U-Line Icemaker - Answered Questions & Fixed issues

0helpful
1answer

U-Line Echelon CLR2060 Ice machine doesnt harvest properly

No where can I find anyone who has solved Uline Echelon ice maker harvesting issues. My Clr 2060 only now produces 1" solid slabs. In harvesting cycle, will not release individual cubes. Anyone fix this problem? vlog
6/4/2023 5:34:55 PM • U-Line Icemaker • Answered on Jun 04, 2023 • 474 views
0helpful
1answer

BCM 95. Why is there no condenser fan or compressor activation when turned on?

because it is an automatic machine
3/24/2021 7:33:17 PM • U-Line Icemaker • Answered on Mar 24, 2021 • 91 views
0helpful
2answers

How to install an icemaker water supply line over concrete floor?

IM USE A 1/4 INCH WATER LINE LOOK FOR A SINK OR WASHER CLOUSE BY AND ATACH TO THE HOT WATER LIND IF YOU HAVE LIME IN YOUR STATE IF NOT USE THE COLD WATER RUNTHE HOSE INSIDE THE CAVINET TO HIDE THE HOSE.
9/28/2022 7:37:04 PM • U-Line Icemaker • Answered on Sep 28, 2022 • 3,054 views
0helpful
2answers

After a power outage the ice maker stopped

Tell him to first fill ref-regent gas in compressor cause if does not have enough the comp will over heat a cut of .
7/26/2020 4:49:30 AM • U-Line Icemaker • Answered on Jul 26, 2020 • 1,459 views
0helpful
1answer

I have a Uline model SP18 ice maker.Recently the

It does sound as if you may need a new ice maker. Other than that does the compressor come on to keep the ice cold? If so is it making any type of noises beyond the typical hum?
6/10/2017 7:46:33 PM • U-Line Icemaker • Answered on Jun 10, 2017 • 702 views
0helpful
1answer

Purchased magic chef counter top

Sorry we do not sell this product or any other. Please contact the manufacturer.
4/21/2017 5:46:52 PM • U-Line Icemaker • Answered on Apr 21, 2017 • 169 views
0helpful
1answer

I HAVE A 2 YR OLD U-LINE ICE MAKER MODEL B12115 TH...

Follow this link. This should help with your uline not making Ice. line ice maker model ULN B12115 not making ice
8/1/2016 12:54:29 AM • U-Line Icemaker • Answered on Aug 01, 2016 • 1,914 views
0helpful
1answer

U line ice maker is overflowing water

This is usually caused by a bad water inlet valve. This part is usually found behind the fridge at the bottom behind a panel on the fridge itself. It has 1-2 water lines running into it and 1-2 wire harnesses connected. You need to turn off the water going into the fridge and cut the power to the fridge to access this part. You can buy a new one at a local appliance parts store or online. If you need further help, I’m available over the phone at https://www.6ya.com/expert/rick_b814bade9ade93ea
4/19/2016 4:45:00 PM • U-Line Icemaker • Answered on Apr 19, 2016 • 1,657 views
0helpful
1answer

My BI95 ice maker freezes and has water flow, the mould maker fills, the water continues to run into the bucket and it freezes solid. I changed the mould maker and water valve. The problem remains

If water keeps running after the fill cycle is usually indicates a bad fridge inlet valve. This valve controls the amount of water going into your icemaker. It is found where the water line goes into the fridge, usually in the back of the fridge at the bottom. You would need to cut the power to the fridge, turn off the water supply going into the fridge and remove a panel to get to it. You can check out online what a fridge water inlet valve looks like so you can identify it. It usually has 1-2 water lines going into it and 1-2 wire harnesses attached. You can buy new ones at a appliance parts store or online. If you need further help, I’m available over the phone at https://www.6ya.com/expert/rick_b814bade9ade93ea
4/19/2016 4:40:10 PM • U-Line Icemaker • Answered on Apr 19, 2016 • 760 views
0helpful
1answer

Water in back of ice tube and in with ice cubes freezes

leaking water tray or water level to high check for any cracks and check water level after first harvest
2/3/2016 8:04:31 PM • U-Line Icemaker • Answered on Feb 03, 2016 • 777 views
0helpful
1answer

How do you change the water valve?

The water valve is normally situated at the bottom rear of the fridge. Follow the water line/ hose to the inside of the fridge at the back compartment and you will find it. With the water AND the power unplugged / turned off, you can remove the water hose fittings and there is usually only 2 wires to the valve.. The water valve itself should only be mounted with a couple of screws or on a bracket. refit everything with the new valve. Slowly turn the water back on first and make sure there are no leaks.
5/26/2015 4:02:25 PM • U-Line Icemaker • Answered on May 26, 2015 • 452 views
0helpful
1answer

Unit gets cold but water pours thru without freezing. what could be the problem?

Possible water valve leaking thru
5/26/2015 7:00:14 PM • U-Line Icemaker • Answered on May 26, 2015 • 1,029 views
0helpful
1answer

Model No. unknown (believe it's a CLR-5+ years old with manual switch for on/off/cln cycles) will run in clean cycle, but stopped making ice. Ran cleaning cycle when it stopped making ice - worked per

After the cleaning cycle, if you drained the tank to get rid of the cleaning/descaling solution, you will have to refill the machine for the initial start. The normal freeze/ harvest cycle will normally fill the unit after the initial start. I have seen several ice makers with this same initial problem. If this is not the case and your reservoir is full of water, then check water supply to make sure water will flow all the way into the reservoir. Sometimes the makeup water solenoid fails and need replaced. So if cleaning cycle works and fills, solenoid operated water valve is not the problem. If would mean some electric component is not working. The on/off/clean switch not sending on signal. The board, which is located under the top panel of the cabinet, may have a bad contact on the board. Another possibility is the water level sensor may not be in contact with the water. Most units will not start if the water sensor is not in contact with the water level. It normally looks like a metal probe and has a wire connecting to it to the control board. Any parts can be found by taking your model number to Searspartsdirect.com and can be ordered using a credit card and be delivered to your home. Hope this helps
3/4/2015 1:41:09 AM • U-Line Icemaker • Answered on Mar 04, 2015 • 436 views
0helpful
1answer

Water leaking from ice maker

Make sure normal drain line (located under the ice) is not clogged. Check gaskets and seals. Also make sure everyone who uses it closes the door completely and does not leave it cracked open. And make sure no one has screwed any thing into it and punctured through it. A screw alone will not keep the water in.
2/25/2015 5:30:10 PM • U-Line Icemaker • Answered on Feb 25, 2015 • 872 views
0helpful
1answer

How do I open the machine control panel side and cube adjustable thermostat

What's the make and model. ..maybe mechanical
1/16/2015 12:03:12 AM • U-Line Icemaker • Answered on Jan 16, 2015 • 180 views
0helpful
1answer

Condenser freezes up. Then won't cool. Why?

Sounds like you could be over or under charged
1/15/2015 3:26:36 AM • U-Line Icemaker • Answered on Jan 15, 2015 • 145 views
0helpful
3answers

U-line CLR2160 won't go into clean cycle. I hold the power button while pressing the light button 3 times.

I had to hold Power for 10+ seconds (until last "F" flashes, quickly let go of Power, then press and hold it again and while holding it pres the light three times.The process doesn't follow the manual's instructions at all. Their older model units with the physical on/off/clean selector switch was much more reliable than their new 2160 with touch screen controls!
9/19/2022 11:40:44 AM • U-Line Icemaker • Answered on Sep 19, 2022 • 3,441 views
0helpful
1answer

Uline ice maker parts gasket part no. 3002

Most door gaskets can bought from a roll at appliance parts dealers, or: www.appliancepartsonline.net
12/25/2014 2:25:51 PM • U-Line Icemaker • Answered on Dec 25, 2014 • 117 views
0helpful
1answer

Seems like my icemaker overflows when filling. I have an ice build up around the plastic box. How can I adjust water

There is not an adjustment. The ice maker dump arm has a cam on it that engages the water fill switch. switch is bad or ice maker motor has a bad spot in it .
11/26/2014 12:21:35 PM • U-Line Icemaker • Answered on Nov 26, 2014 • 742 views
0helpful
1answer

Water keeps running in ice maker

Turn off the machine if water is still running then unplug the machine. If the water is still running then check water presser from water supply to make sure it is under 80 psi before replacing water inlet valve.
11/26/2014 12:10:51 PM • U-Line Icemaker • Answered on Nov 26, 2014 • 4,100 views
Not finding what you are looking for?
U-Line Icemaker Logo

489 questions posted

Ask a Question

Usually answered in minutes!

Top U-Line Kitchen Appliances - Others Experts

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

john h

Level 3 Expert

29494 Answers

Brad Brown

Level 3 Expert

19187 Answers

Are you an U-Line Kitchen Appliances - Other Expert? Answer questions, earn points and help others

Answer questions