Lutron Electrical Supplies - Answered Questions & Fixed Issues

0helpful
2answers

Lutron Dimmer - Maestro Desert Stone color is discontinued

You're in a difficult position for which I see few options --- none of them ideal. Short of replacing all your switches and wall plates in a matching color of your choice, a cheaper option might be to find a satin spray paint in or near-enough to your color and gently spraying the new dimmer(s) to match. Alternatively, Eaton makes LED dimmers in "Desert Sand" (but whether their Desert Sand looks anything like Lutron's is beyond me).
5/17/2023 9:34:50 PM • Lutron... • Answered on May 17, 2023 • 71 views
0helpful
2answers

Where can I find a weatherproof dimmer switch for

You need to get the appropriate box and cover. I have never seen a weatherproof dimmer switch. Also normal dimmer switches do not work very well with motors so I am assuming this "dimmer" is for motor use.
10/3/2021 8:22:17 PM • Lutron 1000-Watt... • Answered on Oct 03, 2021 • 76 views
0helpful
1answer

Aquadyne pool controls

Which one? My eyes are poor and I cannot see that far.
10/2/2021 3:21:32 AM • Lutron... • Answered on Oct 02, 2021 • 208 views
0helpful
1answer

Lutron diva dimmer has time delay when turning light on

This is probably normal. If you are using LED bulbs try a different brand. I think you will find the dimmer the setting the longer the delay.
10/2/2021 3:17:49 AM • Lutron ... • Answered on Oct 02, 2021 • 88 views
0helpful
1answer

2 black wires on my light switch

That is normal. I assume the two white wires are connected together in the box.
10/2/2021 3:16:46 AM • Lutron... • Answered on Oct 02, 2021 • 135 views
0helpful
1answer

Two 3 way dimmers controlling one light

This is a no-no unless they are specifically designed to do this.
10/2/2021 3:16:07 AM • Lutron... • Answered on Oct 02, 2021 • 68 views
0helpful
1answer

There is a delay for light to come on when dimmer switch is turned on

That is normal with a lot of dimers. If you have LED lamps try a different brand. If tungsten give the filament time to warm up. I think you will find the dimmer it is set the longer for them to come on.
10/2/2021 3:15:38 AM • Lutron S-600-wh... • Answered on Oct 02, 2021 • 78 views
0helpful
1answer

Yellow jumper wire

The directions tell you where to connect it. My eyes are poor and I cannot see what you have!
10/2/2021 3:13:53 AM • Lutron... • Answered on Oct 02, 2021 • 98 views
0helpful
1answer

Speaker wire

Go to your local big box store, they will gladly sell you one that will solve your problem.
10/2/2021 3:13:10 AM • Lutron Claro... • Answered on Oct 02, 2021 • 58 views
0helpful
1answer

CAN NOT SHUT OFF LUTRON LIGHT. MOTION DETECTOR LUTRON. I CHANGED BULB NOW IT WON'T TURN OFF NO MATTER WHAT I TRIED.

It sounds like you blew the triac (the electronic switch) in the light. You will need to get a replacement module or a new light. Sometimes lightning will cause this. If it was a tungsten lamp they can have a large current surge when it fails.
10/2/2021 2:49:10 AM • Lutron... • Answered on Oct 02, 2021 • 853 views
0helpful
1answer
0helpful
1answer

4 way diagram for lutron Radio RA2 RRD ANF that has 2 other RD RD switches and controling 3 ceiling fans

The only device rated for a motor load is the RRD-8ANS and itequires a neutral connect.

To clarify you have a gang of 3 fans you want to control from more than 2 locations (3 or more existing wall switch boxes)?
1/12/2020 3:08:35 PM • Lutron... • Answered on Jan 12, 2020 • 200 views
0helpful
1answer

12 V halogen track (8 bulbs; replaced withLED); turned on Lutron dv600p dimmer; lights lit & frying sound; then off. all bulbs still good. Differential diagnosis for transformer vs Lutron problem?

Halogen work with AC or DC voltage ... 12 volt LED bulbs are DC. Check that transformer delivers DC, or buy 100 watt IP67 LED driver. Keep in mind the lutron DV-600 is rated for incandescent and halogen loads, and may not function as expected when connected to inductive load like transformer or driver.
10/27/2019 3:25:24 AM • Lutron... • Answered on Oct 27, 2019 • 225 views
0helpful
1answer

I have a 3-way switch in an old house that has three black cloth-covered wires attached. the second switch is up the stairs and I would like to remove completely and cover the hole.

I take it you don't want to just remove the upstairs 3 way switch and wirenut the 3 wires together and put a blank cover plate over the box<?>. Need to know more info. Does the upstairs box have 3 wires only? If no, then likely you will not be able to abandon the upstairs switch box as it will need to remain as an active junction box. If yes, then it becomes a rather lengthy procedure (textual). I'll sketch it out but need an answer the number of wires in upstairs box. Comment below so I may assist further.
4/11/2019 5:00:25 PM • Lutron... • Answered on Apr 11, 2019 • 172 views
0helpful
2answers

Replacing an old lutron skylark dimmer switch with new lutron Diva in a double box with another switch that controls outlet. the breaker keeps tripping when i flip it back on.

There are a lot of DIVA models and you did not post the model number. There are multple configurations and wiring methods.
2/9/2019 6:59:12 PM • Lutron... • Answered on Feb 09, 2019 • 356 views
0helpful
1answer
0helpful
1answer

How do I fix my light switch? I checked my circuit breaker and that's working. I replaced the switch with a new switch and it still doesn't work.

You might look to see if the outlet is GFI protected. It is possible the GFI (Ground Fault Interrupter) tripped and needs to be reset. If so, push the red button (reset button) firmly until it stays down (pushed in). If it does not stay closed, replace it. Also check your light bulb fed by "the switch that does not work", to make sure it did not burn out. Your switch could be good, but the bulb bad. If your light switch is not on a GFI circuit and both Lutron switches are fed by one breaker, get a volt-ohm meter, set it to the volts in a voltage range to read house hold voltage (around 121 volts), and check to see that both switches are receiving 121 volts. Usually you measure with the black probe touching a white (neutral) wire, while the black wire is usually the wire that is in series with the lamp. A black wire may come into the switch and leave as a black wire going to the bulb. If you do not have full voltage reaching your switch, you may have a wiring problem where a wire is no longer making good contact. If you are not sure about how to test with a volt meter, search on your tube for further explanations on how to test to see if a light switch is good.
12/31/2018 6:23:00 AM • Lutron... • Answered on Dec 31, 2018 • 247 views
0helpful
1answer

How can you replace a Lutron Model FD-12 Flourescent dimmer switch with a simple on off switch?

Not sure if you can just splice the extra wires together. The ballast information is what matters converting to just on-off, not the finger switchswitch
12/1/2018 8:50:35 AM • Lutron... • Answered on Dec 01, 2018 • 214 views
0helpful
1answer

Want to dim some puck LED Pots. Do I need a

hi find out the what voltage value of the led ( are they ac. or dc. ) and upon those findings you buy the dimmer switch for dimming
1/2/2018 10:33:48 PM • Lutron GRX-TVI... • Answered on Jan 02, 2018 • 79 views
Not finding what you are looking for?
Lutron Logo

Ask a Question

Usually answered in minutes!

Top Lutron Electrical Supplies Experts