20 Most Recent Ebac CS60 Dehumidifier Dehumidifier - Page 7 Questions & Answers

0helpful
1answer

What kind of hose do you need to utilize the hose hookup? I'm tired of emptying the bucket.

SOME OF THEM JUST USE A STANDARD GARDEN HOSE . SINCE WE CAN NOT SEE WHAT YOU HAVE
7/16/2021 12:44:37 AM • Dehumidifiers • Answered on Jul 16, 2021
0helpful
2answers

I have a danby ddr7009ree

The continuous drain hole (where the hose is inserted) is clogged. To remove the clog, you will need an 18" long plastic Zip Tie (or something similar. But NO wire cost hangers) that will fit into the hole.
Insert it slowly and push until you reach a bend in the tubing. You will need to gingerly work it past this bend until the Zip Tie bottoms out or you run out of Zip Tie. Then, while rotating it, pull it out slowly. As you reach the end of the Zip Tie, be prepared for some water to follow. Also make sure that the drain hose, when reinserted is not crimped and the end is lower than the drain hose connection. The unit does not have a pump. It relies on gravity to drain water through the hose.

Hope this helped you to solve the problem. Please let me know. Thanks.
7/10/2021 4:19:43 AM • Dehumidifiers • Answered on Jul 10, 2021
0helpful
1answer

I have an error message E9 on my dehumidifier. Its the 043-5796-6 model 70 pints

That is a moisture sensor error and probably needs replacing.
7/2/2021 3:31:58 PM • Dehumidifiers • Answered on Jul 02, 2021
0helpful
1answer

My Keystone keeps shutting down with an EC code. My filter is clean, there's suffient space around the unit and the temperature is set to 60. What is the problem?

EC usually means that the compressor overheated while trying to move the refrigerant through the compression part of cycle. This usually happens when the refrigerant is low due to a leak in the system. Sometimes, you can spot the problem when ice builds up around the coils near the leak. This is not a user-repairable problem. If your dehumidifier is under warranty, contact the manufacturer. The entire system has to be checked to identify the leak. Then after the leak is fixed, the correct amount of refrigerant appropriate to the model has to be added. (In most places, freon and freon replacements must be handled by a trained professional.) I hope this helps. Cindy Wells
7/1/2021 4:43:09 PM • Dehumidifiers • Answered on Jul 01, 2021
0helpful
1answer

Where can I get a manual for Kul dehumidifier ku34513?

http://www.manualsonline.com › ma...
Kul Dehumidifier ku34513 manual for ku34513 ...
6/22/2021 2:45:22 PM • Dehumidifiers • Answered on Jun 22, 2021
0helpful
1answer

Need Electrical Diagram for Hisense Dehumidifier

Contact Hisense directly to request the diagram. Be sure to identify model.
6/19/2021 9:41:08 PM • Dehumidifiers • Answered on Jun 19, 2021
0helpful
1answer

I have a Garrison 28 pint, 043-5436-2 dehumidifier. It gives off a lot of heat when turned on. What can I do?

They do, because it is a refrigeration unit. Just make sure, fans and air filter screens are clean.
6/15/2021 3:42:03 AM • Dehumidifiers • Answered on Jun 15, 2021
0helpful
1answer

Meaco DD8L Zambezi dehumidifier. What does error C1 mean?

https://www.appliancesdirect.co.uk/files/pdf/meaco-dd8l-zambezi-manual.pdf
4/24/2021 12:46:50 PM • Dehumidifiers • Answered on Apr 24, 2021
0helpful
1answer

Where can I buy replacement filter for Novum Omikron 3000 dehumidifier

google it up
3/24/2021 11:20:14 AM • Dehumidifiers • Answered on Mar 24, 2021
0helpful
2answers

Should the fan shut off when the humidity setting has been reached for model Frigidaire CAD504DWL 50-Pint Two Speed?

Thank you for your post, friend!

I see that your question is if the fan should shut off once it has reached the recommended setting. The fan will run even when the compressor cuts off so that air can pass over the sensor coils to check the humidity. This is a normal operation. I hope this is helpful. -Matt

2/22/2021 4:00:35 PM • Dehumidifiers • Answered on Feb 22, 2021
0helpful
1answer

I need a manual for a air force dehumidifier bqdc20

Contact Air Force directly to request the manual.
1/15/2021 2:03:00 PM • Dehumidifiers • Answered on Jan 15, 2021
0helpful
1answer

I have a Neostar dehumidifier that is not working the alam keeps comeing on after about 30 seconds can you help me with this

how do i stop the alarm coming on after 30seconds ive cleaned the filter but light still comes on
12/7/2020 6:22:49 PM • Dehumidifiers • Answered on Dec 07, 2020
Not finding what you are looking for?
Dehumidifiers Logo

2 questions posted

Ask a Question

Usually answered in minutes!

Top Ebac Dehumidifiers Experts

NOEL
NOEL

Level 3 Expert

8606 Answers

Are you an Ebac Dehumidifier Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

View Most Popular

Ebac Dehumidifiers

  • Ebac Dehumidifiers

Most Popular Question

ebac xl dehumidifier not collecting

  • Dehumidifiers
Loading...