Bosch PowerStar AE115 Tankless Water Heater... "check elements" Questions

Ad

Question about Water Heaters

1 Answer

correct ohm testing.Two-element water heaters are rated for 240Volts, but can be wired for 120Volts.Check that water heater is receiving power from circuit breaker box.So if breaker is 2-pole 240Volt,

Ad

elements check OK, but water is still to hot, what next a? if elements are getting power, check amp draw. If no amp draw, and element is receiving the correct amount of power, the element is bad. most

Ad

...element recently replaced. Since the repair, I don't seem to have as much hot water available. I checked the wiring and some of the terminals seemed to be lose. I tightened them. However, it ...

...elements. Remove the power wires to the element and then check the resistance across the terminals on the element. If you get resistance the element is good if you get nothing or zero (0) then it is ...

Question about Reliance Water Heaters

1 Answer

...element is not getting any voltage serial number is h96904396 and model number is 8402kr5960 First check that all connections are good. turn off power and take off the cover plates pull out the

Question about Reliance Water Heaters

1 Answer

...while still in the tank and full of water? turn off power then remove covers then check with ohm meter should have same reading on both elements but remove both wires from each element before you ...

...Check the elements, if you have access to a meter to check them. If they are getting power to elements and you have no hot water. The elements are not working correctly. I had some elements check out ...

Question about Reliance Water Heaters

1 Answer

check-- With a clamp around amp meter-- have yo checked to see if the elements are actually drawing current-- This would mean checking the power to the heater, too- If you have voltage at the elements

Question about Rheem Water Heaters

2 Answers

...elements to accurately check an element you will need to drain the heater and cut off the power to it. remove the wires from the element and check resistance across terminals. If it is open then the ...

...check and it should read 5 to 10 ohms on the elements. If this reading is good then the elements are good. Putting in new thermostats should have been sufficient. You need to start at he breaker box ...

Not finding what you are looking for?
Bosch PowerStar AE115 Tankless Water Heater... Logo

51 questions posted

Ask a Question

Usually answered in minutes!

Top Bosch Water Heaters Experts

Colin Stickland
Colin Stickland

Level 3 Expert

22485 Answers

Sheldon Dedek

Level 3 Expert

909 Answers

john h

Level 3 Expert

22486 Answers

Are you a Bosch Water Heater Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...