1998 Lincoln Mark VIII "radiator fan blows fuse" Questions

Ad

Question about Lincoln Mark VIII

1 Answer

Radiator My radiater ele. fan do not work .Evertime I put a Fuse in hight Fuse area the fuse blowes (40) amp and the car run hot. change the fan motor.

Ad

Question about Lincoln Mark VIII

1 Answer

...Radiator fan or AC blower motor? The blower motor will have a fuse and a relay. The radiator fan is controled by the Variable Relay Control Module and temp sensor.... the module is located behind the ...

Ad

...radiator fan on still blows fuse even if the fan is not pluged in just hopeing someone had same problem with theirs just keep[s on blopwing fuse for radiator fan and when a c is on fan does not work ...

radiator fan, shifter lock, and theft control are the circuits on that fuse. I would start with unplugging the radiator fan, and then possibly the ABS, then install a new fuse and see if it pops again

...through one fuse. The short you're looking for will 90% of the time the radiator fan-motor is bad. Unplug the fan then retest fuses. If fuse doesn't blow after unplugging fan, replace radiator

radiator fan relay. the car is a 2001 saturn sl1. The fan may run with jumper wires but if it''s blowing the 30 Amp Maxifuse it's needs a new or used fan motor.It's pulling too many amps.I have almost

Question about Lincoln Mark VIII

1 Answer

...radiator fan fuse after the fan runs for about a minute,i replaced both fan relays and the fuse (fuse several times), this is a 57,000 mi granny car that i just aquired and it is a very clean car i ...

...Radiator fan is not blowing (turn on car and a/conditioner. When compressor kicks in, the radiator fan must blow). If it ims not blowing, the radiator fan motor may be burned out ($40). 2. Check / ...

...radiator fan does not come on and the fuse inside fuse power distribution center keeps blowing, whats my problem also no radio..fuse also blowing Unplug the radiator fan, replace the fuse and see if ...

radiator fan fuse right side is fine but when the left one kicks on it blows the fuse. I disconnected the left one before because it blew the fuse when connected. bought used fans and the same problem

Not finding what you are looking for?
1998 Lincoln Mark VIII Logo

320 questions posted

Ask a Question

Usually answered in minutes!

Popular Products

Top Lincoln Experts

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Thomas Perkins
Thomas Perkins

Level 3 Expert

15088 Answers

Brad Brown

Level 3 Expert

19187 Answers

Are you a Lincoln Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...