CLEAN UNABLE 5A
printer's purge unit has reached its counter limit and needs replacing
How to reset unable to clean 50 on dcp-j125
Hi,
Try to reset Purge, it just might help.
1. press buttons OK, Menu, Mono Start one by one, followed by up arrow key four times. this should all be done as short a time as possible, around 3 seconds.
2. enter maintenance mode 80 by pressing the up/down arrow key and set key to select numbers 8 and 0
3. press blue MONO start button to select PURGE which requires it to be pressed a number of times before PURGE appears on the LCD screen of the printer
4. then use the up'down key and OK button to enter the reset code 2, 7, 8 and 3 keys to reset the counter : Note this does not overwrite the number next to PURGE on the LCD screen but once the last number is added it gets reset to 0000
5. press Stop/Exit key to go to root of maintenance mode
6. enter 9,9 to exit maintenance mode
Clean unable 46 error on dcp 135c brother printer
Brother error code dcp-j 125 unable to Init 50
hi good day! the printer is error 50 due to a paper or some sensor error.. open the printer, or dismantle, clean the sensor and wash the pump of water and change the waste pad of new absorber. locate the sensor under the pump, clean it of alcohol.
Unable to init 34
Your print head cannot move. Check for foreign material or if the belt came off, motor not working ...
Clean unabel 46
Replace the ink absorber and flushing box and reset their counters