Flotec Corrosion... | Answered on May 05, 2018


If in the past your system can build-up pressure up to 40 psi even if the supply valve is open and water is being used in your house, then your pump impeller maybe already worn out that's why its pumping capacity was reduced.

Flotec Corrosion... | Answered on Mar 20, 2017


Check auto stores for a manual that shows the resistor. You can always Google it, too.

Flotec Corrosion... | Answered on Aug 28, 2015


The tank is an air tank, it works like a cushon and accumulator.

Have you reconnceted the pump? If not fill the pipe that goes to the well with water. It should not drain down, there should be a foot valve that prevents the water from running back into the well. So if the foot valve is working it should not take a lot of water to do this.

Pour water into the suction side of the pump until the pump is as full as you can get it, reconnect the pump and start it up. Yes it does need to be primed

Good luck

Flotec Corrosion... | Answered on May 11, 2015


Put a vacuum gauge into the front drain plug port with the pump installed and see how much vacuum it draws. If it is low get the pump or lines repaired, if not have a well driller check the well point.

Flotec Corrosion... | Answered on Apr 14, 2015


fp 4022-10 3/4 flotec
www.flotecpump.com

Copy;
http://www.flotecpump.com/pdf/FP745.pdf

for parts, pictures, troubleshooting tips etc.

Flotec Corrosion... | Answered on Dec 18, 2014


These holding tanks are pre charged with air which in turn pressurizes the water. The tank has a bladder and an air valve on top. The pre charge ,over time, loses pressure, and the tank has to be pressurized again.
  • The well pump needs to be turned off.
  • The water has to be drained from the tank
  • Air is put into the tank from the air valve on top of the tank, and is measured with a tire air gauge.
  • The pre charge pressure is set to two psi below the pump cut in pressure.
  • In other words if your pump kicks on at 30 psi, the pre charge pressure is set at 28 psi. If the pump kicks in at 20 psi, the pre charge is set at 18psi, etc.
  • After you pressurize the tank, turn water back on.
  • If water comes out of air valve on top of tank, then the bladder is ruptured and you need a new tank.
  • Hope this helps!

Flotec Corrosion... | Answered on Sep 26, 2014


Remove end casing of Flotec motor housing they have a 115v/220v switch, turn to 220v, see website flowtec water. Flotec parts 1-800-365-6832

Flotec Corrosion... | Answered on Sep 16, 2014


The wiring information is in the manual. Are you calling the pressure switch a safety switch?

Flotec Corrosion... | Answered on Jun 18, 2014


Check for power to the pump then check again after the built in pressure switch. You can get the manual from Flotec at: http://www.flotecpump.com/ResidentialResourcePage_resourcepage_ownersmanuals.aspx

If the motor buzzes then there is probably a bad start capacitor.

Flotec Corrosion... | Answered on Jun 18, 2014


Jet pumps are inherently noisy, has it always been this loud? Loud is a subjective measurement and varies from person to person.

Flotec Corrosion... | Answered on Jun 13, 2014


how deep is the well can you hear the pump working.or are you able to pull the pump up to inspect it.or can you place ahose down the well to be sure that water is down there,some pumps have a pressure sensor so when theres no water it switches of so as it does not opperate dry,because this will damage the seals in the pump,hoe this helps.

Flotec Corrosion... | Answered on Jun 05, 2014


Hi,
Those pumps will reach 50# when brand new, but soon the parts wear and then they will not make that pressure anymore...
Instead of replaceing the pump, just back the pressure down a tick or two to get it to shut off and not waste your electric....

Well Pressure Switch Adjustment Water Well Problems


heatman101

Flotec Corrosion... | Answered on Apr 06, 2014


Try cleaning the jet.


26a474b.jpg

Flotec Corrosion... | Answered on Mar 29, 2014

Not finding what you are looking for?
Flotec Corrosion Resistant Shallow Well Jet Pump 1/2HP, 8GPM Logo

177 questions posted

Ask a Question

Usually answered in minutes!

Top Flotec Plumbing Experts

Rolly North

Level 1 Expert

26 Answers

Renee Knafel-Bullock
Renee Knafel-Bullock

Level 2 Expert

353 Answers

Brad Brown

Level 3 Expert

18165 Answers

Are you a Flotec Plumbing Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

View Most Popular

Flotec Plumbing

  • Flotec Plumbing

Most Popular Question

ask question yesterday about flotec 1 hp

  • Plumbing
Loading...