https://search.yahoo.com/yhs/search?hspart=Lkry&hsimp=yhs-newtab&ts=sy&type=YHS_SANM_209692&u_ip=173.89.241.28&obt9bpdyed=0&p=refrigerator+service%252Fusers+manuals¶m1=ij7zzSxCeE_ZFQBIQUqCls6ZzDPk5C0fmXr92VQU50Ci_HUrMceCf_eB8xx8ruvXD7i6jRVjcmbHw6cejr8oAfbkiqpYD6M0dT7Hk9DcpZAswcb_bYMeat-z4JwdnTmAbWoMlPvO-HDEcgVB9zbc_JQzsRk%2c

I’m happy to assist further over the phone at https://www.6ya.com/expert/david_dc2f9e0a44104720

Nor-Lake Norlake... | 178 views | 0 helpful votes


is it plugged in to power ?

Nor-Lake Dual... | 321 views | 0 helpful votes


The pressure control will be fed a live from the thermostat and feed a live to the compressor relay

Nor-Lake Freezer... | 137 views | 0 helpful votes


sounds like a bad defrost terminator or timer wired wrong. won't make temp as the evap is not clear of ice/frost build up. check your wiring diagram for location and operation of terminator.

Nor-Lake... | 88 views | 0 helpful votes


Have it replaced. They are important in the cooling process. Act fast because you could cause further damage. If you can, unplug it until a tech can look at it.

Nor-Lake... | 49 views | 0 helpful votes


Possibly the defrost heater could be faulty or the defrost thermostat or defrost thermistor (sometimes called D-Sensors I believe). If you turn off the fridge and let it defrost itself for 12 hours and then start it again, it may work fine for a week or two (or may even be totally fine in case you left the fridge or freezer door open by accident).

Nor-Lake Norlake... | 127 views | 0 helpful votes


Unfortunately, this model has had quite a few problems, because it is such a complicated refrigerator. Many times a shorted component that is connected to the Iceland main control board will affect completely unrelated items making it easy to chase your tail for hours. I would suspect the freezer thermostor - only because we have had to replace it many times in the past.
Suggest you go to the www.searspartsdirect.com and copy the electrical diagram and then verify electrical reading on the main PCB, to try to isolate the problem.

Nor-Lake... | 251 views | 0 helpful votes


NOTE: This
is a multi-solution answer since I don't have all the tech from your question to pinpoint your problem
But the solution is in here generically, if you read and study the solutions very,very carefully.
First I would check cold control. Thats where you turn it off, if your temp is not warm. it can
be defective and not shutting off. If your temp is warm proceed with the following.
I would check the fan in the freezer. Listen to see if it is running
It moves air to the ref from the freezer
Then check to see if FREEZER CONTROL is turned WARMER WHICH MAKES THE REF COLDER AND VICE-VERSA. SEE?
The ref. temp should be about 33-35
The Freezer temp should be 0 to 10 Any thing below these temps is overkill and a waste of elect
The higher the number you turn it up to is the coldest
But is probably a common defrost problem The ice build up
is not being melted by the defrost system.The fan can't blow through the coils into the fridge.
Take out back panel of freezer to check for ice buildup. The coils should be clean.
There are three components to a defrost system- a heater,heater thermostat, and a timer unless you have a defrost electronic card.
Its best handled by a Technician but you could possibly do it by taking your model number to the nearest appliance parts store and asking for the parts. They are mostly located in freezer ,behind back panel on freezer coils.except the card which is usually located in ref The parts store will have info
Also check fan undernearh Ref in the rear
Clean condenser coils underneath
Make sure back cover is on the fridge. Some take them off and throw them away.
make one out of cardboard if its gone, using the holes of the old one.
.I'm including my article on Refrigerator Repair for your help and convenience.;
Please click or copy and paste into browser for Article

http://www.fixya.com/support/r5816737-fix_refrigerator_psychologically

If you need more help go here:

http://www.applianceaid.com/procedures.html

MORE
TIPS AND TRICKS:
-----------------------------------------------------------------------------------------------------
STOP PAYING FOR EXPENSIVE WATER FILTERS FOR YOUR REF. DO THIS====
http://www.fixya.com/support/r9962087-stop_paying_high_price_refrigerator
-------------------------------------------------------------------------------------------------------
WATER SPLASHING IN FREEZER AT ICEMAKER
THE FILL TUBE IN BACK OF REFRIGERATOR CAN SLIP
AGAINST THE FILL RESERVOIR CAUSING A PARTIAL BLOCKAGE
OR BECOME CLOGGED WITH ICE.
REMOVE THE ICEMAKER AND INSPECT THE FILL TUBE.
RUN WATER IN TUBE TO ELININATE BLOCKAGE AND CHECK
TEMP IN FREEZER. IF TEMP IS BELOW 0 DEGREES, THATS
OVERKILL AND USUALLY A WASTE OF ELECTRICITY TO KEEP IT THAT COLD, NOT TO MENTION THE FILL TUBE FREEZING UP
----------------------------------------------------------------------------------------------------------------------
Thanks for using fixya
Leo Ponder
imufo2
Please VOTE FOR ME AND GIVE ME YOUR TESTIMONIAL IF POSSIBLE, IF THIS WAS HELPFUL
ITWILL BE MUCH APPRECIATED.

Nor-Lake Walk In... | 1,781 views | 0 helpful votes



I would have tried to get you going as fast as possible, but when you have a business things are different. If you have any commercial equipment it is always good to have a source for answers. Model Numbers and Brand Names listed someplace where you know just what you have and know who to call without having to get into an expensive repair trap. I'm not saying that those that came out overcharged you but it does happen a good bit of the time. If I can help feel free to ask here or through my websites, Thanks, John Tripp/AKA Sea Breeze

Nor-Lake Norlake... | 104 views | 0 helpful votes


if the temp is 10f compressor is fine, just need a tune up, call a specialist.

Nor-Lake Freezer... | 133 views | 0 helpful votes


The thermostat sensor is located in the top rear of the interior of the unit, if you locate the dial to change temps on the inside of the unit, the sensor is attached to it, you may have to pull your fridge apart to get to it, but it can be done.

Regards Russ

Nor-Lake Freezer... | 201 views | 0 helpful votes


How about a compressor model number. This will identify the Refrigerant used.

Nor-Lake Norlake... | 356 views | 0 helpful votes


L1 goes to 1-2 on Clock, L2 or Neutral to N on Clock, Defrost heater to 3 on Clock, Defrost Limit/Fan Delay to X on clock

Nor-Lake... | 271 views | 1 helpful votes


Must be kept at 0*F (-18*C) minimum

Nor-Lake Freezer... | 94 views | 0 helpful votes


I have a generic wiring diagram that I use on all my installs that works very well. It is basically the same for most all commercial walk in freezers. Send me a email address and I'll scan and forward what I have.

Nor-Lake... | 391 views | 0 helpful votes


Helloo roger.....Freezers have a thermostat to maintain the proper temperature. These are usually very simple devices. When the freezer reaches the set temperature, the thermostat interrupts the electricity flow to the compressor, which stops cooling. Set your freezer to a colder and colder setting until it doesn't cut out. If you are already at the coldest setting, your only option would be to change the freezer's internal thermostat to one that has a lower cut out capability. Most refrigeration technicians could find the thermostat for you to do this. Joe

Thanks for choosing Fixya!

Nor-Lake Freezer... | 63 views | 0 helpful votes


First thing to do is check for ice build up on the coils and make sure there is air flow in the unit. If there is any ice build up, then try defrosting and cleaning the coils, make sure any dust build up is also cleaned off. If that doesn't help, a new thermostat may be needed. Let me know if you need anything else.

Benjamin

Nor-Lake Norlake... | 39 views | 0 helpful votes


hi go to lower numbers to lower temp jim

Nor-Lake Norlake... | 49 views | 0 helpful votes

Not finding what you are looking for?

Ask a Question

Usually answered in minutes!

Top Nor-Lake Experts

Dennis Boxerman

Level 3 Expert

1280 Answers

Brad Brown

Level 3 Expert

18023 Answers

Steve Allison
Steve Allison

Level 3 Expert

5569 Answers

Are you a Nor-Lake Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...