Hayward gas heater is Flashing 111 and says service. Have no idea what to do.

I just had this happen. I was struck by lightning so yours might be different. I replaced the display board and the control board and my heater is up and running.
6/20/2022 3:00:32 AM • Hayward Pool &... • Answered on Jun 20, 2022
0helpful
3answers

Our Hayward gas heater keeps giving us a H5 error

Could the Error code be HS? That is high temperature limit. Perhaps you' don't have enough flow, allowing the heater to heat the water to a temperature higher, than the thermostat setting. Make sure your bypass valve is closed, allowing full flow through the heater. Check your filter pressure differential , and skimmer baskets.
You didn't give your model number, and there are many models. You can go the Hayward website below and select your exact model number and download the manual. The manual will explain each error code.
http://www.haywardnet.com/inground/products/manuals.cfm
5/28/2022 2:19:55 PM • Hayward Pool &... • Answered on May 28, 2022
0helpful
1answer

I have a Hayward H 150 and am getting a HS error code.

possible internal bypass spring bad not letting enough water through
5/19/2022 3:29:56 AM • Hayward Pool &... • Answered on May 19, 2022
0helpful
1answer

Valve #sm2-pp3 will this fit Hayward S244S Sand filter?

the valve is for pentair check the unions see if they fit
2/10/2022 4:05:34 AM • Hayward Pool &... • Answered on Feb 10, 2022
0helpful
1answer

My Hayward 11KW Spa Heater is not heating. I replaced both elements and I am getting power to both elements.

make sure the recirculation pump that goes to heater piping is working
1/1/2022 5:36:14 AM • Hayward Pool &... • Answered on Jan 01, 2022
0helpful
1answer

On my Hayward pool and Spa heater model no. CSPAXI11 the contactor coil has power going in, but not out, is it bad?

Question edited for clarity. Question moved from Cars and Trucks category. Yes the contactors take all the strain. The internal contacts are probably damaged, just replace it as they do wear out.
11/11/2021 3:54:42 AM • Hayward Pool &... • Answered on Nov 11, 2021
0helpful
1answer

Hayward led pool light stays on for 10 seconds then stops

check voltage at transformer possible bad
9/30/2021 3:18:51 AM • Hayward Pool &... • Answered on Sep 30, 2021
0helpful
2answers

And does a Hayward dreamline model s190tscp use

S190tscp takes 175lbs of sand
7/12/2021 3:19:19 PM • Hayward Pool &... • Answered on Jul 12, 2021
0helpful
2answers

Can't get impeller off Hayward PowerFlo matrix, tried holding with screwdriver but can't break free

Soak the shaft and impeller splices with diesel fuel or store bought nut/bolt loosening spray and tap often over 24 hour period while it soaks and permeates the contact area. Tap impeller with a wooden mallet to remove,
6/22/2021 6:22:07 AM • Hayward Pool &... • Answered on Jun 22, 2021
0helpful
1answer

Hayward HPX26024139 schematic

http://www.haywardnet.com/pdfs/Heatpump-Troubleshooting-Guide.pdf
5/28/2021 10:54:41 PM • Hayward Pool &... • Answered on May 28, 2021
0helpful
1answer

H200fdn pool water heater. Why doesn't blower start?

its trying to start check voltage to fan if ok bad fan motor if no check safety circuit
12/19/2020 6:22:08 AM • Hayward Pool &... • Answered on Dec 19, 2020
0helpful
1answer

How do you get to centrifugal switch on Hayward PowerFlo matrix

Are you sure it has a centrifugal switch? Capacitor start/ capacitor run have been the standard for a good number of years.
10/26/2019 3:21:48 AM • Hayward Pool &... • Answered on Oct 26, 2019
0helpful
1answer

Manual for Hayward pool products DE 4800

Hayward's website has manuals for all their products.
10/26/2019 3:15:44 AM • Hayward Pool &... • Answered on Oct 26, 2019
0helpful
1answer

I have Sumheat S3 Hayward pool heater I also do not have 24 V output between the blue and yellow cables coming from the transformer. Do I need to replace the transformer? Thanks Cecilia

The 24v is called the secondary and sometimes called the out-put. Make sure you have 240v on the primary, sometimes referred to as the in-put. If you have primary voltage then you should have secondary voltage, if not then replace transformer. Make sure the secondary, 24v control fuse is the correct size and present. If the secondary is shorting together or to ground somewhere, it will cause damage to the transformer.
8/18/2019 11:26:46 AM • Hayward Pool &... • Answered on Aug 18, 2019
0helpful
2answers

I have a Hayward H400 pool heater. I don’t heat my pool so I never use it but I do turn it on once or twice a year for about five minutes to make sure it’s working, which right now it fires up just fine. The problem I am having is once the pump turns off, the blower on the heater turns on & stays on. I can’t get it to turn off unless I cut the power. This is obviously a problem because I can’t have the pump on a timer because as soon as the pump turns off, the blower on the heater will run for 16 hours until the pump kicks back on. I’ve done a lot of research & can’t find a solution or anyone who has experienced this problem. Any advice would be appreciated.

Call a qualified electrician. More information would be needed to accurately trouble shoot your issue. Do you have automation connected to your heater? Is the heater trying to fire when the pump is off or is it ONLY the fan? Try disconnecting your Water Pressure switch on the heater and see if the issue stops. With WP switch disconnected the heater should not work and the fan should stay off. Replace WP switch and see what happens. Call a QUALIFIED electrician.
8/12/2019 3:19:38 PM • Hayward Pool &... • Answered on Aug 12, 2019
0helpful
1answer

I have a Hayward pump it says it has a switch on the pump but I cannot find it where is it located

Underneath the back cap on motor
7/30/2019 2:44:37 PM • Hayward Pool &... • Answered on Jul 30, 2019
Not finding what you are looking for?
Hayward 250kbtu Ng Pool Heater - Inground Logo

127 questions posted

Ask a Question

Usually answered in minutes!

Top Hayward Pool & Spa Experts

Jay Finke
Jay Finke

Level 3 Expert

1397 Answers

john h

Level 3 Expert

29494 Answers

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Are you a Hayward Pool and Spa Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

View Most Popular

Hayward Pool & Spa

  • Hayward Pool & Spa

Most Popular Question

location drain plug hayward h series

  • Pool & Spa
Loading...