I have a sta-rite inground pool heater Therm-max
You should not have any gas at the union until the heater tries to fire. The Air Flow Switch circuit should have 24 volts at the switch and should be tested. If the voltage is not correct then more trouble shooting will need to be done.
I have a heater problem,
Have any mice been inside the heater? If so check the burner. Some times the mice will nest inside the burner and it will need to be cleaned.
5/12/2017 9:48:03 AM •
Sta Rite...
•
900 views • 0 helpful votes
How to clean impeler on sta rite
Not sure you should do this, what are the deposits you are trying to clean off? If they are hard deposits like minerals then medium blasting with a material like ground walnut shells will clean it up.
Where to add water to prime pump ds3hf-01 sta rite
water is filled in the body of the pump to prime it
fill the filter housing if that is part of the pump
make sure that there is no open pipes /hoses or air leaks on the suction side of the pump and that includes any vacuum machine hoses floating on the water surface
What causes my 2000 Buick lesabre to stall while drive.
first thing I would check is you should check for spark next the fuel filter, take it off shake it and dump out the contents if its dirty, this could be the problem, also you can place your ear against the car and cycle the ignition switch you should hear a buzz, this is the fuel pump running, it only runs for about 5 seconds, unless the car is running.