I have a manual and would be happy to upload a copy to you. I haven't found a Patton website yet. I'm ultimately hoping to find a place where I can buy replacement wheels for my Patton POH2501, but so far, no luck.

Let me know if you're still in need of the manual.

Patton POH2520-U... | Answered on Nov 04, 2015


Most have a one-time thermal fuse wired into the motor. You would have to remove cage and fan blade, unscrew motor mounts, open motor casing, locate fuse by cutting open or sliding off the thermal sleeves, cut fuse out and resolder a new thermal fuse in. Should be able to locate replacement thermal fuse online. Can also just splice ends together but then you lose thermal protection and a fire can result. It is a good temporary fix to diagnose if you have burnt out one of the motor coils.

Patton Dryers | Answered on Oct 19, 2015


The blade may not have been reinstalled correctly and/or the nut may have gotten cross-threaded or stripped in the proces

Patton Dryers | Answered on Oct 06, 2015


You need to include more information: Model number would be helpful. You could also try checking your product manual and seeing if they list a way to unlock the phone.

Patton Heating &... | Answered on Sep 01, 2015


Best place usually is grangers if you just need a motor. Take in motor and they can match up the exactone for you.

Patton Dryers | Answered on Jun 29, 2015


Possibly not the correct pods in the milk house heater .try asking the MFG's tech support

Patton PUH680-U... | Answered on Jun 18, 2015


possible only way is to ix what it sees as the problem

Patton Heating &... | Answered on Mar 13, 2015


most electric fans have steel rotor shafts with bronze bearings.

they "call" them oilite bearings,susposedly because the bronze bushing (it is really a bronze bushing) but called a bearing, is oil impregnanted and susposed to be good for the life of the fan.

that is only true if you expect the life of the fan to be ONLY 18 to 24 months which is the average time that the factory oil lasts.

the oil dries up the longer the fan runs and the shaft makes the bronze bushing begin to heat up due to increased friction and eventually wear the round bronze bushinhg egg shaped.

Try giving your bearings a good healthy squirt of sae 30 wieght oil from a zoom spout-- [pull out straw squeeze bottle refillable oiler.]
I recommend oiling both the front and real fan motor bearings once a month.
This is the most common cause of fan failure.
Because I oil my fans bearings once a month,I still have fans that run from 1940,1950,1960 and 1970. The 1940 GE fan lasted 70 years and is still running strong.

Some newer fans have chinese ball bearings , but the ball bearings also die prematurely from lack of needed oil.
Sometimes, you can pry off the bearing race cover to get oil into the bearing.
a good trick here is to use wd40 if you think you cant get sae 30 into the bearing.
wd40 is a n extreemly light wieght oil that penetrates very well
and gets into places where you think it wont get into .

You can totally wet up a fan motor with either
sae 30 or wd 40 or both without worrying about the electric
motor being harmed by the oil.
the oil,sae 30 or wd 40 wont hurt the motor.

On badly rusted and nearly siezed fan motor bushings , or any electric motor as well, I use first wd40 for penetration and then sae 30 for good long duty lubricatin.

You may have to keep squirting ioil in the motor for 1/2 hour and end up with a puddle of oil under the fan motor, but about 40 % of the time ,you can bring back to life what yo thought was a dead motor. Perserverance is required and faith that you can fix the motor. 40 % of the time you get sucess to one degree or another and 60 % of the time ,its kaput for good.

I got all those fans i mentioned before because other people thought the bearing were seized and shot, and put the fans in the garbage pail where I rescued the fans from.
the bearings were almost siezed but far from shot becaue i got oil in to the shafts and bearings and another 12 to 20 years of life from the fans. However,i do oil them monthly in fan season, which is winter time for me, since I use fans to blow the hot air off my wood stove,

Patton Dryers | Answered on Jan 20, 2015


Typically 'Heat 1' means first stage heat and 'Heat 2' means second stage heat. Essentially a Lo and Hi setting. Just like a hair dryer.

Patton PUH680-U... | Answered on Jan 01, 2015


I would think the contacts are burning out on the line voltage thermostats. The contact areas have been reduced over the years so they last just past the warranty period. If it were mine, I'd locate a line voltage baseboard heater thermostat and adapt the control to operate the heater elements. Much higher amp rating and built more substantially.

Patton PUH682... | Answered on Jan 01, 2015


The thermostat is probably shot. These units are repairable but disposable, meaning the repair will likely cost as much as a new unit. 25330911-xrysbksmd4oe40lchygmaasz-5-0.jpg

Patton Heating &... | Answered on Dec 21, 2014


MILKHOUSE HEATER "CAUTION LIGHT" SOLUTION: Before I explain, let me clear this myth up: this is NOT an issue with the pendulum safety switch (some mistake that for a "mercury" switch). To begin, unplug the heater. Open it up and clean it out. I mean, buy a can of non-chlorinated brake cleaner and squirt all of the contacts good. Below the fan there is a sensor mounted on the heater element box on the bottom. That goes bad and causes it to trip. While you are there, squirt the motor bushings good with the brake cleaner and dab a drop of synthetic motor oil (just a drop) on EACH of the two motor bushings. Personally, I rewired this and bypassed all of the safety features. You can bypass that sensor without soldering or cutting any wires. All you have to do is unscrew the wires from the holder and then unscrew the tiny nuts and tiny bolts. Then bolt the together at one end (note the position) and put it back in the holder and tighten the screw to hold it in. This method fixes the issue completely as it removes the sensor from the equation. In fact, I just did that on my third milkhouse heater and it has been running solid for the last 15 minutes. Use your modified heater with caution! Let the brake cleaner dry before you energize this device!

Patton PUH9000-U... | Answered on Sep 15, 2014

Not finding what you are looking for?

Ask a Question

Usually answered in minutes!

Top Patton Experts

Jay Finke
Jay Finke

Level 3 Expert

1389 Answers

Andrew Taylor
Andrew Taylor

Level 3 Expert

26359 Answers

Tom Chichester

Level 3 Expert

51324 Answers

Are you a Patton Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...