Top 20 AO Smith 1 hp 3450rpm 56Y Frame 115230 volts Square Flange Energy Efficient Pool Pump Replacement Motor Century (Pentair Whisperflo) Questions & Answers

1helpful
1answer

Want to replace with either a two speed or variable speed motor, and suggestions?

You will need to install a special controller if you change to a 2 speed. Because there will be an additional wire (4 wires vs. 3) with a 2nd speed to operate. If you go with a variable speed motor, then again, a special controller will be required to utilize a reo-stat type of switch with will allow a selection of slowly increasing voltage to motor which will in turn allow the motor to spin quicker. Instead of the hassle above, just go with a "One deal package" all nicely bundled ready for installation. It has it all within it - What...? A variable speed complete pump! That will be the sweetest thing for you if you are looking to go that route! Check these out... Aqua Leisure Relax in Comfort Pool Lounges Good Luck
4/4/2015 2:02:15 PM • AO Smith 1 hp... • 162 views • 1 helpful votes
0helpful
1answer

Wiring line side of 230v two speed pool pump. It has line 1-4 which do I use

There should be a schematic on that motor describing how to connect the power. You would definitely want to use 230 volts as this allows the motor to run more efficiently.

A thumbs up would be greatly appreciated if this answer is helpful to your free Fixya question.
4/12/2014 5:05:33 PM • AO Smith 1 hp... • 130 views • 0 helpful votes
0helpful
3answers

Wiring a single speed 230v 5hp ao smith pump: what

L1 and L2 are the posts to hook up to, there is no polarity so either way works,
10/6/2013 8:12:46 PM • AO Smith 1 hp... • 604 views • 0 helpful votes
0helpful
1answer

Wiring a 230/115 1 hp 56y pool pump motor

please verify the name plate to be 115 230 volt motor.there will be a schematic that shows you exactly how to hook up this motor depending on the voltage being supplied to it. The main thing is switching between 115 and 230 volts this is a selector switch this very easily forgotten about. Please make sure to check that and double check that to make sure its on the proper selected switch. Good luck

A thumbs up would be greatly appreciated if this answer is helpful to your free Fixya question
6/30/2012 12:42:56 AM • AO Smith 1 hp... • 599 views • 0 helpful votes
0helpful
1answer

A.O smith pool pump tripping breaker

It you either have an impeller problem or capacitor problem on the motor. I would take the capacitor off and take it to a electronic or lexical shop to have them check it. It's only about 15 to 20 dollar pics if it's just your capacitor.

A thumbs up would be greatly appreciated if answer is helpful for your question. THANK you and GOD BLESS YOU.
4/8/2012 2:53:16 PM • AO Smith 1 hp... • 481 views • 0 helpful votes
0helpful
1answer

My new AO Smith motor does not have an L1 IT has L2, L3, and L4 so how do I hook the wires?

There is a schematic on the motor itself to show you exactly how to hook it up. The main thing is knowing whether it's 115 volt or 230 volt connection. Good luck any questions hit me back up.

A thumbs up would be greatly appreciated if answer is helpful for your question. THANK you and GOD BLESS
4/26/2012 1:35:26 AM • AO Smith 1 hp... • 196 views • 0 helpful votes
1helpful
1answer

Wiring a 230v ao smith

Hi, assuming you have 4-conductor wire, use the black and red wires for L1 and L2. It doesn't matter which goes to which. If you do not have a red wire, use black and white. The green or bare wire in a 3-wire cable goes to the ground. If you have 4-conductor wire, the ground wire is the one you used for the GFCI on the breaker--usually the white wire. Please let me know if you have more questions, and thanks for using FixYa.
8/8/2011 1:43:23 AM • AO Smith 1 hp... • 1,775 views • 1 helpful votes
0helpful
1answer

Changing from 115 to 230

0

Usually - depends on the type of wire originally installed. Almost all of it is going to be rated 300V or more and if yours is then yes, change the breaker to a 2-pole and swap out any other devices in the circuit to be rated 230 and change the voltage selector on the pump motor to 230 and you are good to go. Examine the markings on your wire insulation to find the voltage ratings.



A thumbs up would be greatly appreciated if this answer is helpful to your free Fixya question
5/10/2011 6:04:29 PM • AO Smith 1 hp... • 181 views • 0 helpful votes
0helpful
2answers

Trying to find part numbers for ao smith model c48a95ao6 shallow well pump motor shaft bearings

notify goulds -----https://www.gouldspumps.com/en-US/Home/ or online search and open one of the 1000's of part sites
4/2/2022 12:55:03 AM • AO Smith Pool &... • 71 views • 0 helpful votes
0helpful
1answer

I need a run and start capacitor part number for AO Smith s number k56a67 b23 serial number 2C 02 type k d 2 3 3 6 0. What is the start and run capacitor part ?

The values are stamped on the old capacitors. If you haven't got them, I would contact the manufacturers authorised agent for advice.
5/23/2021 12:03:35 PM • AO Smith Pool &... • 128 views • 0 helpful votes
0helpful
2answers

My ao smith c48c53a06 jet pump is dead and not tripping the breaker. I verified it has incoming power. Could it be the capacitor? If so what type of capacitor does it use?

remove bump on motor and take picture of wiring before removing get numbers off try electrical supply
9/7/2020 1:17:32 PM • AO Smith Pool &... • 330 views • 0 helpful votes
0helpful
1answer

Ao smith well pump model number C48A95A06: Pump is running, but not pulling water, what could be the cause?

Try priming it water at the filter. Make sure that the filter o ring is sealing under the cap. Make sure there is enough water in the pool to enter the suction line and that it is not restricted.
7/20/2019 2:56:09 PM • AO Smith Pool &... • 931 views • 0 helpful votes
0helpful
1answer

I want to reversenrotstion on my ao smith 3hp single phase 220v motor

Can't do it electrically. See if you can flip the armature and use that in that direction [bit of a long shot here - sorry]
1/19/2018 3:45:51 AM • AO Smith Pool &... • 108 views • 0 helpful votes
1helpful
1answer

AO Smith 1.5 HP pool pump motor. Voltage selector broken. Three wires to the switch,Purple, black and white w black stripe. Which two should be connected for 230 volt operation?

Try the black to L2 (L2 will be your Purple). L1 should be connected direct and separate. The black/white striped wire should get capped off. http://www.inyopools.com/HowToPage/how-to-use-a-multimeter-to-test-a-pool-pump-motor.aspx?CommentPage=1
6/17/2017 6:57:51 PM • AO Smith Pool &... • 410 views • 1 helpful votes
1helpful
2answers

How to covert a 220 motor to a 115vac motor. ao smith rpm3450 3.hp 15 amps

If your label looks like this one and or if your label dose not have 120 as one of the voltages then you can not run the motor on 115 volts. century-sq1302v1-2-yrzb4gnga4otx0okltvk2h2e-3-0.jpg
4/16/2017 8:18:55 PM • AO Smith Pool &... • 94 views • 1 helpful votes
0helpful
1answer

Wiring diagram AO Smith ST1102 pump motor

There is almost always the wiring diagram on the outside of every spa motor. Bath Spa Parts Online
7/24/2016 1:40:34 PM • AO Smith Pool &... • 1,642 views • 0 helpful votes
0helpful
3answers

Hi,i have a AO Smith S# c56a05a19 HP 3/4 ,type C, v 115/230 , Ph 1.0. I need to connect it to 230 volt. , can´t find a Wiring diagram. Can someone please help??

Yes this is an old thread but info is still helpful to those that are searching. Here is one diagram from a 3/4 motor. Be aware that most residential high voltage are 240v. This will have the motor turning a bit faster.

e2e4150d-3d45-409f-8088-71306dddf2fb.jpeg
2/9/2015 8:17:33 PM • AO Smith Pool &... • 1,915 views • 0 helpful votes
0helpful
1answer

I have a 2hp AO Smith motor on a Sears Premium sprinkler pump and the plastic casing has cracked al, the way through. I was wondering where I could find a replacement casing?

Try sears? Or amazon. Depending on the Frame of the AO Smith Motor, you can really put on any kind of Wet End, which is what you called the casing. Just ensure that you get the correct HP
3/4/2015 7:27:47 PM • AO Smith Pool &... • 111 views • 0 helpful votes
Not finding what you are looking for?
AO Smith 1 hp 3450rpm 56Y Frame 115230 volts Square Flange Energy Efficient Pool Pump Replacement Motor   Century  (Pentair  Whisperflo) Logo

8 questions posted

Ask a Question

Usually answered in minutes!

Top AO Smith Pool & Spa Experts

Jay Finke
Jay Finke

Level 3 Expert

1397 Answers

john h

Level 3 Expert

29492 Answers

David Spradling
David Spradling

Level 3 Expert

13520 Answers

Are you an AO Smith Pool and Spa Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

View Most Popular

AO Smith Pool & Spa

  • AO Smith Pool & Spa

Most Popular Question

want replace either two speed or

  • Pool & Spa
Loading...