Spa drains when turned on
The problem is in your plumbing. Someone put a valve in an incorrect position. I would have to see a picture of your plumbing but if you can follow the flow of water. When you put it in spa mode, look at which valves turn and which ports open up. If it is doing anything other then sucking water from the spa and returning it only to the spa, then that is why it is draining. Again it would be great if you had a picture. What I have seen before is somebody plumbing in the pipe for a pool cleaner after the valve that send water to the spa. This would result in water from the spa slowly draining out of the pool sweep line. Good luck.
Viron connect 10
how do i remove a fault 1 indication on the solar heating screen
How do I replace the temperature sensor
if it is on the aqualink it is the one hoseclamped to the pipe coming from the pump if the temp sensor on the heater it is mounted to the header of the heat exchange
How do you fix a fl 7 firemen's switch open message
connect the firemans switch to the heater pins 1 and 2 on the long green plug then enable the heater on the one touch make sure heater is set to highest setting make sure wires go to pool and com then it will work your aqualink will control heat settings