1answer

Y a t'il un niveau d'huile dans la comet bxd 2525

L'utiliser cette pompe sans huile est une erreur fatale:

[PDF]COMET PLUNGER PUMP SERVICE MANUAL INDEX

www.cometpump.com/_images/support/Pump_Repair_Manual.pdfLUBRICATION: Make sure crankcase is filled with Comet Pump oil. Running this pump without oil will cause damage and void any warranties. Change the pump ..
8/3/2015 1:51:29 AM • Comet BXD 2525 G... • Answered on Aug 03, 2015 • 322 views
0helpful
1answer

Oil seeping from Comet BXD 2525 pump

out the drain plug ? Sight glass window ? Under the pump where the crankcase meets the pump head? tighten plug, replace oring on sight glass or replace low pressure seals if near the pump
12/16/2014 2:34:23 AM • Comet BXD 2525 G... • Answered on Dec 16, 2014 • 516 views
0helpful
1answer

I have COMET CAWD1069 front loading washing machine with EC6 error code?

The washing machine doesn't exist https://www.google.com/search?q=COMET+CAWD1069 And the EC6 Error is only mentioned here for Frigidaire. https://www.appliancevideo.com/repair-help/question/ec6-error E6 is the common error in washing machines in Whirlpool, LG and Defy. https://www.google.com/search?q=washing+machine+E6+Error ...
9/29/2023 7:30:37 PM • Comet Garden • Answered on Sep 29, 2023 • 59 views
0helpful
1answer

Can I clean my bath tub with muriatic acid

You can utilize the grating idea of muriatic Acid - a typical mineral acid - to free your bath of rust stains. Muriatic acid is accessible from your nearby home improvement shop and should be dealt with cautiously as it is quite caustic.
2/20/2020 3:48:36 PM • Comet Garden • Answered on Feb 20, 2020 • 196 views
0helpful
1answer

What is the nominal consumption in amps of the comet ka 2500's motor

2.9 kw/h up to 4.5 kw/h depending on the model.
8/3/2015 1:23:23 AM • Comet Garden • Answered on Aug 03, 2015 • 132 views
0helpful
1answer
0helpful
1answer

Little plastic parts behind the six big nuts on brass end of the pump have melted.

Hi These are the valves If they are melted this is because the washer is being left running without being triggered. I also suspect yoru unloader may be failing...your will want your unloader tested. The only way to test anything is to replace these valves first. unfortunately I would also inspect your packings as well as the pistons. when water builds up for a length of time without triggering the washer it recycles and builds up heat....this heat starts to melt your valves....this can also happen by starving your pump for water....running it without water....or by a failed unloader where it doesnt allow water to bypass...do you have to pull the trigger of your wand to start it? If so then your unloader needs work. If it has been starved for water..then your packings will show that damage as well...Usually the farthest set from the inlet having the most damage. Also, when that all get hot as soon as you trigger it and cold water is introduced into the pump, this "shocks" the pump packings and pistons. You want to check the pistons to see if they have cracked..So inspect your pump oil for water...look to see if its white-ish looking... Check your pistons for cracks...check your packings for wear. If you see wear that increasingly gets worse the farther away from your pump inlet then thats a tell tale sign of starvation. ..if your pistons are cracked you will need to replace packings as well anyway. Then replace your valves...reassemble and test your unloader. Good luck to you man. You can get all parts here Pressure washer parts catalog quick links Pressure Washers High Pressure... or FIND PARTS FAST
2/26/2015 9:46:28 PM • Comet Garden • Answered on Feb 26, 2015 • 183 views
0helpful
1answer

What is a comet

Comet is a company that makes high pressure washer pumps. Usually sold by northern tool
2/23/2015 12:02:35 AM • Comet Garden • Answered on Feb 23, 2015 • 178 views
0helpful
1answer

ZWD 4030 manual needed

service manual https://www.pwmall.com/PDF/CometServiceManual.pdf
12/16/2014 3:08:45 AM • Comet Garden • Answered on Dec 16, 2014 • 297 views
0helpful
1answer

Comet axd 3020 will not build pressure

junk axial wobble plate pump. Usually axial pumps are not worth the time to try to fix them. This one has a 5 year warranty , so they think they have a pretty good one. ( I would never buy one) If you want to try to fix it, I would check the check valves first. Take them out and see if some are broken or not sealing properly. There is a valve kit available. The other likely problem is your unloader valve. If the seal is shot or the valve stuck open the pump will not build pressure. parts diagram http://www.ppe-pressure-washer-parts.com/files/1961581/uploaded/axd-PUMP%20BREAKDOWN.pdf
12/16/2014 2:59:12 AM • Comet Garden • Answered on Dec 16, 2014 • 743 views
0helpful
1answer

Where does the detergent siphon hose connect on

From the hydraulic pump. there should be a little nub to place the hose on
8/9/2013 7:54:28 AM • Comet Garden • Answered on Aug 09, 2013 • 190 views
0helpful
1answer

Looks like fuel isn't getting to the carburator

If you are using gasoline that has alcohol in it for air pollution control, it may have ruined the seals in the carb.
5/20/2013 4:17:47 PM • Comet Garden • Answered on May 20, 2013 • 50 views
0helpful
1answer

AXD2325 Comet pump Low pressure

Hi, Clean out inlet filter(s). There maybe more than 1 filter to clean out. Good luck.
6/12/2011 11:11:42 PM • Comet Garden • Answered on Jun 12, 2011 • 482 views
0helpful
1answer

When i start the machine

Check your air filter, its probably clogged. remove it and start. if it continues to run, the filter needs to be replaced.
1/29/2011 7:48:46 AM • Comet Garden • Answered on Jan 29, 2011 • 81 views
0helpful
1answer

Water flowing from weep hole continuously,and

With out a diagram i cannot say for sure but i kinda doubt that it has to do with your by-pass.
10/19/2009 12:37:13 AM • Comet Garden • Answered on Oct 19, 2009 • 251 views
0helpful
1answer

Cannot start my Comet pressure washer...water runs

Hi: Some things to check: Is the gas old or contaminated with water. Change it if you are unsure. Are you getting a spark? To check this: BE CAREFUL. Remove the plug. Plug it back into its wire. Hold it WITH INSULATED PLIERS so the tip is close to the metal frame of the machine and have someone pull the starter cord. The plug should spark.
6/27/2009 7:33:33 PM • Comet Garden • Answered on Jun 27, 2009 • 150 views
0helpful
1answer

I have a Comet BXD

the water inlet needs a gasket like all hose connections. If its gone the pump may be starving for water.
4/25/2009 10:13:45 PM • Comet Garden • Answered on Apr 25, 2009 • 1,472 views
0helpful
1answer

Power washer problem no pump action

sounds like nozzle is blocked.small bits of grit jam nozzle unscrew and make sure its clear turn water on and pull trigger to see if gun trigger works,then refit nozzle check again for spray.if clear start up and try out.if no go then pump probably needs cleaning and relubing seals.
4/21/2009 10:45:29 AM • Comet Garden • Answered on Apr 21, 2009 • 577 views
0helpful
1answer

What are some broadleaf evergreen weeping trees?

TreeKisan is a AI- based Platform where tree farmers can know the standing tree market valuation in just 1 minute and sell to potential buyers. Easily assess the economic potential of your trees and make informed decisions. Download TreeKisan Now!
4/17/2024 9:39:10 AM • Garden • Answered Yesterday • 63 views
Not finding what you are looking for?
Comet BXD 2525 G Pressure Washer Pump Logo

5 questions posted

Ask a Question

Usually answered in minutes!

Top Comet Garden Experts

Brad Brown

Level 3 Expert

19187 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66830 Answers

Steve Pack
Steve Pack

Level 3 Expert

7121 Answers

Are you a Comet Garden Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...