Drawing

how much amps the pump motor is drawing at start up and then while running
9/7/2014 4:25:24 AM • Pentair 1 hp... • Answered on Sep 07, 2014 • 64 views
0helpful
1answer

Removing impeller from OJ800 water pump

The impeller has a reverse thread locking screw through the center. You can secure the motor shaft by putting a 9/16 open end wrench on the other end of the shaft, which is under a cap in the middle of the rear of the motor. Check your seal plate carefully. Whisperflo is a great pump but they don't take heat very well. It is very common for the seal plate to also be damaged when the pump runs hot, particularly the lower inserts where the bolts screw into.
1/9/2014 8:05:56 AM • Pentair 1 hp... • Answered on Jan 09, 2014 • 146 views
0helpful
1answer

Whisperflow pump making loud squealing noise

The noise is likely either the seal or a bearing in that order. If you are mechanically capable of working on the pump yourself then you can purchase a seal and gaskets at a pool supply store. If the bearings are bad then the motor needs to be replaced. In some cases a bearing can be replaced but usually it is more work than it is worth.
8/9/2011 9:58:02 PM • Pentair 1 hp... • Answered on Aug 09, 2011 • 451 views
0helpful
1answer

How to strip pool pump, pantera bearing has pack

You are probably wondering how to remove the impeller - generally, these are screwed on to tha motor shaft - motors normally run clockwise when viewed from the rear, so thread is normal right hand. remove fan cowl and fan from motor in order to be able to restrain the shaft while you unscrew the impeller - it should be straightforward from there.

Bearing failure is more often than not brought on by leakaege from the mechanical seal - when you reassemble the pump you should replace the seal assembl - also make sure that there is no damage in the form of melted plastic around the seal stationary seat area; replace parts as necessary.
1/24/2011 8:26:41 PM • Pentair 1 hp... • Answered on Jan 24, 2011 • 307 views
0helpful
1answer

I have a whisperflo. I've ran the motor without

Yes the impeller is screwed on right handed normal thread. *** Info below pasted form one of my other posts *** You need to lock the motor and unscrew impeller. Depending on the motor, you remove a cap in the middle of the tail piece and hold with a wrench, (usually 9/16") or remove a cap that covers the whole end and grab the shaft with a wrench (usually 7/16") by sliding it under one of the components (not sure exact part off top of my head have to look at it) and then turning impeller. If the impeller has a bolt or screw in the middle remove that first. (you already did this.) It should be reverse thread so make sure you don't turn the wrong way and break or strip. If there is no screw, or after you've removed it, just spin the impeller off (it should be counter clockwise standard thread). If you can't do it by hand and assuming you don't have an impeller wrench, be very careful and use a large pliers, pipe wrench, or strap wrench to loosen it.
9/28/2010 8:01:00 PM • Pentair 1 hp... • Answered on Sep 28, 2010 • 273 views
0helpful
1answer

How to seperate pump from motor

Disconnect all power. Remove the six bolts holding the seal plate to the wet end. Remove the two small allen screws to remove the diffuser. Remove the dust cap from the end of the motor and secure the shaft from moving. If installed, remove the Phillips head screw in the center of the impeller by turning clockwise (left hand threads). You can now remove the impeller by turning counter clockwise, note that you may need an impeller wrench to remove it and a specific tool to hold the shaft while you remove the impeller. Once the impeller is off you can remove the four bolts that hold the motor to the seal plate. This process just needs to be reversed to re-install but you will need a new shaft seal (PS-1000).
7/4/2010 3:31:15 PM • Pentair 1 hp... • Answered on Jul 04, 2010 • 531 views
0helpful
2answers

My Pentair Easy Touch system will come on randomly.

Sometimes its a simple Power Cycling that's needed. Fancy term for going to the outdoor pool panel, flipping all the breakers to off, counting to 10, then turning them back on again. Hope this helps
3/13/2023 10:43:36 PM • Pentair Pool &... • Answered on Mar 13, 2023 • 88 views
0helpful
1answer

Pentair mastertemp 250 codes Ad0 and 5F1. After my dog ate the conduit & wires which I replaced. Also get the dreaded E05 which I know is the stack temp sensor. Anyone know what the other codes mean?

I found it to be a dirty filter. I wasn't getting the error 5 code just ADO and 5f1
1/10/2023 10:07:41 PM • Pentair Pool &... • Answered on Jan 10, 2023 • 2,505 views
0helpful
1answer

My Pentair Intelliflo control panel is frozen I push buttons and nothing changes on the screen

What does the LCD Screen say? Does it say display not active?
12/29/2022 5:38:01 AM • Pentair Pool &... • Answered on Dec 29, 2022 • 65 views
0helpful
1answer

Pentair master 400 controller will not respond to touch

Do you have an Easy Touch Controller?
12/29/2022 5:33:38 AM • Pentair Pool &... • Answered on Dec 29, 2022 • 50 views
0helpful
2answers

Pentair spa and pool control

Yes, the water must be circulating rapidly when the heater is on from being cold. Once hot, it can just circulate gently.
12/29/2022 5:29:46 AM • Pentair Pool &... • Answered on Dec 29, 2022 • 42 views
0helpful
1answer

Incorrect temperature reading on Pentair Mastertemp 400 pool heater

Sometimes it is best to call in the professionals who have the knowledge and tools to find problems.
11/3/2022 12:57:16 AM • Pentair Pool &... • Answered on Nov 03, 2022 • 113 views
0helpful
1answer

Pentair Mastertemp 250 occasionally gets error E05.

stack flue sensor heater overheated check gas pressure if ok sounds like occasionally low pressure if pressure ok check for burner tubes blocked
9/25/2022 4:59:43 AM • Pentair Pool &... • Answered on Sep 25, 2022 • 207 views
0helpful
1answer

My Pentair Easy touch wireless remote is receiving data from the outdoor panel but i can't turn anything on or off with it. Any suggestions?

Usually resetting the 'Service' breaker on the main control box resolves this. If not, even though your remote receives data, you may still want to replace batteries in the remote. Next would be a faulty remote transceiver board ( cheaper to replace than the next item), in the unit with the antenna, or the mother board (the more expensive item).
8/18/2022 4:48:07 PM • Pentair Pool &... • Answered on Aug 18, 2022 • 572 views
0helpful
1answer
0helpful
2answers

Pentair legend II pool cleaner,

From your description that is bad service Go online and google Pentair legend II pool cleaner hose swivels
8/6/2022 3:59:22 AM • Pentair Pool &... • Answered on Aug 06, 2022 • 81 views
0helpful
1answer

Pentair Mastertemp 250 heater that turns on, but shuts off after about 30 minutes

make sure gas pressure is correct if too low it will overheat or possible blocked burner tubes
8/6/2022 3:57:06 AM • Pentair Pool &... • Answered on Aug 06, 2022 • 267 views
0helpful
1answer

Can you have check valves when you have a intelliflo vs+svrs pump 011017 ?

no country told (down under?) parts and manuals and things vary all over earth. well they did not lie to you, as it would damage the pump.\ but I see you are reading the wrong manual.. learn that systems of many kinds vary by model or submodel or version even not known by you. some even vary by build dates. or from upgrades ask them only or bad things can happen. Pentair Intelliflo Variable Speed Energy Efficient Pump VS+SVRS 3.2kW 3HP Max 230V swimming pool or spa? or what? not told, (all of it) nobody knows what you have there, for sure huge pools., all piping valves etc. why not call for a real service tech>? if down under ask them (Australia)???? not told https://www.pentairpool.com.au/en/185/Home/Products/Pumps/Filtration-Pumps/-/intelliflo-vs-6 this manual contradicts you , per page 2 3:Use a check valve in the discharge line when using this pump for any application where there is significant height (head) to the plumbing after the pump. 4.Be sure to install check valves when plumbing in parallel with another pump. This helps prevent reverse rotation of the impeller and motor.<<< damage. not told the application, wow, gee some pumps are below grade of pool, and is called HEAD, and with any far distance up, the check valve keeps the pool for draining to the pump area during service. (the same true on suction side a pump down to a deep well losing prime. NO APPLICATION TOLD at all no real answers possible blind
7/30/2022 12:55:44 PM • Pentair Pool &... • Answered on Jul 30, 2022 • 60 views
Not finding what you are looking for?
Pentair 1 hp WhisperFlo InGround Pool Pump  WFE24 () Logo

9 questions posted

Ask a Question

Usually answered in minutes!

Top Pentair Pool & Spa Experts

Jay Finke
Jay Finke

Level 3 Expert

1397 Answers

Brad Brown

Level 3 Expert

19187 Answers

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Are you a Pentair Pool and Spa Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...