2000 gmc 2500 pickup heater fan works good but not a lot of air
Moves thru the vents the defroster moves more air but the dash vent dont work well at all floor heat not great truck temp 210 everything seems to work just not much air movement
- If you need clarification, ask it in the comment box above.
- Better answers use proper spelling and grammar.
- Provide details, support with references or personal experience.
Tell us some more! Your answer needs to include more details to help people.You can't post answers that contain an email address.Please enter a valid email address.The email address entered is already associated to an account.Login to postPlease use English characters only.
Tip: The max point reward for answering a question is 15.
If the compressor is running and one of the ac lines is cold, you probably have a blend door stuck or faulty in the HVAC box under the dash. The blend doors direct air thru the heater core and evaporator core as well as thru the vents.
Under neath the venting system behind console there is a venting housing that can be removed. Likely the air flow directional vent flap is stuck or the motor that moves the vent is faulty.
good work, the clicking noise you hear is the blend door trying to move. this door is what controls the temp. the most common reason is the actuator motor is bad but sometimes the door hinge breaks, this hinge slides into actuator and is used to move the door. you will need to locate it on the heater box by locating the noise and then remove the actuator and see if the hinge is broken, i will try to enclose some picture to help you. good day, hope this helps.
It is a vent door actuator motor on top of the blower box,the dash has to be removed and set in the seats to replace the actuator motor.Cost for the part is about 50.00 dollars
sounds like bad acuator motor, this is what moves the door in heater box to set hot or cold air, and other motors to set air to blow thru defrost, vent or floor. good luck.
×