Anonymous Posted on Jul 25, 2011

What type of fluid do i use for my convertible top moror?

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1helpful
1answer

Electric convertible top does not completely retract on 1997 328i

check hydraulic fluid level in the hydralic motor pump behind left side trim panel in the trunk.look on side or end of the motor pump assembly.look for screw type check plug. first place rags under the check plug to catch fluid spill unscrew the check plug fluid level should be 1/4 inch bottom of check plug hole if low you need add correct level fluid. then screw in check plug back in place.to bleed air out hydralic system you need helper to hold switch while you raise and lower the top slowly by hand raise and lower top several times to remove air out hydralic system. see if your convertible top will open and close all the way.
0helpful
1answer

2007 MItsubishi eclipse spyder Convertible top stuck open

convertible top could be low on hydralic fluid if you have trouble getting top open or closed.check hydralic fluid hydralic pump located in trunk area look for a screw type check plug on side or end of motor pump assembly.give me more detail about back window panel stuck up.
2helpful
1answer

Convertible top not going up.

LISTEN FOR HYDRALIC PUMP MOTOR OPERATION IN THE TRUNK AREA..IF YES YOU HEAR HYDRALIC PUMP MOTOR RUNNING MAKING A NOISE.CHECK HYDRALIC PUMP FLUID LEVEL BY REMOVING THE SCREW TYPE CHECK PLUG.PLACE RAGS UNDER THE CHECK PLUG.AND UNSCREW REMOVE THE CHECK PLUG. FLUID SHOULD BE 1/4 INCH BELOW THE CHECK PLUG HOLE.IF FLUID IS LOW ADD FLUID UNTIL FLUID LEVEL 1/4 INCH FROM THE PLUG HOLE.IF HYDRALIC FLUID WAS WAY LOW YOU NEED TO BLEED AIR OUT OF THE SYSTEM.MAKE SURE FLUID LEVEL CORRECT.START ENGINE AND TRY RAISING AND LOWER THE CONVERTIBLE TOP USING THE SWITCH.IF TOO MUCH AIR GOT IN SYSTEM.HAVE A HELPER WORK UP AND DOWN CONTROL SWITCH WHILE YOU MANUAL OPEN CLOSE CONVERTIBLE TOP BY HANDS BLEEDING AIR OUT OF SYSTEM.KEEP EYE ON HYDRALIC FLUID LEVEL WHILE BLEEDING THE SYSTEM..LOWER THE TOP AND TURN OFF ENGINE. BEFORE OPENING THE HYDRALIC PUMP FLUID CHECK PLUG BECAUSE FLUID WILL SPRAY EVERY WHERE..IF HYDRALIC PUMP CHECK OUT OKAY AND YOU DO NOT HEAR NO HYDRALIC PUMP NOISE.POWER IS GOING TO HYDRALIC PUMP.EITHER HYDRALIC PUMP MOTOR FAULTY OR FAULTY HYDRALIC PUMP RELAY BEST TO LET MERCEDES BENZ DEALERSHIP CHECK IT OUT...
0helpful
1answer

Need to add fluid to convertible pump resoivour --what type do I use?

This is a special fluid for the hydraulic top, it needs to come from the VW dealer parts dept. Failure to use the correct fluid will distroy all the rubber seals.
5helpful
2answers

1996 audi cabriolet 2.8 V6 convertible top motor needs fluid how do i add the fluid to the convertible top motor?! and what type of fluid does it need?

Almost all power convertible tops are electric over hydraulic. The ecectric motor runs a hydraulic pump. The pump pushes fluid to the cylinders that work the top. Most are located behind the rear seat backrest. Either remove the rear backrest or access the motor/pump from the trunl. It will be shaped like a cylinder. At one is the electric motor, at the other end is the hydraulic reservoir. At the end of the reservoir is a rubber plug. With the top down, remove the plug and fill it with tran fluid till it over flows. replace the plug and cycle the top up and down as far as it will go. Repeat the process till it will take no more fluid. A turkey baster with a piece of vacuum line makes a good filler tool. With that said, you must find the leak. You may have a leaking pump, hydraulic line or cylinder. RNever replace one line. Do them all. Always replace cylinders in pairs.

Good luck, Karl at aoksales.com
0helpful
1answer

My convertible top wont go up

You are probably low on fluid.
Behind the rear seat is the motor/pump/reservoir.
With the top down, fill the reservoir with ATF.
Cycle the system a few times.
Repeat till the reservoir will accept no mor fluid.
Chedk the lines and cylinders for leaks. The fluid must be going someplace.
You can change it to a manual top by removing the bolt at the top of the cylinders and lowering the both shafts down into the cylinders.
1helpful
1answer

Convertable roof Hydrolic Fluid. What type???

Problem solved via fixya,works like new may thanks.
1helpful
1answer

What type of Hydrolic fluid is required to top up convertable roof of Pontiac Firebird 2002

you should be able to use power steering fluid or automatic transmission fluid.
0helpful
1answer

Convertible Top Not Working Properly

This is not a low fluid problem, this a contorl motor problem. I had a 1989 Z24 conv. and the same thing happened. I replaced the motor and the top worked just fine.
Not finding what you are looking for?

61 views

Ask a Question

Usually answered in minutes!

Top Ford Experts

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Thomas Perkins
Thomas Perkins

Level 3 Expert

15088 Answers

xxxxxx xxx

Level 3 Expert

5117 Answers

Are you a Ford Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...