Maytag MZD2766GES Side by Side Refrigerator Questions & Answers
Mzd2766geb maytag ref freezer door insulation frozen solid with ice
Even if the unit if issue free, this older design is still suseptable to moisture intrusion behind the inner liner. If your ice is below or around where the fointain area is, than you may be leaking water from the fountain behind the outer door shell. Since your outer door and inner liner are no longer avail, the best suggestion is to turn the entire fridge off, and let everything completely dry before re assembly. Once insulation gets imbedded with moisture and freezes, the insulation factor diminishes. Although your outer door insulation should be the newer style semi solid foamed in style, so moisture intrusion will not be any deeper than an inch or so. If the fountain heater has failed around the dispenser, you attract moisture to that area too. Pleazer Appliance...
1/6/2015 1:09:38 PM •
Maytag...
•
139 views • 0 helpful votes
Install water line
It should be marked. And you should have a water line kit with it.
11/7/2014 12:17:03 AM •
Maytag...
•
90 views • 0 helpful votes
Maytag fridge side by side freezer door leaks water
If the insulation in the door has blown, it cannot be replaced. If there is a dispenser in the door, look at all the plastic parts for any splits or leaks. To test if it is the dispenser, turn off the water supply for a few days. If the water stops collecting in the door it's a good sign.
4/22/2014 5:18:59 PM •
Maytag...
•
264 views • 0 helpful votes
Not freezing or cooling and compressor clicking on and off
From your description it sounds like the start components (start relay, overload and capacitor) are having problems. The clicking you hear is probably the overload kicking out to protect the compressor. It is quite possible that the compressor simply has gotten too hot and after sitting a while will restart when plugged back in. The start components are not generally considered 'user serviceable' parts. When the compressor has cooled to pretty much room temp, plug it in and be listening for those clicks. If you hear them, unplug it because it could eventually damage the compressor. Those components give the compressor an extra jolt to get the compressor running then they drop out of the circuit. If the compressor doesn't start, it creates heat until the overload drops out.
3/29/2014 11:24:34 PM •
Maytag...
•
269 views • 3 helpful votes
MZD2766GES compressor not firing
Is your compressor giving sounds like a buzz followed by a click periodically? Is the compressor exterior warm/hot? Most likely the compressor start relay assembly is bad, or the compressor is locked up, (frozen internally). If you connect an amp probe to the red wire of the compressor, and the momentary reading meets or exceeds the LRA rating on the compressor tag, most likely the compressor is at fault. Pleazer Appliance...
4/9/2014 1:05:47 AM •
Maytag...
•
116 views • 0 helpful votes
No ice or water on door
On top of the fridge are plastic covers over the door hinges. The side with ice/water dispenser should have a wiring harness underneath the plastic cover with a wiring harness connector. It may be loose from opening and closing the door causing a poor electrical connection. Try unplugging and reconnect.
10/18/2013 7:05:49 PM •
Maytag...
•
50 views • 0 helpful votes