I have an Amana through

Bad thermostat or temp sensor.
8/3/2017 12:41:13 AM • Amana... • Answered on Aug 03, 2017 • 200 views
0helpful
3answers

Looking for manuel reset on heater amana ptac

I dont know about this model but in general electric heat wont have a reset button the heat is controled by a sequencer and each elememt has a safty limit switch incase the sequencer sticks in the on mode here is a link to where you can get more info on this model http://www.fixya.com/support/p51773-amana_ptc153b35aj_air_conditioner
11/21/2016 3:43:55 PM • Amana... • Answered on Nov 21, 2016 • 5,391 views
0helpful
1answer

I have an Amana PTAC ac 15000 BTU that has stopped, the power cord keeps tripping. I removed the power cord and plugged it in to the socket and the breaker did not trip, any clues. I'm thinking of jus

I think you've gotton your moneys worth with ten trouble free years. The power cords safety device is a bit more sensitive to a high resistive short to ground than your breaker is. I would suggest that there is exactly that: a high resistive short to ground within the cabinet of the PTAC. It has been years since I have been on a PTAC call and am unable to suggest specifics. But if you are competent and capable of using a DVOM, open up the unit and begin a systematic approach of determining the problem. The FIRST thing I'd do is check the motor and the compressor with a digital megohmeter. Sometimes their problem will only show up with this sensitive device.
6/16/2015 2:22:12 PM • Amana... • Answered on Jun 16, 2015 • 1,198 views
0helpful
1answer

Heat won't come on

If it is a reverse cycle unit the magnetic reverse cycle switch is faulty and should be replaced
5/16/2014 4:43:27 AM • Amana... • Answered on May 16, 2014 • 168 views
0helpful
1answer

What does diagnostic code lf mean

1blink/sec---normal, 2blink/sec--blown fuse--3bliks/sec--replace evaporator sensor,4blinks/sec--mode switch failure, replace board,5blinks/sec--pot. failure,replace board;6blinks/sec--bad thermostat input; 7blinks/sec--factory only;8blinks/sec--bad room thermostat. The blink pattern repeats every 5 seconds.
2/2/2013 3:43:24 AM • Amana... • Answered on Feb 02, 2013 • 436 views
0helpful
1answer

My tenant alleges that the excessive amount of

OK, so what's your question? Unfortunately, I can't answer it, if I don't know what it is.
8/15/2011 7:18:52 PM • Amana... • Answered on Aug 15, 2011 • 72 views
0helpful
1answer

NO POWER TO CONTROL PANEL ,NOTHING COMES ON

Check your breaker see if its tripped
6/22/2011 6:21:19 PM • Amana... • Answered on Jun 22, 2011 • 127 views
0helpful
1answer

Model PTC153B35AJ Fan motor is seized! How do you

It's due to bearing struck. Remove motor and replace bearings, if the windings are good. If not you have replace motor only. Call repairman nearest to you. Thanks.
1/16/2011 6:16:31 AM • Amana... • Answered on Jan 16, 2011 • 57 views
0helpful
1answer

I have no 220 coming out of the circuit board heat

Jumping 220 volts directly to heat or cool for just checking purpose. Not for regular use. Please replace your thermostat immediately.Please don't take risk.
To get heat set temp 30 degree and mode in "Heat"Hope you will keep my sincere advise.
1/14/2011 11:04:37 AM • Amana... • Answered on Jan 14, 2011 • 83 views
0helpful
1answer

Amana ptc153b50aj is not putting out any heat

1. Check compressor is working. 2. confirm no loose contacts. 3. Keep mode " in Heat" 4. Temp setting +5 degree than your room temp.
12/28/2010 2:07:53 AM • Amana... • Answered on Dec 28, 2010 • 219 views
0helpful
1answer

I have an Amana Model PTH15-350A through the wall

it mite be time to change that unit for a new one or you can have a service person come out and look it at it
12/27/2010 3:33:24 PM • Amana... • Answered on Dec 27, 2010 • 219 views
0helpful
1answer

Amana80 SSE Air Command Gas

Hello and sorry to hear about your problem.
It sounds like your glow rod, is defective. This is the electronic pilot lite for the unit.
I suggest you can in a service person. If you live in the Denver Co area, I can help you.

I have tried to help you. Please help me by Vote/Rate this response. Thanks and good luck.
34234jiii
12/21/2010 8:24:58 PM • Amana... • Answered on Dec 21, 2010 • 517 views
0helpful
1answer

Amana Model PTH153A50AC wont cool or heat

Hi,
Here is a tip about trouble shooting your air conditioner...

Air Conditioner Trouble -Review the Possibilities
http://www.fixya.com/support/r3571569-air_conditioner_trouble_review_the_possi

heatman101
7/12/2010 2:28:46 AM • Amana... • Answered on Jul 12, 2010 • 852 views
0helpful
1answer

Ac went under water, in 2005 havenot used it since,

I would be 'surprised' if this motor would ever run again, cleaned or not cleaned.

I suggest you look into buying a new/different AC unit.

good luck!
5/4/2010 5:22:01 PM • Amana... • Answered on May 04, 2010 • 48 views
0helpful
1answer

HOW DO RESET LIMIT SWITCH

The limit switch will have a small button in the middle. Push to reset. If no button and limit is open. Bad switch. Replace it. Russ
3/25/2010 2:29:30 PM • Amana... • Answered on Mar 25, 2010 • 366 views
0helpful
1answer

I have a amana airhandler heatpump air unit that

replace the ptac board
1/24/2010 8:26:18 PM • Amana... • Answered on Jan 24, 2010 • 123 views
0helpful
1answer

My Amana Confort Zone ptac unit with model number

there is a drain plug inside unit.pull unit out of hole and look down to right side of unit in the drain pan you will see a plastic drain port knock it out and the unit will drain
1/24/2010 8:20:58 PM • Amana... • Answered on Jan 24, 2010 • 503 views
0helpful
1answer

I had the turned on this morning but it will no

Do you have power going to it?. Sometimes if a cheap outlet is used it will break the connection when a loasd is put on it. With the unit plugged in and in on position, wiggle the cord st the outlet. Confirm you have power to the AC Unit, Let me know.
11/7/2009 9:36:04 PM • Amana... • Answered on Nov 07, 2009 • 144 views
0helpful
1answer

Excessive water dripping from Central A/C drian line

sounds like the overflow drain is picking up the water that means the main drain is clogged.you need to find the main drain pipe if lookin at the air handler in attic there should be 2 drains from unit one higher than other follow it and blow out drain they put the other overflow drain out the eve so if it stars leaking someone notices it and it doesnt damage cieling but it sound like it needs imediate attention befor it does go to the overflow pan and damage your cieling. i hope this helps and good luck
7/3/2013 2:07:57 AM • Amana... • Answered on Jul 03, 2013 • 1,369 views
0helpful
1answer

Rusted drip pan

it is call a base pan part #20403508..
let me know if it helps
9/23/2009 1:23:09 AM • Amana... • Answered on Sep 23, 2009 • 62 views
Not finding what you are looking for?
Amana PTC153B35AJ Air Conditioner Logo

43 questions posted

Ask a Question

Usually answered in minutes!

Top Amana Heating & Cooling Experts

Mike Cairns
Mike Cairns

Level 3 Expert

3054 Answers

Jay Finke
Jay Finke

Level 3 Expert

1397 Answers

Cindy Wells

Level 3 Expert

6688 Answers

Are you an Amana Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...