Konica 7165 error sc 80-02
- Communication error between OACB/PRCB.
- Causes:Printer control board (PRCB) Overall control board (OACB) Loose connection
Konica 7255 error code C23-04
PCL connectionabnormalityE23-04(Di5510/It is checked that the movement of the blade motor (M14) is not completed, and the 24V power source is also checked. The drum READY1 signal (READY condition) cannot be detected within a specified period of time after the drum motor (M2) turns ON. Or, the drum READY1 signal (READY release condition) cannot be detected within a specified period of time after M2 turns OFF. At this time, an error detection signal (24V cut out) is detected.Causes:Drum motor (M2) Blade motor (M14) Printer control board (PRCB) Blade sensor /1 (PS30) Blade sensor /2 (PS31) DC power supply /2 (DCPS2) Wiring harness broken Loose connectionDi7210)Failure of PCL connection is detected.
Konica-7222
the sensor did not sense paper passing through fusing unit.
check sensor by the side door, paper exit unit or paper passage
clean sensor, change if broken
check sensor spring