Dream Maker Spas Dream Maker Ez Spa Hot Tub - Answered Questions & Fixed issues
Will a flow switch stop the tub of any operation
Is the board getting power, is the control lighting up?Do you see any error codes on the top side control? Improper flow will give you an error code, caused by flow issues or a faulty flow switch. Make sure all gate valves are open and the water can flow freely.If not then check your Hi Limit sensor. This is the overheat safety sensor if it fails the tub will not function at all.
The spa won't shut off. It keeps overheating
Check the filtration cycle. I have seen several hot tubs over the years where the owners have accidentally changed the filter cylce duration without realising.
If the filter cycle duration is set too long it may/will overheat.
It's also possible that you may also have a problem with the PCB. This would need to be checked by a spa technician who knows the system well.
Regards,
Ian.
http://hottub.synthasite.com
We have a dreammaker spa, how do we drain it? the
The Fantasy has a drain located in the toekick of the spa. You have to first remove the drain cap, attach a hose if you wish, spin the outer black ring counter clockwise to start the water flow, then pull the outer ring out away from the tub to increase the drain to full flow.
I understand that a screw driver is often needed to pull the outer ring out to achieve full flow. Therefore, I suggest another method. Take a garden hose and place it in front of the jet while the spa jets are on. This will force water flow thru the hose and prime the hose. Once you see water running from the other end of the hose, drop the hose in front of the spa jet into the footwell and as long as the loose end is lower than the end in the footwell, a siphon will drain the spa as fast as the spa drain will. Remember to turn off electric to the spa once you have established a siphon. You may have to bucket the last bit of water in the footwell. Goodluck.
My spa is at 89 and its set for 104 and the pump will not cut on what is the problem
You may be in economy mode. Economy only heats the water during a programmed filter cycle. You want it to be in standard mode which turns on the hot tub once the water is 2 degrees below the desired temperature. There should be a mode or program button on your topside. One some systems you'll have to hit prog/mode button then the temp up button to change the mode. There is also a sleep mode. Never used it not sure what it's for.
What does code ic mean?
I have not seen an ic error code. I have seen ICE several times. So either you do not have the original pack that came with the spa or your display may be malfunctioning.
What is your hot tub doing while the ic code is pressent?
Portable Hot Tubs and Spas On Sale
Dream maker ez spa has power but jets won't turn on. Fuse is fine and unit is getting power
Thanks for the question! It could be several different issues. First, It's possible the topside jet button is malfunctioning and may need to be replaced. Is there any type of error message flashing on the topside display? Second, The pump may be bad, If it's a 2 speed pump it's possible to still circulate the water and maintain temp while the pump is malfunctioning. Depending on your level of "do it yourselfness" you may attempt to troubleshoot and repair it on your own. Checking for an error code on your topside is the best 1st step to take. I wish I could be of more assistance however, without being able to inspect it myself those are the best suggestions I can muster. Good luck & I hope I was able to provide at least some assistance. =)
6 month old jacuzzi hot tub has started leaking intermittently , any help here to solve this problem
if its all wet, dry it out with a fan and then start your search, if it's under a pump, it is a shaft seal, a fairly cheap fix, i charge 20 to do it and I do some preventive measures to the pump so it can be serviced in the future without damage (smart).
but it also might be a loose jet nut, they can be tricky to get at, but if carefully done can be tightened with a dull screwdriver and a hammer tapping on the edge of the nut.
Hope this gets ya running again. ask if you need more help, and don't forget to vote if i was of help
Not finding what you are looking for?