2000 Ford Focus Logo
Donny kipp Posted on Oct 13, 2015
Answered by a Fixya Expert

Trustworthy Expert Solutions

At Fixya.com, our trusted experts are meticulously vetted and possess extensive experience in their respective fields. Backed by a community of knowledgeable professionals, our platform ensures that the solutions provided are thoroughly researched and validated.

View Our Top Experts

What is the source of power applied to blower motor fuse?

3 Answers

loginek

Level 3:

An expert who has achieved level 3 by getting 1000 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Renaissance:

An user who is expert in 3 categories / brands.

  • Ford Master 1,075 Answers
  • Posted on Dec 11, 2015
loginek
Ford Master
Level 3:

An expert who has achieved level 3 by getting 1000 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Renaissance:

An user who is expert in 3 categories / brands.

Joined: Nov 22, 2015
Answers
1075
Questions
0
Helped
1320319
Points
4975

On this website (link below) you find fuse box diagram and description for your car Ford Focus MK1 fuse box diagram Auto Genius

Alex

Level 3:

An expert who has achieved level 3 by getting 1000 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Master:

An expert who has achieved Level 3.

  • Master 387 Answers
  • Posted on Oct 14, 2015
 Alex
Master
Level 3:

An expert who has achieved level 3 by getting 1000 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Master:

An expert who has achieved Level 3.

Joined: Mar 29, 2010
Answers
387
Questions
0
Helped
61913
Points
1441

From ignition switch via relay

Ad

Stephen

Level 3:

An expert who has achieved level 3 by getting 1000 points

Top Expert:

An expert who has finished #1 on the weekly Top 10 Fixya Experts Leaderboard.

Superstar:

An expert that got 20 achievements.

All-Star:

An expert that got 10 achievements.

  • Ford Master 21,873 Answers
  • Posted on Oct 14, 2015
 Stephen
Ford Master
Level 3:

An expert who has achieved level 3 by getting 1000 points

Top Expert:

An expert who has finished #1 on the weekly Top 10 Fixya Experts Leaderboard.

Superstar:

An expert that got 20 achievements.

All-Star:

An expert that got 10 achievements.

Joined: Jun 22, 2012
Answers
21873
Questions
0
Helped
6207948
Points
67230

Power comes from the ignition relay via the key switch.
The relay also powers several other circuits. The key switch activates the relay so that those circuits are not powered directly from the key switch.

5 Related Answers

Anonymous

  • 534 Answers
  • Posted on Aug 31, 2009

SOURCE: blower motor doesn't work and has no power to it

Check the blower multispeed control resistor pack is not faulty.
The resistor pack is usually located in the air ducting, in the blower fan airflow.
Basically, +12v power is supplied (via fuse) to the fan speed control switch, which then passes via the selected speed control resistor, to the fan motor. Often a interface relay is used to switch the blower motor high current.

Ad

Anonymous

  • 1341 Answers
  • Posted on Sep 05, 2009

SOURCE: 1994 ford e350 cargo van, blower motor not working

check if there is any voltage reading at the fan blower wiring when activated,if there is an it still does not work then you may need a replacement blower...

mike hayward

  • 279 Answers
  • Posted on Jan 04, 2010

SOURCE: how to fix heater on ford focus tried a new motor

check the wiring to the reostat (the resistor that controls the fan speed) also check the reostat has not burnt out. (the reostat should be near the heater motor housing)

please let me know if this helps
cheers
big mike :)

Anonymous

  • 1 Answer
  • Posted on Apr 16, 2010

SOURCE: ford 2002 focus blower motor only works on switch

my AC is blowing out hot air and not cool,what do I do to fix this/

Anonymous

  • 1 Answer
  • Posted on Apr 26, 2010

SOURCE: 1999 Isuzu Trooper Problem with Blower Motor, FUse Box, and exter

Did you find out a solution to your problem? I have a 1996 trooper that is showing most of the same symptoms that you have. I'm curious as to your fix. Was it simply a bad ground?

Ad

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

I have a 2006 BMW 650i and my fan has not been comming on Can somebody help me with the exact location of the fan relays???

If your talking about the heater fan, there is a resistor by the blower motor. I don't know for sure about your car, but most are under the passenger side dash. Remove the kick panel and you'll see the blower motor. The resistor is right by it. Before I remove it. I pull the blower plug and put power and ground to the blower , Just to make it isn't the problem. 95% of the time it is the resistor.
0helpful
1answer

Air and heat blower will not come on. 1998 sonoma 2.2l

start by checking fuse. if fuse is good, aquire a test light, check the test light on the battery to make sure the test light works. Power to ground = light. access blower motor under pass-side dash panel.(probablly have to remove underdash cover, secured with pop-in style fasteners.) locate blower motor. 2 wires w/connector Purple-power, black-ground. check for power at purple w/test light on known good ground, with ign on, and blower switch on high. if it has power, hook clip of test light to a power source, ( + on battery w a jumper wire) and probe black wire, with test light. if no light, jumper that wire to a good ground. if it lights, you have a bad b-motor. if no light on power side of blower motor, and fuse is good, check power to swith. blower circuit may have 2 fuses. 1 for high and a 2nd for the lower speeds. if switch has power to it, and power is transfered to another wire when switched, suspect the blower motor resistor. James White, White Automotive, Hopkins Mo. ASE tech, 17 yrs exp.
0helpful
1answer

1999 Park avenue what can make blower stop working?

No it is likely the blower motor is defective, you can test it by removing the connector and then the blower motor and testing it by applying power to the motors connector pins.
0helpful
1answer

Blower motor for air conditioner stop working but when attached to separate power source blower motor works fine, also no fuses are blown.

Most likely either the controls are bad or the blower motor resistor. To check you can see if the controls are getting power and if they are sending power to the blower motor. This will tell you if the controls are bad or not.
0helpful
1answer

Front blower motor will not work in 1994 f 350 van all fuses are good no power anywhere (at switch, resistor, or blower motor in any position

check the 50 amp fuse in teh engine compartment fuse/realy box. Also check the blower motor relay that the fuse protects.
Alos, check fuse 9, 15 amp in fuse panel in truck.

Test by applying 12 volts to teh orange/red wire at teh blower motor connector. Use a 10 or 12 gauge wire with a 25 or 30 amp fuse in line.

report back
0helpful
1answer

1996 ford contour heater blower motor doesn't work. only worked on high before

First, check the blower motor fuse. If it is ok, disconnect the electrical lead from the blower motor, and apply direct power and ground to the motor electric terminals. If the blower motor fails to operate, it is defective. If the blower motor now operates with direct power, but doesn't when reconnected to the car's electrical system, there is likely a problem with the switch, the blower motor resistor, or a bad connection in the wiring. Hope this helps.
0helpful
1answer

1999 Isuzu Trooper Problem with Blower Motor, FUse Box, and exter

Did you find out a solution to your problem? I have a 1996 trooper that is showing most of the same symptoms that you have. I'm curious as to your fix. Was it simply a bad ground?
3helpful
1answer

Why does my blower motor for my 97 silverado does not work?

Check for a blown fuse,
Check for faulty blower motor speed control resistor pack - (usually located in the air flow in the blower ducting),
Check the blower motor is ok; ensure it runs if power directly applied to it.
Check blower motor fan control switch is ok.
Not finding what you are looking for?

315 views

Ask a Question

Usually answered in minutes!

Top Ford Experts

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Thomas Perkins
Thomas Perkins

Level 3 Expert

15088 Answers

xxxxxx xxx

Level 3 Expert

5117 Answers

Are you a Ford Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides