Coleman MSR-C Oil furnace were does that white and blue wire go after they come from the fan blower thanks
Guessing. Combustion blower motors often have power to the motor wires or leads , and a pair of signal wires or leads as a sensor for motor operation. This sensor feature is so the burner is not activated if the combustion blower motor does not work
The sensor integrated in the motor may be a centrifugal switch or a hall switch / sensor that connects to the combustion control board as a safety.
Replace the motor, along with the sensor, if either motor or sensor fails.
Combustion switch error on windy days
The switch is not the problem ,it is doing it job.
Locate your vent and put a bend over it because what is happening is on windy days wind will get into vent blowing that combustion air back to furnace causing pressure switch to tripped.
Exterior CKL49-1A AC Unit not blowing cold air
Why you need to change evaporator coil when condenser fan not working ,also why would you even charge unit with looking for leak.
Maybe the evaporator coil is leaking and when you recharge it it work for couple of days now unit is empty again .
If unit have low pressure switch then outside unit would shut off.