SOURCE: Temperature Control not working on 1999 Ford Explorer
Sounds like your temperature actuator is not moving or your temp door is broken. On max a-c ,coolant is shut off to your heater core allowing only cold air in.
SOURCE: HOT & COLD ELECTRIC VENTS NOT MOVING.
Blend door actuator. When it fails for some reason it turns to the hot side and gets stuck. Dash must come out. I usually do it in 3 hours, because I've done it numerous times.
SOURCE: 2003 ford van e350 rear air vent is not blowing
Try this article. I have the same problem and I think it is the vacuum motor that controls the door for changing from hot/cold in the rear heater box (located inside behind the L rear wheel)
https://www.fleet.ford.com/truckbbas/non-html/Q19.PDF
SOURCE: 2003 Ford Explorer XLT Air Conditioning vents blow hot and cold
It sounds like the control motor switching from hot to cold is stuck halfway in between the two temp settings. You will have to take it down and replace it, it is mounted under dash passenger side near the blower motor.
SOURCE: Why does my Heater blow cold air in the front
its the blend door behind the glove box. I had the same problem