20 Most Recent Hayward 1.5hp Pool Pump Motor Motor A O Smith Electric Pool Motor for 56j Frame Motors Ust1152 - Page 5 Questions & Answers

0helpful
1answer

H200fdn pool water heater. Why doesn't blower start?

its trying to start check voltage to fan if ok bad fan motor if no check safety circuit
12/19/2020 6:22:08 AM • Hayward Pool &... • Answered on Dec 19, 2020
0helpful
1answer

How do you get to centrifugal switch on Hayward PowerFlo matrix

Are you sure it has a centrifugal switch? Capacitor start/ capacitor run have been the standard for a good number of years.
10/26/2019 3:21:48 AM • Hayward Pool &... • Answered on Oct 26, 2019
0helpful
1answer

Manual for Hayward pool products DE 4800

Hayward's website has manuals for all their products.
10/26/2019 3:15:44 AM • Hayward Pool &... • Answered on Oct 26, 2019
0helpful
1answer

I have Sumheat S3 Hayward pool heater I also do not have 24 V output between the blue and yellow cables coming from the transformer. Do I need to replace the transformer? Thanks Cecilia

The 24v is called the secondary and sometimes called the out-put. Make sure you have 240v on the primary, sometimes referred to as the in-put. If you have primary voltage then you should have secondary voltage, if not then replace transformer. Make sure the secondary, 24v control fuse is the correct size and present. If the secondary is shorting together or to ground somewhere, it will cause damage to the transformer.
8/18/2019 11:26:46 AM • Hayward Pool &... • Answered on Aug 18, 2019
0helpful
2answers

I have a Hayward H400 pool heater. I don’t heat my pool so I never use it but I do turn it on once or twice a year for about five minutes to make sure it’s working, which right now it fires up just fine. The problem I am having is once the pump turns off, the blower on the heater turns on & stays on. I can’t get it to turn off unless I cut the power. This is obviously a problem because I can’t have the pump on a timer because as soon as the pump turns off, the blower on the heater will run for 16 hours until the pump kicks back on. I’ve done a lot of research & can’t find a solution or anyone who has experienced this problem. Any advice would be appreciated.

Call a qualified electrician. More information would be needed to accurately trouble shoot your issue. Do you have automation connected to your heater? Is the heater trying to fire when the pump is off or is it ONLY the fan? Try disconnecting your Water Pressure switch on the heater and see if the issue stops. With WP switch disconnected the heater should not work and the fan should stay off. Replace WP switch and see what happens. Call a QUALIFIED electrician.
8/12/2019 3:19:38 PM • Hayward Pool &... • Answered on Aug 12, 2019
0helpful
1answer

I have a Hayward pump it says it has a switch on the pump but I cannot find it where is it located

Underneath the back cap on motor
7/30/2019 2:44:37 PM • Hayward Pool &... • Answered on Jul 30, 2019
0helpful
1answer

Hayward power flo lx pump humming

Check for proper supply voltage and that the impeller moves freely. If these are good then likely a bad capacitor.
7/30/2019 2:42:47 PM • Hayward Pool &... • Answered on Jul 30, 2019
0helpful
1answer

Is it possible to program a Hayward prologic pool controller to run an action every second day? I have aux 6 on a countdown timer and want it to run every second day.

the prologic control unit will not offer programming for what you seek. the most detailed timers will offer weekday or weekend for each pump speed. you may want to get a remote system so you can control functions from your smartphone
7/26/2019 11:34:32 PM • Hayward Pool &... • Answered on Jul 26, 2019
0helpful
1answer

Vapor lock

try filling your hose by holding it in front of the return jet. once filled, hook the hose up as normal
7/26/2019 11:22:41 PM • Hayward Pool &... • Answered on Jul 26, 2019
0helpful
1answer

I have an aqua trol hayward system. I just started it. On the board it says 2,80 and no green lights at all are on. What does it mean

this is a common issue. there is a componant on the circuit board called a voltage limiter. when there are power surges (by hydro company or by using a timer), this capacitor takes the surge to protect the circuit board. in your case, the limiter has blown. you can either replace the circuit board or find someone to remove the limiter and solder in a new one. (its the round black disc to the right of the front display toward the top) in most cases, you will see a hairline crack in the casing or it may have exploded completely. i usually tap it with a screw driver to show customers the damage. FYI: i usually replace about 50 a year and never had one fail
7/26/2019 9:54:53 PM • Hayward Pool &... • Answered on Jul 26, 2019
0helpful
1answer

The rinse setting on my Hayward sand filter does not work,almost like it’s plugged up.Any ideas?

the rinse setting only cleans out the dirty water in freeboard and pushes sand to pack it. just about impossible for it to not work. if there is water coming out the discharge, you are golden.
7/26/2019 9:50:02 PM • Hayward Pool &... • Answered on Jul 26, 2019
0helpful
1answer

Hayward aqua pod error message check system no cell power 2

there is a relay on the back of the main circuit board that has separated from the circuit. you can resolder this relay quite easily by removing the board. DANGER: be sure to cut the power to the control box at the main breaker. turning off the breakers in the hayward box will NOT eliminate the power
7/26/2019 9:45:36 PM • Hayward Pool &... • Answered on Jul 26, 2019
0helpful
1answer

HAYWARD Aqua Rite impossible do diagnostic

i find the aqua rite systems to be very helpful in diagnosing problems. if you can describe the problem you are having, i may be able to help
7/26/2019 9:42:43 PM • Hayward Pool &... • Answered on Jul 26, 2019
0helpful
1answer

Hello, I have a Hayward pool heater Sum heat S3, there is water leaking at the point at which the copper pipe enters the PVC water pipe, does this mean the refrigerant has leaked as well? Thanks

As far as I know, refrigerant is not used in the heating of pools and spas. Sounds like it is just a connection leak and can be fixed by redoing the joint connection.
7/25/2019 2:18:51 AM • Hayward Pool &... • Answered on Jul 25, 2019
0helpful
1answer

My hayward pool pump won't prime,filler the strainer up with water runs fine for a few seconds then the water is sucked in and won't pump

Check to make sure that there is enough water in the pool and that the weir door in the skimmer box isn't jammed in the upright position
7/16/2019 8:30:45 AM • Hayward Pool &... • Answered on Jul 16, 2019
Not finding what you are looking for?
Hayward 1.5hp Pool Pump Motor Motor A O Smith Electric Pool Motor  for 56j Frame Motors Ust1152 Logo

58 questions posted

Ask a Question

Usually answered in minutes!

Top Hayward Pool & Spa Experts

Jay Finke
Jay Finke

Level 3 Expert

1397 Answers

john h

Level 3 Expert

29494 Answers

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Are you a Hayward Pool and Spa Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

View Most Popular

Hayward Pool & Spa

  • Hayward Pool & Spa

Most Popular Question

hayward pump motor hums but start turn

  • Pool & Spa
Loading...