Error 30 shows when i
Any 30 series error code means that their is no communication between upper and lower boards.
The main Telco harness ( looks like a telephone or DSL wire) my have a bad or broken connection. Unplug unit and taken motor shroud off and check connections should be able to plug and unplug same goes with upper console. If this does not help then either call a local service provider or call Precor directly give them the Model# and Serial# for this unit. They should provide you with the additional info needed
Good Luck!!
MAX
Error 27
Precor Error 27, Too Much Drive Motor Current
Probable Cause
1. The running belt and/or deck are badly worn.
2. Drive motor is shorted or de-magnetized causing a high power demand.
Corrective Action
- Check the amp draw using a clamp on AC volt-amp meter during loaded and no load conditions and compare values to a similar treadmill that is known to have a good running belt and deck. Replace the belt and/or deck if necessary. Don't forget, some units have a double sided deck which means it may be flipped over rather than replaced if it has an unused side.
- Test unit with a known good drive motor. Replace drive motor if necessary.
Precor Error Code 27
What is error code 30 mean on the precor 9.32i treadmill?
Precor Error 30, 31, 32 and 33, Communications Error
Probable Cause
1. Bad interconnect cable between upper PCA and lower PCA.
2. Interconnect cable is mistakenly plugged into the CSAFE connector at the upper PCA.
3. Elliptical 5.17 equipped with old software version 1.01 in upper and lower PCA.
4. Upper and lower PCAs have mismatched software.
5. Another component plugged onto the PCA is overloading the +5VDC power supply.
6. Bad lower PCA.
7. Bad upper PCA.
Corrective Action
- Test unit with a know good interconnect cable or test the interconnect cable for continuity. Replace interconnect cable if necessary.
- Disconnect the interconnect cable from the CSAFE connector and attach to the proper position on the upper PCA.3.
- Replace the upper and lower software of the 5.17 elliptical with the most current versions.4.
- If one of the PCAs is found to have software version 1.01, replace it with the most current software version.
- Disconnect all components from the upper and lower PCA leaving the data cable connecting between the upper and lower PCAs and the AC power going to the lower PCA. If the unit shows any error other than the error 3x, reconnect components one at a time. Reset power between each newly connected component until the error 3x reappears. Whichever component was last connected when the error 3x reappears, is the cause for the error. Replace the faulty component.
- Test unit with a known good lower PCA. Replace the lower PCA if necessary.
- Test unit with a known good upper PCA. Replace the upper PCA if necessary.
Precor Error Code 30 31 32 33