I have a masda BT 50 2010 model. The blower fan does not work. Can you help with trouble shooting. Blower motor is ok I tested it on a separate 12 v supply

1 Answer

David Harrelson

Level 3:

An expert who has achieved level 3 by getting 1000 points

Superstar:

An expert that got 20 achievements.

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

  • Cars & Trucks Master 5,456 Answers
  • Posted on Jan 26, 2015
David Harrelson
Cars & Trucks Master
Level 3:

An expert who has achieved level 3 by getting 1000 points

Superstar:

An expert that got 20 achievements.

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Joined: May 06, 2008
Answers
5456
Questions
17
Helped
1101035
Points
15442

Check switch and ballast resistor and fuse.

  • Riaan Jan 27, 2015

    I have tested the blower fan resistor all ok

  • David Harrelson
    David Harrelson Jan 27, 2015

    I think all that is left is the switch. Can you test to see if it is getting power and if it passes it on?

×

4 Related Answers

Anonymous

  • 8 Answers
  • Posted on Dec 21, 2008

SOURCE: 2000 ford explorer fan blower only works intermittently

On ford vehicles the blower motor resistors are the most common problem when this happens.

Ad

Anonymous

  • 5158 Answers
  • Posted on Jan 15, 2009

SOURCE: heater blower on my jaguar xj6 (x350 ) model not working

check the fan speed resister block... located under the dash in the duct work near the fan. i may have failed

Robert

Anonymous

  • 962 Answers
  • Posted on Jan 25, 2009

SOURCE: trouble shooting blower motor on 1997 dodge gran caravan

Check the heat/ac relay first making sure it is working.remove it clean the contacts and reattach. Then check the Resistor component. It is usually located near the blower or on the blower motor itself.It is attached with a couple of screws and a plug between the blower motor and the wiring. Please vote if this helps you.

Anonymous

  • 107 Answers
  • Posted on Feb 19, 2009

SOURCE: Lincoln 2000 town car Blower doesn't work at HI-MED-LOW speeds...

it is called blower motor resistor , should be close to blower motor , you will see a plug type connector with two screws , remove the screws and there should be a resistor inside the cover for the motor, swap with new and reassemble

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

Blower will not work replace blower and relay

Testing the electrical circuit is the proper way to diagnose a non working blower motor . There are videos on youtube showing how to do trouble shooting . Blower Motor Problems Auto Repair Help
0helpful
2answers

A/c blower motor works if I pull power and plug back in until I cut engine off. Then I have to repeat process

Daryl, You may want to check the blower relay/ just switch with one of same type and try and if OK, problem could be the blower motor, wires/plug loose,damaged,burnt or a faulty blower motor resistor. Second link has some trouble shooting of a overheating wire problem, that is to be common in these trucks. Check the attached links,instruction and guides, Good luck
"I hope this helped you out, if so let me know by pressing the helpful button. Check out some of my other posts if you need more tips and info."
DIY 2003 Silverado Blower Motor Resistor
Sparkys Answers Chevrolet Silverado Blower Does Not Work On Any Speed
03 Silverado heater fan problem ChevyTalk FREE Restoration and Repair Help...
0helpful
1answer

I need to know the location of my blower relay. Already changed out the blower resistor, that did not remedy the problem (fan will not come on). Yes, I installed it correctly.

The blower relay is for high speed fan only most of the time . Do you know how to test electrical circuits ? It sure cuts down on buying unneeded parts . Here watch this video , this is a Chrysler vehicle . Don't know what you have , doesn't matter . They all work pretty much the same . I suggest you watch a few other trouble shooting videos as well .Is Chrysler Blower Motor Test subscriber requested video This next vehicle is a GM product , this one uses a relay for high blow only . Blower Motor Problems Auto Repair Help

0helpful
1answer

2010 DODGE caravan a/c blower fan inop have replaced reistor and control head rear fan works have checked all relays and fuses

Hi Jim, I will try my best to help you. First off, let see what we are losing at the blower motor. Three things I want you to do. #1-With a multi-meter check the power side at the blower motor connector and see if you have a full 12 volts. #2-With a test light hooked to the battery positive terminal, check the ground side at the blower motor connector to see if you have a good ground, the test light should be good and bright. #3-With the multi-meter set on ohm's check across the actual blower motor connector a resistance reading of up too 7 ohms is OK, but if you have a reading above like 14 to 22 ohms then replace the motor. Hope this helps and have an awesome day Jim!
0helpful
1answer

Trouble shoot heater fan on a 1996 Plymouth Voyager Van

Check for 12 volt power to resistor under dash on passenger side. Follow wires from under glove box (from blower motor) to resistor, which will be where wires are connected on duct work. You should be able to test for 12 volt DC power there.
0helpful
1answer

Trouble shoot blower motor switch

Often times the problem is the blower resistor not the switch.
You would use a meter or a test light to check for power at the resistor and also the switch. The resistor controls power to the blower motor to adjust speed.
0helpful
1answer

Blower not working. have replaced the motor resister. what next? Does anyone know how to trouble shoot this system?

REPLACE BLOWER MOTOR RELAY.HOOK TEST LIGHT SEE POWER GOING TO BLOWER MOTOR IF YES BLOWER MOTOR FAULTY.IF NO POWER GOING TO BLOWER MOTOR, FAULTY RELAY, FAULTY CONTROL SWITCH OR POOR GROUND AT WIRE TO BLOWER MOTOR.
2helpful
1answer

Heat fan stopped working..is it a fuse?

Hi!!
It could be the Blower Motor Fuse or Relay and they should be located in the cabin Fuse Box, if both are OK, it could be the blower motor resistor, located on the blower motor housing, it is the part where the electrical connector goes into and it's got a pigtail connector that goes to the blower motor, it is attached to the blower housing by three screws. Here are some pictures for better identification.
FRONT VIEW 1kbron_5.jpg
CONNECTOR FROM RESISTOR TO BLOWER MOTOR 1kbron_6.jpg
SIDE VIEW 1kbron_7.jpg

To test it, make sure the electrical connector has voltage when the FAN is on, if voltage is present, it means relay and fuse are OK, plug the connector into the resistor and check voltage on the pigtail connector, if voltage is present, the resistor is OK, voltage varies according to the speed selected. To check the blower motor, apply 12 volts and ground the the motor terminals, it should kick in in Hi speed, if not Replace Blower Motor.
A HELPFUL - 4 THUMBS - rating for this solution would be greatly appreciated. Thank you for using FixYa.
7helpful
1answer

Heater/AC Fan does not work in our 1998 Buick Century

Fan will be under dash on passengers side , Removing glove box might be needed, Gm also uses a blower resister ro control fan speeds. First check your fuse and then check and make sure your getting 12 volts to the terminal at the blower, You could have a blown fuse, a bad switch, or a bad resister , if your getting voltage to blower motor then most likely it will be the motor. These are not to difficult to change. I hope this helps, please be aware I can only guess at what the problem is from my past experience.
0helpful
1answer

1995 ford explorer blower motor

Basically, you have a fan relay that has shorted and burned. The relay is used because of the different power setting needed for the fan speeds.

Trouble shoot all fuses, incase you blew a fuse when the relay went. The relay burned but that did not effect the motor, thats why the motor runs well.

To find the location of the hi speed fan relay, check with your local parts store to see if they can bring it up on a computer.

Bill
Not finding what you are looking for?

1,414 views

Ask a Question

Usually answered in minutes!

Top Cars & Trucks Experts

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

john h

Level 3 Expert

29494 Answers

Arnie Burke
Arnie Burke

Level 3 Expert

7339 Answers

Are you a Car and Truck Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...