How do I program a norstar t7316e phone to call long distance?
Unless "Set Relocation" is turned on (usually is / should be OFF), plugging a set into a different jack gives it the extension # and programming of that jack. Press Feature * 0 and an Intercom key to find out what the new extension # is, and program that extension to allow long distance. Or change the cross-connect to physically put the old port on the new jack.
How to get incoming calls to two handsets
The system should be configured so that the desired lines, whether CO or extensions, are set to "Appear and Ring" on each set.
Config... Terminals&sets... Show Set... (enter #)... Find...Line Access... Line Assignments... Show Line (enter #)... set to "Appear and Ring" on each set that needs to ring.
You can also have a line "Ring Only" without an appearance (dedicated button), in which case it will show as an intercom call.
How to program feature buttons on meridian 7310?
Go to 7310 set you wish yo program leave handset on hook push feature star 3 then the button you wish to program then feature and
the code you want ex:feature 0 is speed dial that key will now be
programmed for speed dial. You cant program line keys or intercom keys.
How do I fix a no line selected on m7310?
That means you have no lines associated with your set have your administrator do a set copy from a phone that has lines on it. Try intercom 9 for now to see if that works
9/16/2014 10:26:29 PM •
NorStar M7310...
•
Answered
on Sep 16, 2014
•
1,374 views
Dial tone nortel phone
It\'s in system programming: feature CONFIG, Terminals & Sets, enter ext #, Prime Line: set to I/C (for intercom dial tone) or Line xxx. It is probably set to None based on your description.
2 lines dont work
You have to have two lines coming into the phone to have separate lines. Call the phone company.
How to set up caller id
First you have to check your service provider if you have activated this service because here in South Africa it cost a nominal fee for caller ID
Feature codes
Does the two-line display say "Line in use" when you try select the line, or is the indicator next to the line button lit (so to speak), or both? First, try Feature * 0 then press each line key to see if they really are assigned to lines 2 and 3... they could be other functions or multiple appearances of another line.
Password Problem
No trick, does it display "Password:" ?
Nothing displays during password entry, even if you get it wrong. All you can do is press the RETRY softkey and try another. Likely you're using the wrong password.
Change date and time on nortel t7616e
That is a system setting... Depending on what KSU common equipment you have. Feature **TIME might do it, systems with Caller ID Cavan set the clock on an incoming call.
Not finding what you are looking for?