Rain gauge not working
Replace the glass reed switch on the circuit board as it is bad. You must be very careful to orient the replacement switch so that it closes only when the rocker arm is at the vertical position. This will take some work to get right. Use a volt ohm meter and set the Plus lead at the reed switch lead at the top of the board. The meter should show a closed circuit only when the rocker is at the top. Good luck.
1/16/2014 5:17:59 AM •
La Crosse...
•
Answered
on Jan 16, 2014