Craftsman 33gal.150 psi air compressor:Start on M/T tank not when full. Start & builds up; then drops down to cut in pressure & kicks breaker when starting up.What can I do to fix this problem.
Sounds like you need a higher current circuit. When a motor starts up, there is a higher than normal current draw, usually 2x to 4x the running current. When it starts up against cut in pressure, there is even more resistance and hence more current draw than when starting up against no pressure in the tank. So, your circuit is capable of providing startup current with no presure, but with pressure it is drawing more current and tripping the beaker. Don't just put a higher rated circuit hreaker in unless you want to buern down your house. Get an electrician to measure the starting current of your compressor and wire up a circuit and outlet that will handle that current safely. That said, the advertising for the compressor says it can run on a standard (15 amp) household circuit, so your motor may be drawing excessive current. Either way, an electrician can help you. Another option is to add capacitive start to the compressor, but, again, a good electrician will have the solution.
919165130 Craftsman Compressor - how to wire for 220V
Check all wring. Remove cove and see if you can turn over by hand.If you can't unit is broken/frozen.it should run on 120. look at the plug if prongs are vertical the unit 120vac. Look on motor wire box if it can be rewired it will be there. I doubt this unit is designed to operate on 120vax. The mots/pump assembly is not available for purchase. there are a few repair parts available. do you want to spend the time and money for rewind.? good luck
My Craftsman 919.166600 compressor takes forever to fill, what would be the issues
Could be piston O rings, worn cylinder line, worn reed valve-plate assembly, worn discharge check valve, leaking unloader valve. Need info if unloader is leaking or unloader tubing is leaking. The Cheapest and quickest is to remove valve plate assembly and inspect valve plate. Suction side should hold water and discharge valve should hold water placed on bottom of plate.
Not finding what you are looking for?