Hello,
as you didn't specifed the model, here is general description:
The temperature of the fixing film is as follows:
1. has exceeded 100°C, but does not reach 115°C within 1 sec thereafter.
2. has exceeded 140°C, but does not reach 150°C within 1 sec thereafter.
3. has exceeded 160°C, but does not reach 165°C within 1 sec thereafter.
It can be due to faulty fixing heater in models with fixing film, or faulty thermistor's in models with teflon roller.
In most copier's the procedure for clearing is the same.
If it is temporary trouble, you can reset the error:
While copier is showing the error:
1) Press the User Mode key ' * ' .
2) Press '2' and '8' on the keypad at the same time.
3) Press the User Mode key ' * ' on the control panel.
Then choose ( if touch panel ) COPIER, FUNCTION, CLEAR, ERR turn it off and on.
If the model isn't with touch screen instead of pressing on display use the arrows to get to clear press OK and then err and ok, turn off and on.
If the clear doesn't help's call service!
104 views
Usually answered in minutes!
×