Top 20 Lakewood (5500) Oil Filled Radiator Heater Questions & Answers

0helpful
1answer

Tip over,now wont restart

Tip-over switch is stuck. Give it a couple love taps.
1/5/2014 2:01:00 AM • Lakewood (5500)... • 192 views • 0 helpful votes
1helpful
1answer

I have a Lakewood convection air heater model

Well, they don't seem to sell parts for these. So the best bet would be to try ebay or craigs list, for a used heater for parts.
3/24/2011 2:11:12 AM • Lakewood (5500)... • 274 views • 1 helpful votes
0helpful
1answer

Need a new switch. Where can I find a model

inside should be a sticker or on the door or on bottom.
3/21/2011 8:01:58 PM • Lakewood (5500)... • 113 views • 0 helpful votes
0helpful
1answer

My Lakewood 5500 purchased Oct

Sorry to be the bearer of bad news, but the lights being on confirms that you have power to the unit, and the lack of heat indicates that the heating element is burned out. No real repair options for these heaters -- it's time to shop for a new one . . .
1/31/2011 2:35:16 PM • Lakewood (5500)... • 180 views • 0 helpful votes
0helpful
1answer

Where does the oil goes

Hi,

Here is a tip that I wrote that will help you to understand about oil filled radiator heaters....

Oil Filled Radiator Heater Leaking
heatman101
1/12/2011 2:46:01 AM • Lakewood (5500)... • 251 views • 0 helpful votes
2helpful
1answer

If this heater layed on its side how long does it

Just 15 minutes is ok.
11/6/2010 1:59:48 AM • Lakewood (5500)... • 1,541 views • 2 helpful votes
2helpful
1answer

How can I find our what the controls mean, the

thegreyone_0.jpg I could not easily find an instruction sheet, but I believe that the top knob is the thermostat... rotate it clockwise for higher temperatures and counter-clockwise to lower the temperature. The lower knob controls the number of heating elements. The first dot/dash if for the 600W element only, the second longer dot/dash is for the 900W element only; and the longest dot/dash is to select both the heating elements giving 1500W total output power.
I hope this helps...
/denis
12/10/2010 6:49:14 AM • Lakewood (5500)... • 427 views • 2 helpful votes
0helpful
1answer

The oil has leaked out of the heater can it be

The heater should not be used -- not economical to repair and not safe to operate.

Charlie
1/9/2011 5:14:39 AM • Lakewood (5500)... • 168 views • 0 helpful votes
0helpful
1answer

No calienta que puede ser estaba calentando bien y

Hola, si tienes problema con argo de liquido salindo del HEATER, por favor combia lo por otro. Si se apprende pero no calienta, entinde que tarda varios minutos en calentar. Si todavia tienes problemas por favor cambia el enchufe al otro en la casa.
Si todavia tienes problemas, escribeme.
GRACIAS
1/9/2011 5:33:24 AM • Lakewood (5500)... • 124 views • 0 helpful votes
0helpful
1answer

When plugged in the light does not come on and it

Check fuse in plug, turn heat setting or thermostat on heater to max.
11/26/2010 11:03:51 PM • Lakewood (5500)... • 245 views • 0 helpful votes
0helpful
1answer

Light doesn't turn on, nor

sounds like it faulted and burned out some wiring i wouldn't use i would get it looked at to make sure all ok as it may now be elecrically dangerous, if that burning smell, smelt like rubber i'd say definatly electrical but without seening it to hard to say
11/20/2010 12:06:20 AM • Lakewood (5500)... • 114 views • 0 helpful votes
0helpful
1answer

Do you ever have to

Hi,
Those units are sealed, this traps the oil inside and provides a maintenance free heating system.
There is no need to and therefore no provision made to add oil to the heater.

heatman101
11/5/2010 12:08:55 PM • Lakewood (5500)... • 145 views • 0 helpful votes
4helpful
1answer

My lakewood oil filled heater model 5600/7 just

The reason that it stopped is an open circuit. It is probably a blown thermal fuse. However, it could be any of the following if that is not the problem:

bad switch, broken or disconnected wire, burned open heater element, bad connections between terminals and wires, or between wire connectors and the wires within them.

If you take it apart, you will find the heat sensitive thermal fuse device under the heating elements, near the bottom of the unit. If the thermal fuse is good, it will appear as a short to an ohmmeter (zero ohms). If it is failed, it will appear as an open (infinite ohms).

The thermal fuse device can be replaced. Here is where to get one:
http://www.goodmans.net/get_list_632_2.htm

The thermal fuse may be this one, but check the temperature indication on yours first: Item#: TH-TF167C

Good luck.
4/6/2010 1:54:22 AM • Lakewood (5500)... • 1,833 views • 4 helpful votes
6helpful
2answers

Need a thermal cutoff for our Lakewood 5500

We have these heaters and haven't had a fuse fail yet. I think it's because after the first time I got that crackling sound after moving it while it was on, I stopped doing that, and only move it with the power off, and wait two minutes before restarting it, so the oil can resettle.

However, the thermostats are now failing. Anyone know if this part is available?
4/10/2010 3:31:47 PM • Lakewood (5500)... • 1,069 views • 6 helpful votes
7helpful
2answers

The Lakewood 5500 oil-filled heater has stopped

Similar problem here. But in my case, it was a blown fuse. There's an in-line fuse on the internal wiring of the heater. Take the control-side off (remove the bottom grey plastic bracket, then remove a sheet metal screw, then slide the whole assembly down off of the radiator). Where the elements go into the reservoir at the bottom of the radiator, the white wire should have an inline fuse connected to it. It will probably be covered with what looks like heat-shrink tubing. Snip, snip, and replace.

1/8/2010 11:28:54 PM • Lakewood (5500)... • 2,085 views • 7 helpful votes
0helpful
1answer

I have 2 Lakewood 5500 oilfilled radiator heaters.

Hi ladybug75846,
I have the same problem. My husband checked the continuity and found out the thermistor is the problem. The thermistor is stamped S.W.C. SW-122. If you find a source for these, would you kindly post it. Thanks!
2/26/2010 10:57:24 PM • Lakewood (5500)... • 306 views • 0 helpful votes
0helpful
1answer

It dosen't turn on when pluged in. This was given

I seriously doubt that you have an oil leak problem. More than likely it blew a fuse or has a break in the power wire. Most oil filled heaters have a thermostat, indicator light and that is about it. There is a long shot it could be the thermostat but I doubt it. Look at the unit and see if it has a fuse holder anywhere. Most likely by the thermostat. It could also be by or in the control panel. This will be a process of elimination. I suppose since it was given to you it could have the heating element burned out in which case you may as well get another unit. Look for the fuse and get back to me.

hardrocko

Thanks for using FixYa
2/13/2010 9:03:43 PM • Lakewood (5500)... • 192 views • 0 helpful votes
1helpful
1answer

If i turn the switches on they light up but

very little sound and it does take quite a while to heat up .. you should feel warmth in 15 min .. if it doesnt heat at all then there might be an open "over temperature" fuse inside ... one of the good things about this heater is that its so quiet ..
11/23/2009 6:56:13 AM • Lakewood (5500)... • 395 views • 1 helpful votes
Not finding what you are looking for?
Lakewood (5500) Oil Filled Radiator Heater Logo

Popular Tags

65 questions posted

Ask a Question

Usually answered in minutes!

Top Lakewood Heating & Cooling Experts

Ronny Bennett Sr.
Ronny Bennett Sr.

Level 3 Expert

6988 Answers

Paul Carew

Level 3 Expert

3808 Answers

Jay Finke
Jay Finke

Level 3 Expert

1397 Answers

Are you a Lakewood Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

View Most Popular

Lakewood Heating & Cooling

  • Lakewood Heating & Cooling

Most Popular Question

lakewood convection air heater model

  • Heating & Cooling
Loading...