Hi,
It has lost some freon and is not charged correctly...the unit is pumping down and shutting off on low pressure and then after being off a bit the pressure comes up and it restarts...
Need to check the charge and top it off and you will be good to go..

heatman101

Nor-Lake Norlake... | Answered on Dec 16, 2018


is it plugged in to power ?

Nor-Lake Dual... | Answered on Oct 19, 2018


https://search.yahoo.com/yhs/search?hspart=Lkry&hsimp=yhs-newtab&ts=sy&type=YHS_SANM_209692&u_ip=173.89.241.28&obt9bpdyed=0&p=refrigerator+service%252Fusers+manuals¶m1=ij7zzSxCeE_ZFQBIQUqCls6ZzDPk5C0fmXr92VQU50Ci_HUrMceCf_eB8xx8ruvXD7i6jRVjcmbHw6cejr8oAfbkiqpYD6M0dT7Hk9DcpZAswcb_bYMeat-z4JwdnTmAbWoMlPvO-HDEcgVB9zbc_JQzsRk%2c

I’m happy to assist further over the phone at https://www.6ya.com/expert/david_dc2f9e0a44104720

Nor-Lake Norlake... | Answered on Oct 18, 2017


Yes if the evaporator drain is blocked or not attached correctly it causes the humidity to remain in the refridgerator. Just opening the door will cause the warm are to enter and cause the symtoms of rain if the water is not taken out the drain properly.Hope this helps JT

Nor-Lake Freezer... | Answered on Oct 17, 2017


You should check for air leaks around the door gasket or any other openings in the compartment such as where pipes or wiring is going through the wall. It sounds like a moisture problem from moisture being drawn into the compartment pass door gaskets or access holes.

Nor-Lake Freezer... | Answered on Oct 05, 2017


sounds like a bad defrost terminator or timer wired wrong. won't make temp as the evap is not clear of ice/frost build up. check your wiring diagram for location and operation of terminator.

Nor-Lake... | Answered on Jun 26, 2017


If condenser is clean, and everything seems to be working fine, most likely You will have a leak of freon(very slow usually) and 90% of the chance You will need to get quote to replace evaporator coils. Watch this video, might help to troubleshoot. Hope that helps.

Nor-Lake Norlake... | Answered on Sep 02, 2015


Most likely there is a charge issue. A low charge could create the issues you are having.

Also, a faulty or defrost clock could also create issues if the system is freezing up.

Nor-Lake... | Answered on Feb 10, 2015


The pressure control will be fed a live from the thermostat and feed a live to the compressor relay

Nor-Lake Freezer... | Answered on Apr 27, 2014

Not finding what you are looking for?

Ask a Question

Usually answered in minutes!

Top Nor-Lake Experts

Dennis Boxerman

Level 3 Expert

1280 Answers

Brad Brown

Level 3 Expert

18002 Answers

Steve Allison
Steve Allison

Level 3 Expert

5569 Answers

Are you a Nor-Lake Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...