My fan is not working. It did work on settings 3 and 4 for a long while, and now has stopped altogether. It is not the blower motor ... that didn't solve the problem. It could be the switch. I am wondering what I should expect the cost of it to be, to replace the switch - parts and labor.

1 Answer

Jeff Armer

Level 3:

An expert who has achieved level 3 by getting 1000 points

Superstar:

An expert that got 20 achievements.

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

  • Hyundai Master 15,575 Answers
  • Posted on Dec 11, 2017
Jeff Armer
Hyundai Master
Level 3:

An expert who has achieved level 3 by getting 1000 points

Superstar:

An expert that got 20 achievements.

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Joined: Nov 22, 2012
Answers
15575
Questions
1
Helped
7104750
Points
73899

Doubt it's the switch ,but you never know until testing is done . Do you know what that is ? Automotive systems electrical testing , view a wiring diagram too see what all is involved in said circuit ,an using a DVOM - digital volt ohm meter to test B+ voltage an ground ? Looking at the wiring diagram for the blower motor circuit for your vehicle i see a blower motor relay , a blower motor resistor pack an the blower motor switch . The switch is just a path to ground . If it doesn't work on high speed i would suspect the blower motor relay . View the wiring diagram here
http://www.bbbind.com/free_tsb.html Enter your vehicle information , year , make , model and engine size. Under system click on HVAC ,then under subsystem HVAC controls will come up on it's own . Click the search button then the blue link . Buy a cheap volt meter an test the circuit . That is after watching these videos .
Electric Testing Techniques You Need to Know
The Trainer 32 How To Read An Automotive Block Wiring Diagram

Learn how to test an save money , it's easy ! Is there B+ voltage at the relay .Also check out how a relay work's an how to test .

3 Related Answers

mastertecmec

Keith Hirsch

  • 42 Answers
  • Posted on Jan 25, 2009

SOURCE: blower fan

Sounds like the problem is more with the blower motor assembly itself. The blower motor have micro-proccers built itnto them which comunicate with the control heads and do the actual regulating of the fan motor. Dealers have computers with diagnostic software which allows them to monitor what is happening in the eletronic controls of the vehicle. Electronic diagnostics without the diagnostic software makes it very diffecult to pinpoint the actual item causing the problem.

Ad

Anonymous

  • 55 Answers
  • Posted on Jun 07, 2010

SOURCE: My heater and ac fan speed is not working is the

Your blower motor is probably fine, it is the electronic mechanism that governs the speed of it that has gone haywire. Call the dealer and asked them where it is and how much. Then go to a junkyard and grab one.

raj somaiya

  • 5370 Answers
  • Posted on Feb 19, 2012

SOURCE: I have a 2002 hyundai santa fe and the blower motor has stopped working. I have replaced the blower motor and the resistor with brand new parts but the fan still does not work. When I turn the fan on

Yes both relay and switch are possible.Needs to be inspected.
Blower motor replacing for all vehicles? http://repairhelpcenter.blogspot.in/2012/02/blower-motor-replacing-for-all-vehicles.html

Blower motor Resistor shorting problem?

http://schematicsdiagram.blogspot.com/2011/12/blower-motor-resistor-shorting-problem.html

How to remove Blower control switch? http://howtobyme.blogspot.in/2012/02/how-to-remove-blower-control-switch-on.html

---------

Where is blower motor relay located ? http://technoanswers.blogspot.in/2012/02/where-is-blower-motor-relay-located-on.html

--------

This will help.Thanks.

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

I have a 2002 Pontiac Sunfire. My fan stopped producing air (hot and cold altogether) - from the lowest setting to highest setting does not work.

HI,
sounds like a the heater/ blower fan relay went bad. Unless you're mechanically-inclined you'll need a mechanic to install the replacement.

Do a Google search for the relay or blower motor and/or search for a Chevy Cavalier (same car) forum to find a fix - if you want to tackle it yourself.

GL,
TD
0helpful
1answer

2003 mitsubishi outlander heater fan doesn't work, how might I fix it?

either bad blower motor resistor (least expensive fix to atempt) , or blower motor bad or electrical circuits to motor
0helpful
1answer

My bmw 318 is blower fan not working

Blown Fuse
  • Usually the first thing to inspect when the blower fan stops working is the fuses to see if any are blown. Locate the 10A cluster fuse or the 25A HVAC fuse in your car manual, and examine them to determine if they need replacing. The car owner's manual will tell you where to find the fuses that are connected to the heat and/or air conditioning. On the interior fuse panel of the car, a 30 amp fuse is labeled "Heater" or "HVAC."

Bad Blower MotorIf the fan only works on setting number 3 or 4, or just on the highest setting, it is most likely that your blower motor is failing and is about to die. Use a voltmeter to test the amount of voltage at the blower motor connector with your ignition on and AC running. If it reads 12V, the motor needs replacing.Automatic Climate Control SystemAnother thing that causes the blower fan to malfunction is the Automatic Climate Control System (ACCS). If the ACCS's settings are off, it may cause the fan to stop working. If it is the climate control on the car, typically it is a bad thermostat or electrical circuit that is the culprit.
hope this helps, James Booth
0helpful
1answer

The fan on my heater/ac stop working on settings 1-4 for awhile it worked on #5 but has now stopped altogether

The blower resistor has gone out but if blower is no longer working on speed 5 then either the blower motor is bad as well or the pigtail connector to the motor are bad. Check the plugs to the resistor and to the blower motor for insulation damage discolored or melted wiring.
0helpful
1answer

Heater control for fan blower not working. stopped working for about a day then started working again for a day then stopped altogether dead since.

check the blower motor relay, located under the hood fuse/relay box. turn the system on and tap the blower motor see it works. The blower motor located under the glove box.
2helpful
1answer

The HVAC blower fan on my 2001 Pontiac Aztec stopped working on settings 1-3 several weeks ago. Last week it stopped working at setting 4 and today it stopped working all together. What is the most likely...

the blower not working on settings 1-3 is the blower motor resistor. this limits the power provided to the blower motor itself to change the speed. at setting 4 it is getting full power. since it quit on 4 also, i would still say the resistor needs to be replaced first, then see if the blower comes back. you may also need a blower motor. if you have a voltmeter you can just turn the switch to 4 and see if the motor is still getting 12 volts. if it is and doesn't run, it needs a blower motor too. if it's not, then its just the resistor
9helpful
2answers

Focus 2002, A/C fan does not work on settings 1-3

common problem, replace the blower motor (fan) resistor, this is what controls the fan speed,its located on heaterbox next to blower motor.heres a picture of it,its on the rightside of dash toward the bottom. hope this helps.852ab4f.jpg
1helpful
1answer

My blower fan only worked on the 5th setting for the past year now it stopped altogether how do i fix this problem

hook a direct jumper wire to to blower motor itself and make sure it still functions and it so then check the blower relay and the blower grounds also check and change the blower temp controller resistor in the Ac box
1helpful
1answer

Heat blower fan not working

it seems like u have either a bad switch or bad blower motor.
3helpful
2answers

2002 Ford Taurus blower fan only works on high

fords are notorius for faulty fan switches, you will need to get a new one, but it will probably fail in a year or two.
Not finding what you are looking for?

133 views

Ask a Question

Usually answered in minutes!

Top Hyundai Experts

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Ronny Bennett Sr.
Ronny Bennett Sr.

Level 3 Expert

6988 Answers

Thomas Perkins
Thomas Perkins

Level 3 Expert

15088 Answers

Are you a Hyundai Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...