Farley Redfield posted an answer for this Maytag Dryers:
"A thermal fues has to be in the main line wiring on one of the lines feeding the element...."
Farley Redfield posted an answer for this Kolpak Freezers:
"Find a service mechanic you trust and get that door FIXED. the ping pong ball is to allow..."
Farley Redfield posted an answer for this McCall Freezer 7-7045FT:
"My first question is, who worked on it before? you are discribing a moisture restriction...."
Farley Redfield posted an answer for this True Refrigeration True 871782 Replacement Shelf for T-72 Reach In Refrigerator & TM-74 Reach In Refrigerator:
"Must have the operation manuals. Consult with True and may have it for a down load"
Farley Redfield posted an answer for this Frigidaire Freezers:
"That yellow light on sonne older modelks is just showingbtge power is on. I never heard of..."
Farley Redfield posted a question about Chrysler Cars & Trucks:
"Where can i buy a wire diagram for 2001 town and counry?"
Farley Redfield posted an answer for this Kenmore Freezers:
"It may be a sensor. Don't replace a control center unless you have determined it's bad...."
Farley Redfield posted an answer for this Kenmore Freezers:
"Go to Sears.com enter your model number son where on that site I have seen the manuals..."
Farley Redfield posted an answer for this Heating & Cooling:
"Could your letter be a F instead of a P? F3 Indoor unit. Red LED, Outdoor flashing 6..."
Farley Redfield posted an answer for this Dayton Heating & Cooling:
"Usually the nutural is in the power cord box beside the hot. The ground is also there but..."
Farley Redfield posted an answer for this Heating & Cooling:
"I dont know. I have to see a picture of both areas."
Farley Redfield posted an answer for this Heating & Cooling:
"Chances are that the unit and new control have to be paired or reset to each other. Or The..."
Farley Redfield posted an answer for this Heating & Cooling:
"Try unplugging it for 5 min? If this dont work try something else in the plug to see if..."
Farley Redfield posted an answer for this Heating & Cooling:
"I suspect it means it is in the a.c. mode. look inside the thermostat for an 800 tech..."
Farley Redfield posted an answer for this Coleman Heating & Cooling:
"First you have to have a volt ohm meter. next you touch your leads to each switch with the..."
Farley Redfield posted an answer for this Heating & Cooling:
"Check voltage at the units connection point. If 230 v there then the heater is defective...."
Farley Redfield posted an answer for this Refrigerators:
"Unplug it. Try removing the wire plugs from the board. Look for corrosion on the wire and..."
Farley Redfield posted an answer for this GE GDS18SBPLSS Bottom Freezer Refrigerator:
"Check the defrost limit switch. I always replace it with the heater. Then check the..."
Farley Redfield posted an answer for this Heating & Cooling:
"Assuming the polarity is correct I. E Black to L1 white to N and green is grounded and the..."
Farley Redfield posted an answer for this Heating & Cooling:
"FAULT = ELECTRIC CURRENT IS TOO HIGH. CODE = P2 CHECK POINT = 1. CHECK IF THE REFRIGERANT..."
Farley Redfield posted an answer for this Heating & Cooling:
"A Mitsubishi $ystem an E8 means low cooling or heating performances. This could be ; low..."
Farley Redfield posted an answer for this Heating & Cooling:
"Easy, look at your compressor. The large line will come out and go directly into the house..."
Farley Redfield posted an answer for this BMW 2004 330 Ci:
"An open wire or incomplete connection at the fuel pump plug. Try unplugging the wiring and..."
Farley Redfield posted an answer for this Heating & Cooling:
"You might put in gas logs or an electric log :-P. You could consider a Ductless mini split..."
Farley Redfield posted an answer for this Heating & Cooling:
"Requires mfg name"
Farley Redfield posted an answer for this Windchaser PACR10 Portable Air Conditioner:
"Need manufacturer model and serial numbers"