Precor Logo

Precor Recent Questions, Troubleshooting Help & Support

Do you work here? Claim your company

  • 167 Products
  • 909 Answers
  • 95K Views

If it can be recharged it needs to be but only on a trickle charge over a lone time even a week at very low amps like 1 or 2 no more than 6 amps good luck

Precor Exercise... | Answered on Jan 19, 2019


II just started 6 weeks ago and I've gotten 2 check for a total of $2,200...this is the best decision I made in a long time! "Thank you for giving me this extraordinary opportunity to make extra money from home. This extra cash has changed my life in so many ways, thank you!"
Visit site: http://S­­­­­­a­­­­l­­­­a­­­­r­­­­y­­­­­­H­­­­D­­.­­C­­o­­M

Precor Exercise... | Answered on Dec 16, 2018


If you wish to get some details; check the site linked here. Pull up older posts for treadmills . Surf the site with patience.
http://electro-medical.blogspot.com/

Precor C956i... | Answered on Aug 21, 2018


overlay need to replace .. first interchange the uPCB and checked

Precor EFX 5.21s... | Answered on Aug 11, 2018


Precor Error 50, Too Much Brake (Magnet) Current Probable Cause 1. Shorted or damaged wiring between the lower PCA and the eddy current magnet is the most common cause for this error.
2. Bad eddy current magnet.
3. Bad lower PCA.
Corrective Action
  1. Thoroughly inspect the eddy current wiring and connections ensuring that the wires are not shorted to the frame or shorted together. Repair or replace damaged wiring as necessary.
  2. Disconnect the wires from the eddy current magnet. Using an ohm meter, check for approximately 100 ohms across the eddy current magnet terminals. If the reading is considerably low, replace the eddy current magnet. Measure ohms between each eddy current magnet terminal and the frame ground. You should have no resistance between the eddy current magnet terminal and the frame ground. If resistance is present this would indicate a partial short, replace the eddy current magnet.
  3. If the eddy current magnet wiring and the eddy current magnet are both good from the above tests, replace the lower PCA.
Error 50 Too Much Brake Current on Precor Cardio Equipment

Precor Exercise... | Answered on Apr 25, 2018


Try Googling (precor)(9.33)(manual) without parens,

Precor Exercise... | Answered on Apr 10, 2018


Hi There,

Precor uses a pair of Triacs to drive the lift up and down. These triacs live on the lower board but are driven by the upper console commands via a serial link between the upper and lower. Most precor lift issues we see are related to the lower board but with Precor it could be an upper board or the CPU Chip that resides on the lower board or a failed Triac. Good Luck

Precor Exercise... | Answered on Feb 20, 2018


Proform Treadmill Incline Problem Fixed
pLEASE Test fo 120 vac forward and backward
2) if there are voltages coming from controller boad motor the inclination motor is fault or capacitor
3) If there are not the controller board motor is fauty
3) However are some treadmill working with relais see if this relais are coming up in the respective board, if Do not see if there some fuse faulty and replace, if there are good the board is faulty for incline motor.
Blessing
cuadra2016@yandex.com
cell+whatsApp: +50588611441

Precor Exercise... | Answered on Jan 29, 2018


Elliptical fix
However if you machine use battery replace the batteries by Alkaline type, cleant the contacts spring with contact cleaner electronics.
Let me know
Blessing
cuadra2016@yandex.com
cell+whatsApp: +50588611441

Precor Exercise... | Answered on Jan 25, 2018


Troubleshooting Treadmill Control Panel Issues Green Fitness Company
However test the voltage supply from Control Board Motor to the PCB console, by 8-12Vdc, if does NOT appear replace the Control board motor.
If there are Replace the Console Board Display.
Blessing.
cuadra2016@yandex.com
cell+whatsAPP:+50588611441

Precor Exercise... | Answered on Dec 11, 2017


If you are using Electrical power coming from outlet box 110vac, The Power supply inside is defective. Or if you are using batteries, has the same problem with the converter-power supply, Repair or replace.
Blessing.
cuadra2016@yandex.com
cell+whatsAPP:+50588611441

Precor Exercise... | Answered on Nov 03, 2017


Is very simple. Under the console or display, are some small cover , Press the small tab and you will 2 spring where is located the batteries.
Put some contacts cleaner for electronic, before to assemblies the batteries.
Blessing.
cuadra2016@yandex.com
cell+whatsAPP:+50588611441

Precor Exercise... | Answered on Nov 03, 2017


are 2 solution, try to replace the acceleration button, or membrane for to fix it. 2) replace the complete Console.
You can call to the service support and ask for the membrane for to replace, or see if your operator manual for the part number.
Blessing
cuadra2016@yandex.com
whatsApp:+50588611441

Precor 933... | Answered on Nov 03, 2017

Not finding what you are looking for?

Ask a Question

Usually answered in minutes!

Top Precor Experts

Sportsmith LLC
Sportsmith LLC

Level 3 Expert

918 Answers

Ross Metcalfe
Ross Metcalfe

Level 2 Expert

135 Answers

Jose Pino

Level 3 Expert

563 Answers

Are you a Precor Expert? Answer questions, earn points and help others

Answer questions