20 Most Recent
Pentair MINIMAX NT TSI IGNITER - Page 4 Questions & Answers
Pentair VS Pump - Error Code 0021
Try this. Hold down the 1 button and the plus and minus button at the same time for about 5 seconds. You should see all the lights light up and the screen will go into reboot and display the model and whatnot. After that see if it comes on by pressing start
Pentair Max-e-therm troubleshooting!?
If you're getting a service system light with the pump on full and good water pressure out of the jets, then you might have a problem with the pressure switch in the heater.
Hi, i am getting key error on my pentair intelliflo
Hi @Vahe, I had same question. I thought its looking for a physical key or something. But what the UI is saying is, you have pressed an invalid key, this key does not have any meaningful action in the current operation/setting you are performing. Nothing wrong with your pump, check the product manual or youtube videos regarding what you are trying to configure.
Pentair Master Temp 125 gas valve "sticking"
Spray the plunger with Garage Door Lubricant.
The warranty is a year, so try claiming on it. Add a few months to the installation date. You bought all the hardware including the heater, and then started digging the ground.
The Applicable Warranty Period is one (1) year from the Purchase Date or 90 Days on the Heating Element
. The warranty does not cover damage caused by improper water chemistry. The warranty will be void if the heater is not installed by a licensed technician, or the heater has been installed on a soft sided pool.
Pentair MasterTemp 125,000 BTU Low NOx Natural Gas ...
My pressure gauge is broken,
Pressure gauges last a long time. When a gauge fills with water, it is usually from an outside source, like rain or getting wet. A gauge can be purchased at your local hardware, just get the same pressure reading and the identical size threaded connection. Make sure there is no pressure in the system, unscrew the old gauge, put dope or tape on the threads of the new one and screw it in.
Gary
Code pentair code 128r14
Your main bord model number and Revision. model 128 Revision 14. This will appear every time the system reboots.
Pacfab mimimax 100 doesn't stay on
if still has power check gas pressure if ok check burner tubes for blockage if unit tripps breaker check ignitor if lights but goes out check flame sensor
What is pentair code ad0
ado is a code for stack flue temp set up if you look at a pentair chart you can find the procedure to change that
Not finding what you are looking for?