20 Most Recent
Maax Calla 6042 Bathtub - 101058-000 - Page 5 Questions & Answers
Purge line
The breaker the manual is referring to will be the main circuit breaker at the panel.
If the system is not running the purge cycle as it is supposed to and turning the power on and off does not reset the control box then it is likely that the control box has a bad part in the circuity and should be replaced.
Rod
US Parts Center
4/13/2014 11:11:16 PM •
Maax Home
•
Answered
on Apr 13, 2014
Aerofeel does not work on maax tub model 105359-055
I asked the same question to the tech guy at customer service and he said no, because the water detector switch is actually a density switch, so the temperature really doesn't matter. The tub just has to be filed with water.
3/11/2014 1:26:34 AM •
Maax Home
•
Answered
on Mar 11, 2014
In-Line heater does not operate
an inline heater does not heat the water it only maintains the water temperature that is in the bath. try filling the bath with the required water temperature and see if the heater maintains that temperature. good luck
12/21/2013 9:36:07 AM •
Maax Home
•
Answered
on Dec 21, 2013
Not finding what you are looking for?