20 Most Recent Whirlpool 25.4 Cu. Ft. Side-by-Side Refrigerator w/Thru-the-Door Ice & Water - Satina Stainless-Look - Page 4 Questions & Answers

0helpful
1answer

Freezer icing up

If your freezer is icing up, one of the components in the defrost circuit failed. This circuit is made up of the defrost heater, defrost thermostat (both located in the freezer section close to the evaporator coils) and a defrost timer (newer unit incorporated this onto the control board). The defrost heater and thermostat can be checked with an ohm meter (10-100 ohms common - infinity bad component) but the defrost timer can't be checked without specialized test gear.NOTE: If you completely defrost your freezer, it should give you about two weeks of normal operation before the problem comes back which gives you time to troubleshoot the components and order the parts.
1/8/2012 3:10:02 PM • Whirlpool 25.4... • Answered on Jan 08, 2012
0helpful
1answer

Won't make ice

It probably still MAKES ice, it just doesn't dispense it. The ice drawer may be blocked. Remove the ice drawer, empty it, rinse it through with luke warm water - including all non electrical moving parts, dry thoroughly, replace, give the machine time to replenish the ice, should solve your problem. Assuming it is just that it is only that it is blocked.
12/27/2011 1:18:15 PM • Whirlpool 25.4... • Answered on Dec 27, 2011
0helpful
1answer

Model No 8.58616E+1 Fridge not keeping

First I would check cold control. Thats where you turn it off, if your temp is not warm. it seems
to be defective and not shutting off. If your temp is warm proceed with the following.
I would check the fan in the freezer. Listen to see if it is running
It moves air to the ref from the freezer
Then check to see if freezer control is turned WARMER, which makes the Ref. colder
Also this might be a common Defrost problem, Ice
is not being melted by the defrost system.The fan can't blow through the coils into the fridge.
Take out back panel of freezer to check for ice buildup. The coils should be clean.
There are three components to a defrost system- a heater,heater thermostat, and a timer unless you have a defrost electronic card.
Its best handled by a Technician but you could possibly do it by taking your model number to the nearest appliance parts store and asking for the parts. They are mostly located in freezer ,behind back panel on freezer coils.except the card which is usually located in ref The parts store will have info
Also check fan undernearh Ref in the rear
Clean condenser coils underneath
Check cold control (thats where you turn it colder)
.I'm including my article on Refrigerator Repair for your help and convenience.;
Please click or copy and paste into browser for Article
http://www.fixya.com/support/r5816737-fix_refrigerator_psychologically
Thanks for using fixya
Leo Ponder
imufo2
Please VOTE FOR ME If this was helpful
12/7/2011 7:43:11 AM • Whirlpool 25.4... • Answered on Dec 07, 2011
0answers

ED5THAXMS10

Be the first to answer 12/6/2011 6:07:01 PM • Whirlpool 25.4... • Posted on Dec 06, 2011Be the first to answer
0helpful
1answer

Frigg side wont stay cool ,If im luck it will get down to 42 degrees

is it a frost free ?
12/6/2011 12:46:43 AM • Whirlpool 25.4... • Answered on Dec 06, 2011
0helpful
1answer

Ice maker won't make ice

This problem is very common.The ice maker water passing line gets clogged or blocked by ice cube or gets frosted by ice or the water valve,which lets water to ice maker,tray, that valve gets faulty.

The ice maker not working.-------------

Its the problem of water inlet valve. It's a dual valve. This valve has two tubes in it. One for water dispenser and one for ice maker chamber. The one side of valve is working, but other side of the valve is not working. The valve is got stuck in one position

Click this link below to troubleshoot the problem: ----

http://technoanswers.blogspot.com/2011/06/ice-maker-stopped-working.html


---------------


This will help. Thanks. Helpmech.

10/10/2011 7:52:06 PM • Whirlpool 25.4... • Answered on Oct 10, 2011
0helpful
1answer

My fridge is freezeing my food is there some thing

Please VOTE FOR ME AND GIVE ME YOUR TESTIMONIAL IF POSSIBLE, IF THIS WAS HELPFUL
ITWILL BE MUCH APPRECIATED.
The cold control needs replacing. Thats the knob with the numbers that turn the Ref OFF and ON.
What I do is call my local Appliance Parts Store with my model no. They are extremely helpful .
Get freezer and ref thermometer. Ref is probably too cold.
Freezer should be 0 to 10 degrees. Ref 33 to 35
If you need more help, Go here:

http://www.applianceaid.com/procedures.html

I'm including my article on Refrigerator Repair for your help and convenience.;
Please click or copy and paste into browser for Article

http://www.fixya.com/support/r5816737-fix_refrigerator_psychologically

MORE TIPS AND TRICKS:
-----------------------------------------------------------------------------------------------------
STOP PAYING FOR EXPENSIVE WATER FILTERS FOR YOUR REF. DO THIS====
http://www.fixya.com/support/r9962087-stop_paying_high_price_refrigerator
-------------------------------------------------------------------------------------------------------
WATER SPLASHING IN FREEZER AT ICEMAKER
THE FILL TUBE IN BACK OF REFRIGERATOR CAN SLIP
AGAINST THE FILL RESERVOIR CAUSING A PARTIAL BLOCKAGE
OR BECOME CLOGGED WITH ICE.
REMOVE THE ICEMAKER AND INSPECT THE FILL TUBE.
RUN WATER IN TUBE TO ELININATE BLOCKAGE AND CHECK
TEMP IN FREEZER. IF TEMP IS BELOW 0 DEGREES, THATS
OVERKILL AND USUALLY A WASTE OF ELECTRICITY TO KEEP IT THAT COLD, NOT TO MENTION THE FILL TUBE FREEZING UP
----------------------------------------------------------------------------------------------------------------------
Thanks for using fixya
Leo Ponder
imufo2
Please VOTE FOR ME AND GIVE ME YOUR TESTIMONIAL IF POSSIBLE, IF THIS WAS HELPFUL
ITWILL BE MUCH APPRECIATED.
9/27/2011 9:14:50 PM • Whirlpool 25.4... • Answered on Sep 27, 2011
0helpful
1answer

Temperature stuck on 4 and a red square flashing

NOTE: This
is a multi-solution answer since I don't have all the tech from your question to pinpoint your problem
But the solution is in here generically, if you read and study the solutions very,very carefully.
First I would check cold control. Thats where you turn it off, if your temp is not warm. it can
be defective and not shutting off. If your temp is warm proceed with the following.
I would check the fan in the freezer. Listen to see if it is running
It moves air to the ref from the freezer
Then check to see if FREEZER CONTROL is turned WARMER WHICH MAKES THE REF COLDER AND VICE-VERSA. SEE?
The ref. temp should be about 33-35
The Freezer temp should be 0 to 10 Any thing below these temps is overkill and a waste of elect
The higher the number you turn it up to is the coldest
But is probably a common defrost problem The ice build up
is not being melted by the defrost system.The fan can't blow through the coils into the fridge.
Take out back panel of freezer to check for ice buildup. The coils should be clean.
There are three components to a defrost system- a heater,heater thermostat, and a timer unless you have a defrost electronic card.
Its best handled by a Technician but you could possibly do it by taking your model number to the nearest appliance parts store and asking for the parts. They are mostly located in freezer ,behind back panel on freezer coils.except the card which is usually located in ref The parts store will have info
Also check fan undernearh Ref in the rear
Clean condenser coils underneath
Make sure back cover is on the fridge. Some take them off and throw them away.
make one out of cardboard if its gone, using the holes of the old one.
.I'm including my article on Refrigerator Repair for your help and convenience.;
Please click or copy and paste into browser for Article

http://www.fixya.com/support/r5816737-fix_refrigerator_psychologically

If you need more help go here:

http://www.applianceaid.com/procedures.html

MORE
TIPS AND TRICKS:
-----------------------------------------------------------------------------------------------------
STOP PAYING FOR EXPENSIVE WATER FILTERS FOR YOUR REF. DO THIS====
http://www.fixya.com/support/r9962087-stop_paying_high_price_refrigerator
-------------------------------------------------------------------------------------------------------
WATER SPLASHING IN FREEZER AT ICEMAKER
THE FILL TUBE IN BACK OF REFRIGERATOR CAN SLIP
AGAINST THE FILL RESERVOIR CAUSING A PARTIAL BLOCKAGE
OR BECOME CLOGGED WITH ICE.
REMOVE THE ICEMAKER AND INSPECT THE FILL TUBE.
RUN WATER IN TUBE TO ELININATE BLOCKAGE AND CHECK
TEMP IN FREEZER. IF TEMP IS BELOW 0 DEGREES, THATS
OVERKILL AND USUALLY A WASTE OF ELECTRICITY TO KEEP IT THAT COLD, NOT TO MENTION THE FILL TUBE FREEZING UP
----------------------------------------------------------------------------------------------------------------------
Thanks for using fixya
Leo Ponder
imufo2
Please VOTE FOR ME AND GIVE ME YOUR TESTIMONIAL IF POSSIBLE, IF THIS WAS HELPFUL
ITWILL BE MUCH APPRECIATED.
9/27/2011 8:13:59 PM • Whirlpool 25.4... • Answered on Sep 27, 2011
0helpful
1answer

My defrost tray is full of water. why? and how do

The drain in the freezer behind back lower panel
needs opening. You can see it at the bottom of the back panel
underneath the evaporator coils. (The cold coils)
Run Hot water in the drain until it clears or use a hairdryer.
When the defrost melts the water it goes down the drain
If the drain is clogged with Ice or ? The defrost water
overflows into the ref. or freezer or on floor
Run Hot water in the drain until it clears or use a hairdryer.
Also check fan undernearh Ref in the rear
Clean condenser coils underneath
.I'm including my article on Refrigerator Repair for your help and convenience.;
Please click or copy and paste into browser for Article
http://www.fixya.com/support/r5816737-fix_refrigerator_psychologically
If you need more help GO HERE:

http://www.applianceaid.com/procedures.html

Thanks for using fixya
Leo Ponder
imufo2
Please VOTE FOR ME IF THIS WAS HELPFUL
9/27/2011 8:02:20 PM • Whirlpool 25.4... • Answered on Sep 27, 2011
0helpful
1answer

Loud click when from back (where compressor is) it

:
Hi!
A relay starts the compressor with a higher voltage and then quickly kicks out
It does a lot of clicking (trying to start over and over again)
If thats what is happening with yours
Its best for a tech to replace The relay but you can do it
Take your model number to your Local Appliance parts store they will have a diagram
showing you how to install the relay. Its called a hard start relay
I use part no ERP410 POWER START RELAY, CAPACITOR AND OVERLOAD all in one. (110 v)

If you still have trouble Go Here:

http://www.applianceaid.com/procedures.html

Thank you for using fixya
Leo Ponder
PLEASE VOTE FOR ME IF THIS WAS HELPFUL
9/26/2011 12:47:02 AM • Whirlpool 25.4... • Answered on Sep 26, 2011
0helpful
1answer

Whirlpool model # ED5LHAX65261 ice maker has

NOTE: This
is a multi-solution answer since I don't have all the tech from your question to pinpoint your problem
But the solution is in here generically, if you read and study the solutions very,very carefully.
First I would check cold control. Thats where you turn it off, if your temp is not warm. it can
be defective and not shutting off. If your temp is warm proceed with the following.
I would check the fan in the freezer. Listen to see if it is running
It moves air to the ref from the freezer
Then check to see if FREEZER CONTROL is turned WARMER WHICH MAKES THE REF COLDER AND VICE-VERSA. SEE?
The ref. temp should be about 33-35
The Freezer temp should be 0 to 10 Any thing below these temps is overkill and a waste of elect
The higher the number you turn it up to is the coldest
But is probably a common defrost problem The ice build up
is not being melted by the defrost system.The fan can't blow through the coils into the fridge.
Take out back panel of freezer to check for ice buildup. The coils should be clean.
There are three components to a defrost system- a heater,heater thermostat, and a timer unless you have a defrost electronic card.
Its best handled by a Technician but you could possibly do it by taking your model number to the nearest appliance parts store and asking for the parts. They are mostly located in freezer ,behind back panel on freezer coils.except the card which is usually located in ref The parts store will have info
Also check fan undernearh Ref in the rear
Clean condenser coils underneath
Make sure back cover is on the fridge. Some take them off and throw them away.
make one out of cardboard if its gone, using the holes of the old one.
.I'm including my article on Refrigerator Repair for your help and convenience.;
Please click or copy and paste into browser for Article

http://www.fixya.com/support/r5816737-fix_refrigerator_psychologically

If you need more help go here:

http://www.applianceaid.com/procedures.html

MORE
TIPS AND TRICKS:
-----------------------------------------------------------------------------------------------------
STOP PAYING FOR EXPENSIVE WATER FILTERS FOR YOUR REF. DO THIS====
http://www.fixya.com/support/r9962087-stop_paying_high_price_refrigerator
-------------------------------------------------------------------------------------------------------
WATER SPLASHING IN FREEZER AT ICEMAKER
THE FILL TUBE IN BACK OF REFRIGERATOR CAN SLIP
AGAINST THE FILL RESERVOIR CAUSING A PARTIAL BLOCKAGE
OR BECOME CLOGGED WITH ICE.
REMOVE THE ICEMAKER AND INSPECT THE FILL TUBE.
RUN WATER IN TUBE TO ELININATE BLOCKAGE AND CHECK
TEMP IN FREEZER. IF TEMP IS BELOW 0 DEGREES, THATS
OVERKILL AND USUALLY A WASTE OF ELECTRICITY TO KEEP IT THAT COLD, NOT TO MENTION THE FILL TUBE FREEZING UP
----------------------------------------------------------------------------------------------------------------------
Thanks for using fixya
Leo Ponder
imufo2
Please VOTE FOR ME AND GIVE ME YOUR TESTIMONIAL IF POSSIBLE, IF THIS WAS HELPFUL
ITWILL BE MUCH APPRECIATED.
9/24/2011 2:51:56 PM • Whirlpool 25.4... • Answered on Sep 24, 2011
0helpful
1answer

Ice maker is not getting water to make ice

Hello there,
When your ice maker is not getting water into it, it simply means the water inlet valve is clooged with dirt and have blocked the valve from getting water into the ice maker.
Your icemaker's water inlet valve could be filled with ice. If it is, simply thaw the its water tube with a hair dryer to remove the blockage. Be careful to not melt any plastic parts with the blow dryer. An icemaker's water inlet valve has a filtering screen to block minerals and other debris from entering into your ice cubes. It is possible that the water inlet valve's screen is blocked, and not allowing any water through to make ice. Clean out any built up debris you find. You should be able to pop the screen out of place with a screwdriver and then put it back in place with the screwdriver again once it is cleaned.
Alternatively, the water inlet valve itself may have become defective. You will have to test it. If the test proves the valve is defective, replace it.
Hope this helped. All the best Elect_Comp
9/23/2011 1:12:50 PM • Whirlpool 25.4... • Answered on Sep 23, 2011
0helpful
2answers

Refrigerator is to warm,freezer to cold model is

In most cases something has blocked the vent from the freezer. Sometimes you catch this at a point that the freezer seems too cold but just what may be happening is the ADC control has failed causing the evaporator to freeze over with frost blocking air flow to the fresh food section. The ADC is Adaptive Defrost Control and can be forund here=> ED5GHEXNL00 Fresh Food Section Controls in that photo location 6 is the ADC or defrost control board=> W10353224 Defrost Control Board If you disconnect refrigerator from power source and lower control panel you can look this board over on both sides. Sometimes you will see burn marks or signs of heat damage, not always.

sea_breeze_243.jpg
Second most Likely is the defrost heater behind the rear wall of your freezer=> ED5GHEXNL00 Unit Parts and in that photo part location 33 is the=> 2188175 Defrost Heater Assembly

sea_breeze_244.jpg
Ways to test this heater are on same page. Then we always need to consider the defrost thermostat found here=> ED5GHEXNL00 Air Flow Parts item 6 in that photo. At -5 to +5 degrees the contacts inside should be closed and once the freezer goes into defrost the defrost thermostat opens its contacts at 50 degrees to prevent extended defrost. Part Number=> 2321799 Look inside rear of the freezer and if a layer of frost is building on rear wall then you most likely have a defrost problem causing the freezer to be colder. If fan in freezer is working properly then you should have a steady stream of cold air flowing to the fresh food compartment. Let me know just what you find so I may assist you in the repair, Thanks, Sea Breeze
9/22/2011 3:58:01 AM • Whirlpool 25.4... • Answered on Sep 22, 2011
0helpful
1answer

My ice maker stopped working and the red light is

NOTE: This
is a multi-solution answer since I don't have all the tech from your question to pinpoint your problem
But the solution is in here generically, if you read and study the solutions very,very carefully.
Check Temp inside freezer. It has to be down to about 10 or 15 degrees
This can cause slow ice making if its too high even tho its freezing everything else at 25 degrees
The ref. temp should be about 33-35
The Freezer temp should be 0 to 10 Any thing below these temps is overkill and a waste of elect
The higher the number you turn it up to is the coldest
The icemaker is 110v
See if water is in icemaker.
Pour water in Ice Maker and wait to see if it ejects.
If it ejects thenyou need to replace water valve in rear bottom of fridge(Its the part that
attaches to water line out of wall)
If it doesn't eject then it is a faulty Ice Maker.
If its leaking or no water at icemaker or door either one, then the valve at the rear bottom of ref needs replacing
I would check the fan in the freezer. Listen to see if it is running
It moves air to the ref from the freezer
Then check to see if freezer control is turned WARMER, which makes the Ref. colder
Also if it is getting drinking water to the door but not to the icemaker (or vice versa) Then you need to replace
the water valve at the bottom rear of the fridge. It is a double valve and one side is not working
Also this might be a common Defrost problem, Ice
is not being melted by the defrost system.The fan can't blow through the coils into the fridge.
Take out back panel of freezer to check for ice buildup. The coils should be clean.
There are three components to a defrost system- a heater,heater thermostat, and a timer unless you have a defrost electronic card.
Its best handled by a Technician but you could possibly do it by taking your model number to the nearest appliance parts store and asking for the parts. They are mostly located in freezer ,behind back panel on freezer coils.except the card which is usually located in ref The parts store will have info
Also check fan undernearh Ref in the rear
Clean condenser coils underneath
WATER SPLASHING IN FREEZER AT ICEMAKER
THE FILL TUBE IN BACK OF REFRIGERATOR CAN SLIP
AGAINST THE FILL RESERVOIR CAUSING A PARTIAL BLOCKAGE
OR BECOME CLOGGED WITH ICE.
REMOVE THE ICEMAKER AND INSPECT THE FILL TUBE.
RUN WATER IN TUBE TO ELININATE BLOCKAGE AND CHECK
TEMP IN FREEZER. IF TEMP IS BELOW 0 DEGREES, THATS
OVERKILL AND USUALLY A WASTE OF ELECTRICITY TO KEEP IT THAT COLD, NOT TO MENTION THE FILL TUBE FREEZING UP
If you still have trouble GO HERE:

hhttp://www.applianceaid.com/procedures.htm

I'm including my article on Refrigerator Repair for your help and convenience.;
Please click or copy and paste into browser for Article

http://www.fixya.com/support/r5816737-fix_refrigerator_psychologically

Thanks for using fixya
Leo Ponder
imufo2
PLEASE GIVE A TESTIMONIAL AND VOTE FOUR THUMBS UP IF THIS WAS HELPFUL
9/20/2011 4:50:39 AM • Whirlpool 25.4... • Answered on Sep 20, 2011
0helpful
1answer

MAKING ICE, NO WATER TO DOOR , IS THERE A RESET

NOTE: This
is a multi-solution answer since I don't have all the tech from your question to pinpoint your problem
But the solution is in here generically, if you read and study the solutions very,very carefully.
Check Temp inside freezer. It has to be down to about 10 or 15 degrees
This can cause slow ice making if its too high even tho its freezing everything else at 25 degrees
The ref. temp should be about 33-35
The Freezer temp should be 0 to 10 Any thing below these temps is overkill and a waste of elect
The higher the number you turn it up to is the coldest
The icemaker is 110v
See if water is in icemaker.
Pour water in Ice Maker and wait to see if it ejects.
If it ejects thenyou need to replace water valve in rear bottom of fridge(Its the part that
attaches to water line out of wall)
If it doesn't eject then it is a faulty Ice Maker.
If its leaking or no water at icemaker or door either one, then the valve at the rear bottom of ref needs replacing
I would check the fan in the freezer. Listen to see if it is running
It moves air to the ref from the freezer
Then check to see if freezer control is turned WARMER, which makes the Ref. colder
Also if it is getting drinking water to the door but not to the icemaker (or vice versa) Then you need to replace
the water valve at the bottom rear of the fridge. It is a double valve and one side is not working
Also this might be a common Defrost problem, Ice
is not being melted by the defrost system.The fan can't blow through the coils into the fridge.
Take out back panel of freezer to check for ice buildup. The coils should be clean.
There are three components to a defrost system- a heater,heater thermostat, and a timer unless you have a defrost electronic card.
Its best handled by a Technician but you could possibly do it by taking your model number to the nearest appliance parts store and asking for the parts. They are mostly located in freezer ,behind back panel on freezer coils.except the card which is usually located in ref The parts store will have info
Also check fan undernearh Ref in the rear
Clean condenser coils underneath
If you still have trouble GO HERE:

hhttp://www.applianceaid.com/procedures.htm

I'm including my article on Refrigerator Repair for your help and convenience.;
Please click or copy and paste into browser for Article

http://www.fixya.com/support/r5816737-fix_refrigerator_psychologically

Thanks for using fixya
Leo Ponder
imufo2
PLEASE GIVE A TESTIMONIAL AND VOTE FOUR THUMBS UP IF THIS WAS HELPFUL
9/19/2011 10:02:11 AM • Whirlpool 25.4... • Answered on Sep 19, 2011
0helpful
1answer

Whirlpool side by side 6th

NOTE: This
is a multi-solution answer since I don't have all the tech from your question to pinpoint your problem
But the solution is in here generically, if you read and study the solutions very,very carefully.
First I would check cold control. Thats where you turn it off, if your temp is not warm. it can
be defective and not shutting off. If your temp is warm proceed with the following.
I would check the fan in the freezer. Listen to see if it is running
It moves air to the ref from the freezer
Then check to see if FREEZER CONTROL is turned WARMER WHICH MAKES THE REF COLDER AND VICE-VERSA. SEE?
The ref. temp should be about 33-35
The Freezer temp should be 0 to 10 Any thing below these temps is overkill and a waste of elect
The higher the number you turn it up to is the coldest
But is probably a common defrost problem The ice build up
is not being melted by the defrost system.The fan can't blow through the coils into the fridge.
Take out back panel of freezer to check for ice buildup. The coils should be clean.
There are three components to a defrost system- a heater,heater thermostat, and a timer unless you have a defrost electronic card.
Its best handled by a Technician but you could possibly do it by taking your model number to the nearest appliance parts store and asking for the parts. They are mostly located in freezer ,behind back panel on freezer coils.except the card which is usually located in ref The parts store will have info
Also check fan undernearh Ref in the rear
Clean condenser coils underneath
Make sure back cover is on the fridge. Some take them off and throw them away.
make one out of cardboard if its gone, using the holes of the old one.
.I'm including my article on Refrigerator Repair for your help and convenience.;
Please click or copy and paste into browser for Article

http://www.fixya.com/support/r5816737-fix_refrigerator_psychologically

If you need more help go here:

http://www.applianceaid.com/procedures.html

MORE
TIPS AND TRICKS:
-----------------------------------------------------------------------------------------------------
STOP PAYING FOR EXPENSIVE WATER FILTERS FOR YOUR REF. DO THIS====
http://www.fixya.com/support/r9962087-stop_paying_high_price_refrigerator
-------------------------------------------------------------------------------------------------------
WATER SPLASHING IN FREEZER AT ICEMAKER
THE FILL TUBE IN BACK OF REFRIGERATOR CAN SLIP
AGAINST THE FILL RESERVOIR CAUSING A PARTIAL BLOCKAGE
OR BECOME CLOGGED WITH ICE.
REMOVE THE ICEMAKER AND INSPECT THE FILL TUBE.
RUN WATER IN TUBE TO ELININATE BLOCKAGE AND CHECK
TEMP IN FREEZER. IF TEMP IS BELOW 0 DEGREES, THATS
OVERKILL AND USUALLY A WASTE OF ELECTRICITY TO KEEP IT THAT COLD, NOT TO MENTION THE FILL TUBE FREEZING UP
----------------------------------------------------------------------------------------------------------------------
Thanks for using fixya
Leo Ponder
imufo2
Please VOTE FOR ME AND GIVE ME YOUR TESTIMONIAL IF POSSIBLE, IF THIS WAS HELPFUL
ITWILL BE MUCH APPRECIATED.
9/19/2011 9:57:38 AM • Whirlpool 25.4... • Answered on Sep 19, 2011
0helpful
1answer

Our ice maker frozen. Do we need to remove the

NOTE: This
is a multi-solution answer since I don't have all the tech from your question to pinpoint your problem
But the solution is in here generically, if you read and study the solutions very,very carefully.
Check Temp inside freezer. It has to be down to about 10 or 15 degrees
This can cause slow ice making if its too high even tho its freezing everything else at 25 degrees
The ref. temp should be about 33-35
The Freezer temp should be 0 to 10 Any thing below these temps is overkill and a waste of elect
The higher the number you turn it up to is the coldest
The icemaker is 110v
See if water is in icemaker.
Pour water in Ice Maker and wait to see if it ejects.
If it ejects thenyou need to replace water valve in rear bottom of fridge(Its the part that
attaches to water line out of wall)
If it doesn't eject then it is a faulty Ice Maker.
If its leaking or no water at icemaker or door either one, then the valve at the rear bottom of ref needs replacing
I would check the fan in the freezer. Listen to see if it is running
It moves air to the ref from the freezer
Then check to see if freezer control is turned WARMER, which makes the Ref. colder
Also if it is getting drinking water to the door but not to the icemaker (or vice versa) Then you need to replace
the water valve at the bottom rear of the fridge. It is a double valve and one side is not working
Also this might be a common Defrost problem, Ice
is not being melted by the defrost system.The fan can't blow through the coils into the fridge.
Take out back panel of freezer to check for ice buildup. The coils should be clean.
There are three components to a defrost system- a heater,heater thermostat, and a timer unless you have a defrost electronic card.
Its best handled by a Technician but you could possibly do it by taking your model number to the nearest appliance parts store and asking for the parts. They are mostly located in freezer ,behind back panel on freezer coils.except the card which is usually located in ref The parts store will have info
Also check fan undernearh Ref in the rear
Clean condenser coils underneath
If you still have trouble GO HERE:

hhttp://www.applianceaid.com/procedures.htm

I'm including my article on Refrigerator Repair for your help and convenience.;
Please click or copy and paste into browser for Article

http://www.fixya.com/support/r5816737-fix_refrigerator_psychologically

Thanks for using fixya
Leo Ponder
imufo2
PLEASE GIVE A TESTIMONIAL AND VOTE FOUR THUMBS UP IF THIS WAS HELPFUL
9/19/2011 3:13:28 AM • Whirlpool 25.4... • Answered on Sep 19, 2011
0helpful
1answer

My fridge has a Beeping sound for the past 24Hours

NOTE: This
is a multi-solution answer since I don't have all the tech from your question to pinpoint your problem
But the solution is in here generically, if you read and study the solutions very,very carefully.
First I would check cold control. Thats where you turn it off, if your temp is not warm. it can
be defective and not shutting off. If your temp is warm proceed with the following.
I would check the fan in the freezer. Listen to see if it is running
It moves air to the ref from the freezer
Then check to see if FREEZER CONTROL is turned WARMER WHICH MAKES THE REF COLDER AND VICE-VERSA. SEE?
The ref. temp should be about 33-35
The Freezer temp should be 0 to 10 Any thing below these temps is overkill and a waste of elect
The higher the number you turn it up to is the coldest
But is probably a common defrost problem The ice build up
is not being melted by the defrost system.The fan can't blow through the coils into the fridge.
Take out back panel of freezer to check for ice buildup. The coils should be clean.
There are three components to a defrost system- a heater,heater thermostat, and a timer unless you have a defrost electronic card.
Its best handled by a Technician but you could possibly do it by taking your model number to the nearest appliance parts store and asking for the parts. They are mostly located in freezer ,behind back panel on freezer coils.except the card which is usually located in ref The parts store will have info
Also check fan undernearh Ref in the rear
Clean condenser coils underneath
Make sure back cover is on the fridge. Some take them off and throw them away.
make one out of cardboard if its gone, using the holes of the old one.
.I'm including my article on Refrigerator Repair for your help and convenience.;
Please click or copy and paste into browser for Article

http://www.fixya.com/support/r5816737-fix_refrigerator_psychologically

If you need more help go here:

http://www.applianceaid.com/procedures.html

MORE
TIPS AND TRICKS:
-----------------------------------------------------------------------------------------------------
STOP PAYING FOR EXPENSIVE WATER FILTERS FOR YOUR REF. DO THIS====
http://www.fixya.com/support/r9962087-stop_paying_high_price_refrigerator
-------------------------------------------------------------------------------------------------------
WATER SPLASHING IN FREEZER AT ICEMAKER
THE FILL TUBE IN BACK OF REFRIGERATOR CAN SLIP
AGAINST THE FILL RESERVOIR CAUSING A PARTIAL BLOCKAGE
OR BECOME CLOGGED WITH ICE.
REMOVE THE ICEMAKER AND INSPECT THE FILL TUBE.
RUN WATER IN TUBE TO ELININATE BLOCKAGE AND CHECK
TEMP IN FREEZER. IF TEMP IS BELOW 0 DEGREES, THATS
OVERKILL AND USUALLY A WASTE OF ELECTRICITY TO KEEP IT THAT COLD, NOT TO MENTION THE FILL TUBE FREEZING UP
----------------------------------------------------------------------------------------------------------------------
Thanks for using fixya
Leo Ponder
imufo2
Please VOTE FOR ME AND GIVE ME YOUR TESTIMONIAL IF POSSIBLE, IF THIS WAS HELPFUL
ITWILL BE MUCH APPRECIATED.
9/16/2011 6:21:48 AM • Whirlpool 25.4... • Answered on Sep 16, 2011
Not finding what you are looking for?
Whirlpool 25.4 Cu. Ft. Side-by-Side Refrigerator w/Thru-the-Door Ice & Water - Satina Stainless-Look Logo

369 questions posted

Ask a Question

Usually answered in minutes!

Top Whirlpool Refrigerators Experts

Mike Cairns
Mike Cairns

Level 3 Expert

3054 Answers

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Brad Brown

Level 3 Expert

19187 Answers

Are you a Whirlpool Refrigerator Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

View Most Popular

Whirlpool Refrigerators

  • Whirlpool Refrigerators

Most Popular Question

knocking noise about every hour or

  • Refrigerators
Loading...