Coleman powermate 3250 - Answered Questions & Fixed issues

0helpful
2answers

I checked all the links and can’t find the owners manual for my Coleman Powermate PM0543250. Particularly where is the dipstick for checking the oil?

it doesnt have a dipstick and its that yellow cap. you fill oil to the edge of that after you remove the cap.
2/12/2021 11:39:23 PM • Coleman... • Answered on Feb 12, 2021 • 203 views
0helpful
1answer

How do i remove oil sending unit from a 3250? when i unscrew it ,it seems to be connected inside the engine..

the fitting on the side is for the wires the sensor is bolted inside the engine block
9/4/2012 1:37:23 AM • Coleman... • Answered on Sep 04, 2012 • 225 views
0helpful
1answer

Will not start

Make sure you have fuel, spark and compression.
4/22/2012 10:13:10 PM • Coleman... • Answered on Apr 22, 2012 • 137 views
0helpful
1answer

How much wattage does my Coleman Electric central heating furnace with integral limit control 3120-751 use?

The wattage of a furnace can vary based on the model and its specific features. I couldn't access a manual with this information. Perhaps customer support or a dealer can assist with the informaiton. Contact Us ' Support: Get In Touch With Us ' Coleman® Find a Dealer ' HVAC Systems ' Coleman® (colemanac.com) Have the model number handy.
4/19/2024 5:38:48 AM • Coleman... • Answered 17 hours ago • 201 views
0helpful
1answer

I have an 1850 Coleman powermate that spews gas from gas cap vent, replaced with new one and still does it. How do I fix?

Troubleshoot this problem: Check Fuel Level: Ensure that the fuel level is not too high. If the tank is filled to the brim, it might cause excess pressure and lead to fuel spewing from the vent. Gas Cap Design: Some gas caps have a metal cone inside to deflect fuel away from the vent hole. Make sure you have the correct gas cap for your generator. The vent hole may not go through the top of the cap but vents under the gasket inside it. Vapor Lock: Coleman customer support suggests that vapor lock could be a possible cause. Try the following steps: Clean the carburetor and its bowl. Disconnect the gas line to ensure it's clear. Use fresh fuel. Inspect the Gas Cap: Double-check that the new gas cap you installed matches the correct part number according to the parts list. Replace the Gas Cap: If all else fails, consider getting a replacement gas cap specifically designed for your Powermate 1850 generator. You can find suitable gas caps online or at authorized dealers. PowerMate Formerly Coleman Gas Caps 4-Cycle - Jacks Small Engines
4/19/2024 5:18:05 AM • Coleman... • Answered 17 hours ago • 13 views
0helpful
1answer

PM0621512 15000W Coleman Generator not starting

An OVERCRANK fault implies no start after three attempts. Most likely a fuel issue.
11/25/2023 1:26:24 PM • Coleman... • Answered on Nov 25, 2023 • 48 views
0helpful
1answer

I am looking for an owners manual for a Coleman gasoline powered 120/220 generator

Coleman is now Powermate.

https://www.powermate.com/generators/portable-generators

Post model number and likely someone will comment with a URL address of the manual.
11/2/2023 10:40:38 PM • Coleman... • Answered on Nov 02, 2023 • 38 views
0helpful
1answer

I have a Coleman Power Mate PM400911 Home Standby Generator. .

9/6/2023 8:23:14 AM • Coleman... • Answered on Sep 06, 2023 • 32 views
0helpful
1answer

Coleman Vertex 5500 Generator. Where is the starter solenoid on it please.

Question edited for clarity and spelling errors. Follow the heavy gauge positive wire from the battery. It is shown in the link. https://www.google.com/search?q=Coleman+Vertex+5500+Generator.+Where+is+the+starter+solenoid and https://www.google.com/search?q=coleman+vertex+5500+generator.+starter+solenoid+replacement ..
7/29/2023 5:46:15 PM • Coleman... • Answered on Jul 29, 2023 • 39 views
0helpful
1answer

What is/would be the price for a replacement motor for a coleman powermate aircompresser

Not sure which unit you have as they make several. But here's some sites to check out.. https://www.google.com/search?q=coleman+powermate+air+compressor+motor
7/28/2023 6:45:22 PM • Coleman... • Answered on Jul 28, 2023 • 39 views
0helpful
2answers

How to remove a rusty fuel tank for cleaning

When dealing with specific equipment like the Coleman Powermate Pro 6750 generator, it's important to follow proper procedures and consult the manual for disassembly instructions. However, I can provide some general guidance:
  1. Look for hidden screws or fasteners: Check for any additional screws or fasteners that may be securing the plastic control panel to the generator frame or the fuel tank. These may not be immediately visible or obvious.
  2. Disconnect electrical connections: Before attempting to remove the control panel, make sure to disconnect any electrical connections that may be attached to it. These could include wires or connectors for the generator's controls, switches, or displays.
  3. Release clips or tabs: Some control panels may have clips or tabs that hold them in place. Look for any release mechanisms that may need to be pressed or disengaged to remove the panel.
  4. Seek guidance from the manufacturer: If you don't have the manual or are unsure about the disassembly process, it's recommended to contact Coleman Powermate customer support or visit their website. They can provide you with the specific instructions or guide you through the steps needed to remove the control panel and access the fuel tank.
Remember to exercise caution and prioritize your safety when working with equipment like generators. If you are uncomfortable or uncertain about the process, it's best to seek professional assistance or consult a qualified technician to avoid any potential damage or harm.
6/18/2023 5:01:58 PM • Coleman... • Answered on Jun 18, 2023 • 45 views
0helpful
1answer

Manual for Coleman Powermate Pro 6750 Generator model PM0606750

google coleman powermate pro 6750 manual copy and paste link https://manualsbrain.com/en/manuals/1408153/
6/17/2023 4:24:58 PM • Coleman... • Answered on Jun 17, 2023 • 57 views
0helpful
1answer

Coleman pm1500 started it up plugged in extension cord to much load killed motor now getting no fire from engine

It sounds like your Coleman PM1500 generator may have experienced a serious issue due to overloading, which may have caused damage to the engine or electrical system. To troubleshoot the issue and restore power to the engine, you may want to try the following steps:
  1. Check the oil level and fuel level: Make sure that the oil level in the engine is sufficient and that the fuel tank is not empty.
  2. Check for any visible signs of damage: Check the generator's components, including the engine, spark plug, and electrical system, for any visible signs of damage or wear.
  3. Test the spark plug: Remove the spark plug and inspect it for damage or fouling. If it appears to be damaged or fouled, replace it with a new one.
  4. Check the electrical system: Use a multimeter to check the voltage output of the generator's electrical system. If the voltage is low or non-existent, there may be an issue with the generator's alternator or voltage regulator.
If you are unable to diagnose and fix the issue yourself, it may be best to take the generator to a qualified repair technician who can help you identify and address the problem.
3/19/2023 3:14:05 PM • Coleman... • Answered on Mar 19, 2023 • 42 views
0helpful
1answer

Coleman Powermate starts but dies after 10 seconds

It sounds like you've already done a lot of troubleshooting, but here are a few more things to check:
  1. Spark Plug: Check the spark plug for any visible damage or deposits, replace if needed. Make sure it is tightened properly and there is a strong spark when cranking the engine.
  2. Fuel Filter: Check the fuel filter for any clogs or debris, replace if needed.
  3. Air Filter: Check the air filter for any damage or clogs, replace if needed. A dirty air filter can restrict air flow to the engine and cause it to stall.
  4. Vacuum Leaks: Check for any vacuum leaks in the fuel system, this can cause the engine to run poorly and stall.
  5. Governor System: The governor system regulates the speed of the engine. If it's not functioning properly, the engine may stall. Check the governor arm, linkages, and springs for any damage or looseness.
  6. Ignition System: Check the ignition system, including the ignition coil and ignition module, for any signs of damage or wear. Replace if necessary.
  7. Fuel Pump: Check the fuel pump for proper operation, the fuel pump may be failing and not delivering enough fuel to the engine.
These are just a few possibilities, and it's best to consult the owner's manual or a professional mechanic to diagnose and repair the issue.
2/13/2023 5:53:52 AM • Coleman... • Answered on Feb 13, 2023 • 68 views
0helpful
1answer

I need an owners electrical manual for a 2012 coleman 30' 5th wheel

notify colman ---or an rv shop/dealer --
2/10/2023 3:44:36 PM • Coleman... • Answered on Feb 10, 2023 • 25 views
0helpful
2answers

Trying to wire in the outlets on my generator

power mate 8000 series.no model told or serialmoved this to generatorsask maker for help, or seller the GEN is country specific, none told.moved this post generators..
3/19/2023 3:11:02 PM • Coleman... • Answered on Mar 19, 2023 • 248 views
0helpful
1answer

I have a coleman powermate 5500 series generator powered by a yamaha mz 300 need whole wiring diagram

talk to a specialist at this linkhttps://www.justanswer.com/
1/18/2023 8:02:00 PM • Coleman... • Answered on Jan 18, 2023 • 31 views
Not finding what you are looking for?
Electrical Supplies Logo

16 questions posted

Ask a Question

Usually answered in minutes!

Top Coleman Electrical Supplies Experts

Jay Finke
Jay Finke

Level 3 Expert

1397 Answers

Sean Wright
Sean Wright

Level 3 Expert

2045 Answers

john h

Level 3 Expert

29494 Answers

Are you a Coleman Electrical Supply Expert? Answer questions, earn points and help others