Vollrath granita vcbf168 3 head machine slush machine one of the augers isn't turning but can see inside the cylinder the auger drive is turning

If one of the augers in your Vollrath Granita VCBF168 3-head slush machine is not turning, but you can see that the auger drive is turning, there may be a few possible causes for this issue:
  1. Auger blade or shaft issue: Check the auger blade and shaft for any damage or obstruction. Make sure the blade is properly attached to the shaft and rotates freely. If there is any damage or blockage, you may need to replace the auger blade or shaft.
  2. Belt or pulley problem: The auger drive is typically connected to the auger itself via a belt and pulley system. Inspect the belt and pulleys to ensure they are intact and properly aligned. If the belt is worn or the pulleys are misaligned, it may prevent the auger from turning. Adjust or replace the belt or pulleys as needed.
  3. Motor malfunction: The auger drive motor could be experiencing a malfunction. Check if the motor is running smoothly and listen for any unusual sounds. If the motor is not functioning properly, it may need to be repaired or replaced.
  4. Electrical issue: Ensure that the electrical connections are secure and there are no loose or damaged wires. Check the motor's power supply and voltage to ensure it is receiving the correct amount of power. If there is an electrical problem, it may require professional repair or assistance.
6/24/2023 10:31:53 PM • Vollrath Kitchen... • 30 views • 0 helpful votes
0helpful
1answer

I have a 30 quart Vollrath floor mixer that won't start. It ran fine before being put into storage but now I can't get it to start mixing.

Question edited for clarity. Question moved from Televisions. You have a fault that no one else has encountered. Call for service https://www.google.com/search?q=30qt+vollrath+floor+mixer%2C+no+start ..
7/4/2022 11:17:52 PM • Vollrath Boxer... • 200 views • 0 helpful votes
1helpful
1answer

Where can I get a wiring diagram for a vollrath hs1220 food warmer?

You could try calling them in the USA at 800.628.0832 in the Eastern Time Zone. They do list several different Cayenne Model 1220 variants at: http://vollrath.com/Cayenne-Model-1220-Full-Size-Heat-N-Serve-Rethermalizers-1157.htm There is a video on Cayenne Warmers - Heating Elements at: http://vollrathuniversity.com/vollrathUniversity/Product-Training/Countertop-Warming-and-Display/Cayenne-Warmers-Heating-Elements.htm
6/3/2014 12:32:48 AM • Vollrath Food... • 298 views • 1 helpful votes
0helpful
1answer

Where can I find a manual for Sheffield Deep Fryer model PLA0421

Try Ebay.com. Or contact the manufacturer.
6/6/2014 3:15:38 AM • Vollrath 40705... • 132 views • 0 helpful votes
0helpful
1answer

The switch doesn't work on my grinder. got new one but terminals are different. is there a schematic for min0022 or 40744 grinder?

Best you contact the manufacturer so you do not burn out the motor by mistakenly attaching to the wrong posts.
3/14/2014 11:51:52 PM • Vollrath 40744... • 275 views • 0 helpful votes
1helpful
1answer

Got a brand new vollrath warmer product number

Do you mean to say you just plopped 800 bucks, picked up the warmer, said thank you, and walked out without asking any questions?

faxmando_9.gif

.
7/1/2011 4:54:21 AM • Vollrath 40734 • 103 views • 1 helpful votes
0helpful
2answers

I do not have a problem with the deep fryer, I

http://www.bakertowne.com/servlet/the-824/Vollrath-40705,-40705,-Commercial/Detail

At the bottom of that page are several manuals in pdf format.Just click on the above link,then scroll down to the appropreate manual and click,follow prompts.
5/13/2011 12:43:31 AM • Vollrath 40705... • 134 views • 0 helpful votes
0helpful
1answer

Finding reset switch for vollrath

Reset switch (hi-limit reset button) is usually located at the back panel of the unit if it has a reset button design.If the hi-limit activates and does not have reset a button, you have to wait for the oil temperature to cool down and it will automatically reset.
3/26/2011 6:14:15 PM • Vollrath 40707... • 417 views • 0 helpful votes
0helpful
1answer

How can get a manuel for the Vollrath 38004 Hot

Here it is http://www.vollrathco.com/files/documents/282.pdf
12/8/2010 5:49:14 PM • Vollrath 38004... • 169 views • 0 helpful votes
0helpful
1answer

How does electric heater works

A Heater, is a real simple circuit. There are only TWO "Active" wires in any Electrical Circuit, the Phase, Positive, & Neutral, Negative, usually Negative & We also have an Earth, the Earth & Neutral are at the same, "Potential", IE:0 Volts. So imagine it like this, from the left we have a a Power wire, the Phase, this Wire, goes to One terminal on the On/Off Switch, this is called the "Hot" side, of this switch, This switch, when operated, "Breaks" the Phase line, or circuit, From the other terminal,the "Cold" side of the Power Switch, That wire, circuit, then goes from that "Cold" side of that switch, usually, to a "Thermal Fuse", wired in "Series" this "Fuse" is "Normally Closed", when/if, there is an "Overheating Condition", this "Device" will go "Open Circuit". Thus Breaking, the Phase Power, OFF, from the "Element", or "Load". Connection. This wire then goes, from the other terminal of that "Fuse" to the "Hot" side of the "Element". Now the other side or "Cold" side of the "Element" or "Load" then goes to "Neutral", or, return. Thus the circuit is now complete. Now the Earth, the MOST important wire, is bonded to the/any metal case &/or fittings of the unit, thus any "Hot" wire that may break, or touch, the "Earth" will cause a "Short Circuit" to Earth,and "Blow" the Circuit Breaker or Fuse on the Main Power Board. Thus affording protection from shock. Troubleshooting is simply following continuity along the circuit path, and the measuring of the On/Off components for integrity, and the/any "Fuses" and the "Resistance" of the Elements. This can be worked out from OHMS LAW, Volts = Amps multiplied by Resistance. Watts = Amps x Volts. From those two simple calculations we can glean the "Resistance" of the "Load" and what it should be. Then we can measure against that to see if there is any disparity, which would indicate the fault. EG: We have a heater it is 2000 Watts, it is in USA and the Voltage there is 120 Volts. First we must get our Current draw, we then divide the Wattage by the Voltage to get our Current draw. In our case, it is, 16.66 Amps. Now we know our Amps we can workout the resistance of what our Elements will/should be. Now we Divide the Voltage by the Amperage to get this figure, which is 12 OHMS, if there were 2 elements they would simply be 6 OHMS each. Now sometimes heater have a "Thermostat" this device is Powered from the line, and using temperature sensing, it will act like a switch, that is turned on & off, when a "Condition" is met. It simply Breaks the Phase to the "Load" These "Contacts" are in series, with the Phase, and "Act" just like a/the power switch. We look for "Open" circuit where it should be "Closed" and "Closed" circuit where there should be "Open", also the "Resistance" of the "Elements" or "Load". So basically we are looking for, "Open" or "Short" circuits.
3/2/2010 3:25:43 AM • Vollrath 46115... • 77 views • 0 helpful votes
Not finding what you are looking for?

Ask a Question

Usually answered in minutes!

Top Vollrath Experts

Anonymous

Level 2 Expert

300 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66835 Answers

Oscar Sta Ana Jr

Level 2 Expert

77 Answers

Are you a Vollrath Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...