Amana PTC153B35AJ Air Conditioner Questions & Answers
Heat won't come on
If it is a reverse cycle unit the magnetic reverse cycle switch is faulty and should be replaced
11/27/2013 4:29:31 PM •
Amana...
•
168 views • 0 helpful votes
What does diagnostic code lf mean
1blink/sec---normal, 2blink/sec--blown fuse--3bliks/sec--replace evaporator sensor,4blinks/sec--mode switch failure, replace board,5blinks/sec--pot. failure,replace board;6blinks/sec--bad thermostat input; 7blinks/sec--factory only;8blinks/sec--bad room thermostat. The blink pattern repeats every 5 seconds.
1/13/2013 9:22:49 AM •
Amana...
•
435 views • 0 helpful votes
Amana80 SSE Air Command Gas
Hello and sorry to hear about your problem.
It sounds like your glow rod, is defective. This is the electronic pilot lite for the unit.
I suggest you can in a service person. If you live in the Denver Co area, I can help you.
I have tried to help you. Please help me by Vote/Rate this response. Thanks and good luck.
34234jiii
12/21/2010 8:19:52 PM •
Amana...
•
517 views • 1 helpful votes
I have no 220 coming out of the circuit board heat
Jumping 220 volts directly to heat or cool for just checking purpose. Not for regular use. Please replace your thermostat immediately.Please don't take risk.
To get heat set temp 30 degree and mode in "Heat"Hope you will keep my sincere advise.
1/13/2011 9:57:35 PM •
Amana...
•
83 views • 0 helpful votes
Won't heat and doesn't cool properly
Hi, from the above explanation, it is seems to be a thermostat or board problem just like the previous person told you and the price to replace the affected part is expensive because it's old fashioned and the parts are scares to get. The thermostat should be around $150 or less if that is the problem but the board is within the price range you were told.
Take care
6/20/2010 10:56:04 PM •
Amana...
•
61 views • 1 helpful votes
HOW DO RESET LIMIT SWITCH
The limit switch will have a small button in the middle. Push to reset. If no button and limit is open. Bad switch. Replace it. Russ
3/25/2010 12:06:59 PM •
Amana...
•
366 views • 0 helpful votes
Excessive water dripping from Central A/C drian line
sounds like the overflow drain is picking up the water that means the main drain is clogged.you need to find the main drain pipe if lookin at the air handler in attic there should be 2 drains from unit one higher than other follow it and blow out drain they put the other overflow drain out the eve so if it stars leaking someone notices it and it doesnt damage cieling but it sound like it needs imediate attention befor it does go to the overflow pan and damage your cieling. i hope this helps and good luck
9/29/2009 3:01:10 AM •
Amana...
•
1,369 views • 1 helpful votes
I had the turned on this morning but it will no
Do you have power going to it?. Sometimes if a cheap outlet is used it will break the connection when a loasd is put on it. With the unit plugged in and in on position, wiggle the cord st the outlet. Confirm you have power to the AC Unit, Let me know.
11/7/2009 9:28:01 PM •
Amana...
•
144 views • 0 helpful votes
My Amana Confort Zone ptac unit with model number
there is a drain plug inside unit.pull unit out of hole and look down to right side of unit in the drain pan you will see a plastic drain port knock it out and the unit will drain
8/15/2009 10:29:29 PM •
Amana...
•
503 views • 1 helpful votes