat and then u can use hot water til tank empty and it will not continue to heat water.

If I understand correctly, the pilot light is not staying lit.
You light the pilot and water in the tank reaches temperature.
Once hot water is gone, then pilot light has to be lit again.

Gas pressure is good, and gas is flowing.
Thermostat is working at high end because it cuts off heating.
Vent is working because tank heats up.
Air intake is working.

Gas control thermostat might not be reading low temperature. Replace gas control valve.
Pilot tube might be dirty. Clean burner parts and combustion chamber, and air intake, and vent.
Backdraft might be blowing out pilot. Check for constant updraft by running water heater 5 minutes, and then light match under vent hood and see if smoke goes up.
Very hot air can put out pilot, especially when water heater located in attic. Add ventilation.
Improper vent might have water dripping back down into combustion chamber and putting out pilot light and rusting out the parts. Inspect for rusted parts and water.
http://waterheatertimer.org/How-to-install-gas-water-heater.html#troubleshoot
http://waterheatertimer.org/pdf/Pilot-light-will-not-stay-lit.pdf
16helpful
3answers

Pilot won't stay lit in Reliance 606 gas water heater

The Reliance 606 has an enclosed thermal couple. Before you try taking that assembly apart take a wire brush to the bottom opening directly under the burner. There is a metal filter on the very bottom of the water heater. It could be that the filter has gotten filled with dust or animal hair. It took a serviceman 2 days to figure this out for me. The water heater has to have good airflow through that filter to work well.
Not finding what you are looking for?

2,676 views

Ask a Question

Usually answered in minutes!

Top Reliance Water Heaters Experts

Brad Brown

Level 3 Expert

19187 Answers

john h

Level 3 Expert

29494 Answers

Paul Carew

Level 3 Expert

3808 Answers

Are you a Reliance Water Heater Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...