What I realised is that the coil temp sensor is located at the buttom of the evap coil. At that position it does sense the change it temp. I had checked another carrier (not the same model) and the coil sensor was located higher up. So I removed it and tied it up higher up on the coil. This is after I had swapped cicuit board, and all sensors. The higher up position allows it to sense a change in temp on the coil.
×