20 Most Recent
Generac Power Systems Generac 0057890 3250 Watt Gasoline Generator - Page 4 Questions & Answers
Powerhouse 3100RI has no spark, plug has been changed. Where to look and what to check
It has low oil level cut off which will prevent spark. Check there is sufficient oil in the engine crankcase. Oil level alert sensors are a common failure so if there's sufficient oil then disconnect the sensor. If engine then runs, replace oil alert sensor.
Owners manual is available, no fee download, at the following URL.
https://www.manualslib.com/manual/722234/Powerhouse-Ph3100ri.html#manual
How to set the float level in an etq tg1200 generator
Float levels don't just go bad. But that said you pull the carb and turn it upside down and set the float to be level with the bottom of the carb (bottom with the carb upside down.) Most new stuff doesn't have an adjustment. They break fairly easily. Don't ask how I know.As long as you have it apart, pull the float and hold it down in a cup of fairly hot water and see if it bubbles which would indicate a hole in the float which would let too much gas into the carb causing flooding.Make sure you clean the needle valve and seat and the carb inside while you are at it.
Powermate wont start.coil pulls real hard.
Recoil starter rope pulls hard, yes?
Remove spark plug and see if it's easier. If no change, remove recoil starter and try rotating the flywheel by hand. Comment below for further assistance.