20 Most Recent Comfort-Aire BHD-501 Dehumidifier - Page 3 Questions & Answers

0helpful
1answer

Unit shuts down after running just a few

Hi,

Kindly Confirm the Make and Model of the Dehumidifier?

Let me know,so that we could Proceed.

Hope i helped you.

Thanks for using ' Fixya ' and have a nice day!!
5/26/2010 2:40:53 PM • Comfort-Aire... • Answered on May 26, 2010
0helpful
1answer

This dehumidifier does not seem to removing any

Hi,
Here is a tip that I wrote about that problem...

http://www.fixya.com/support/r4662409-dehumidifier_running_but_no_water_in

heatman101
4/30/2010 3:39:35 AM • Comfort-Aire... • Answered on Apr 30, 2010
0helpful
1answer

My dehumidifier doesn't seem to be removing any

Hi,
Here is a tip that will help you with basic trouble shooting..

http://www.fixya.com/support/r3877515-dehumidifier_problems_dehumidifier

heatman101
4/28/2010 12:30:33 PM • Comfort-Aire... • Answered on Apr 28, 2010
0helpful
1answer

Dehumidifier is on but nothing happens

air filter clean.
water level switch problem.
control card problem
start at these points first........
if fan is working may be compressor.
4/21/2010 10:26:08 AM • Comfort-Aire... • Answered on Apr 21, 2010
0helpful
1answer

Not collecting water but still running

Hi,
Here is a tip that I wrote that will help you...

http://www.fixya.com/support/r3877515-dehumidifier_problems_dehumidifier

heatman101
4/16/2010 3:51:06 AM • Comfort-Aire... • Answered on Apr 16, 2010
0helpful
1answer

Not accumulating water and condensation on top

Your unit is low on freon from a sealed system leak. The sealed system should have a 5 year warranty. You need an authorized LG tech to write it up for an exchange. Check your manual and call an LG service dealer.
1/23/2010 5:20:58 AM • Comfort-Aire... • Answered on Jan 23, 2010
0helpful
1answer

Comfort aire overtemperature switch part no.

Call Heat Controller in Tennesse they distribute this although it is made by LG
1/22/2010 3:30:45 AM • Comfort-Aire... • Answered on Jan 22, 2010
0helpful
1answer

01 error code

check sw. on dehumidifier possibly stuck open
1/16/2010 3:05:17 AM • Comfort-Aire... • Answered on Jan 16, 2010
0helpful
1answer

Fan quitting on unit

Maybe the room is dry enough so the humidity sensor is turning it off?

If not, maybe the thermisensor(fuse) on the fan motor is failing?
1/5/2010 11:00:54 PM • Comfort-Aire... • Answered on Jan 05, 2010
0helpful
1answer

The unit has started sweating cold water droplets

Several possible problems. Filter clean? As strange as this may sound you may have lost a little refrigerant. If problem persists after filter is cleaned, then a Tech needs to look at it.
7/9/2009 8:50:51 PM • Comfort-Aire... • Answered on Jul 09, 2009
0helpful
1answer

Fan and compressor run but coils do not get cold.

your missing some gaz
6/24/2009 9:01:22 PM • Comfort-Aire... • Answered on Jun 24, 2009
0helpful
1answer

Iced up coils and will not dehumidify

I did a little digging around on the internet and found out that if the basement (or where ever you have your unit) is in an area where the room temp might dip below 65 degrees the coils may start to become "too efficient" in pulling the moisture/humidity out of the air and it begins to freeze on the coils before it can drip off into the reservoir. The site said to turn off the unit and let it thaw out, then restart it and see if everything works ok after that. If the temperature gets too low you might need to warm up the air in the room/basement before it will operate correctly again/not continue to freeze up. Hope this helps. Mine just did the same thing but we've had some pretty cold weather recently and the basement is fairly cold as well.
9/28/2008 7:33:32 PM • Comfort-Aire... • Answered on Sep 28, 2008
0helpful
1answer

Tank full light flashes & unit will not operate, but is attached to a hose

If you get a fault code CH 01, check the posting for that solution and see if it helps.
9/22/2008 3:49:09 AM • Comfort-Aire... • Answered on Sep 22, 2008
0helpful
1answer

Water leaks around the bucket even the bucket is in place-bucket collects a little bit of water

It sounds like you need to check the drain under the cooling section. It can fill with dust, lint, cat hair, spiders, etc. and prevent water from draining into the bucket. First, unplug the unit. Don't do anything with AC power present. Then, remove the 2 screws under the front panel where the air filter slides up in and pull off the control panel. There are "snap" latches in the plastic near the top that can be (are) hard to undo, so be careful. You might want to have work gloves on because of sharp edges. Prying with a screw driver will cause permanent dents in the plastic. Also, there is a small, sleeved bunch of wires that goes up the left side to the operator buttons and display. Be careful not to damage it and the circuit board it goes to. Set the front panel aside, wire attached. There is no need to disassemble any of that. The drain is a small 3/8" hole in the black plastic floor of the cooling area at the front, right side. It seems to have a fitting for a hose that feeds through to the back of the unit. Clean any foreign material from it and everything else. Test it, with the bucket in place, by pouring some water in, if you want to. Then clean the dust off of everything so it looks new. Don't get the circuit board wet. Re-assemble, being careful with the front panel wire so it is not pinched and does not prevent easy removal/installation of the filter, and it should be OK.
9/22/2008 3:33:24 AM • Comfort-Aire... • Answered on Sep 22, 2008
0helpful
1answer

Fault Codes

This is more of a tip since I have not actually fixed anything yet. As a test, remove the upper front cover where the buttons and displays are. (2 screws on the bottom then pull off a the plastic snaps) Inside the case on the far left, there is a piece of crimped copper tubing, open on the top end, welded to the refrigerant line, with a black sleeve covering 2 wires out the bottom end. This is a thermistor. I CAREFULLY applied heat with a butane lighter (the mini torch kind, not the "candle flame" kind), taking care not to burn anything. I applied ONLY enough to make it slightly warm to the touch. Do not think of melting anything, as this is not the purpose. Applying too much heat could damage the thermistor. With the bucket in place, the unit started right up. After I did this, it failed again in a few minutes, so I heated it again, and thus verifying it as the source. I have done it a third time, never getting it much over room temperature, and it is still running after almost an hour after doing nothing else. Since this temperature sensing is an analog function to the microcontroller that runs everything, the fault could be any bad connection or solder joint along the way from this thermister to the controller. But is sure appears something in thermistor. I hope my description is complete and clear. Good luck.
9/22/2008 2:23:50 AM • Comfort-Aire... • Answered on Sep 22, 2008
0helpful
1answer

Motor

Your problem may be the thermistor that causes the CH01 trouble code.
9/20/2008 1:36:51 PM • Comfort-Aire... • Answered on Sep 20, 2008
0helpful
1answer

Bucket full

Allergy Buyers Club gave me a replacement item.
5/28/2008 5:39:23 PM • Comfort-Aire... • Answered on May 28, 2008
0helpful
1answer

I'm looking for a float shutoff for Comfort-Aire BHD-651 Dehumidifier.

https://www.amazon.com/HEAT-CONTROLLER-Comfort-Aire-Pint-Dehumidifier/dp/B000RE6X28
4/13/2020 5:30:11 PM • Comfort-Aire... • Answered on Apr 13, 2020
Not finding what you are looking for?
Comfort-Aire BHD-501 Dehumidifier Logo

69 questions posted

Ask a Question

Usually answered in minutes!

Top Comfort-Aire Dehumidifiers Experts

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Brad Brown

Level 3 Expert

19187 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66957 Answers

Are you a Comfort-Aire Dehumidifier Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

View Most Popular

Comfort-Aire Dehumidifiers

  • Comfort-Aire Dehumidifiers

Most Popular Question

disassemble clean

  • Dehumidifiers
Loading...