Kohler generator runs but no water flow. No suction or lost prime

go over board and check that the inlet end for the pump is not blocked with plastic sheeting or debris
4/14/2017 8:18:03 AM • Kohler... • 1,450 views • 0 helpful votes
0helpful
1answer

My 20kW Kohler home generator (nat gas) cranks but won't start. Definitely getting fuel. Everything checked in October with new spark plug. Maybe a setting?

Did you check the oil level? Some generators have a oil sensor that will now allow it to start if the oil level is too low.
3/14/2017 12:38:17 AM • Kohler... • 1,862 views • 0 helpful votes
1helpful
1answer

I have a kohler 4500 watt generator in my 1992 motorhome. starts up and runs fine with the local start switch, but when i use the remote switch, it cranks and doesn't fire.

the remote has separate starting system check the unit it could be the magnetic switch. manual start bypasses this
6/21/2017 7:06:28 PM • Kohler... • 111 views • 1 helpful votes
0helpful
1answer

When flushing, only a small amount of water leaves

replace the flushing controls or install a new cistern
6/21/2017 1:06:03 AM • Kohler Memoirs... • 89 views • 0 helpful votes
0helpful
1answer

Flushing problems

Tank needs more water and the flapper has to stay open longer by adjusting chain so the flapper goes up higher when you flush the unit. Practice and you will get it right.
4/9/2017 1:06:03 AM • Kohler Toilet -... • 427 views • 0 helpful votes
0helpful
1answer

Kohler 3810 toilet wom't flush

Check and see if the handle or the chain inside the tank is broken. If it is, find out the make and model and get replacement. There are many different types of handles out there. Some universal handles won't work, so bring the handle with you when you buy a new one..
3/24/2017 3:40:55 AM • Kohler Plumbing • 460 views • 0 helpful votes
0helpful
1answer

What are the part numbers for Kohler kitchen face K560 for faucet valve set

Hello Rhonda Tweedus, Sorry it took me so long to understand such a clear question... Your style: Bellera (couldn't find an answer either) I looked around for PARTS LISTS... Clever sales tactic ... Perhaps FAUCETSDIRECT.COM might help... (see bottom URL). Their attached has three PDF data sheets... none of which give the DETAIL YOU REQUIRE... I suggest you CALL Kohler direct at 1-800-4KOHLER (1-800-456-4537)... They can IMPROVE if they don't know the have a problem Kohler 560 2BZ Oil Rubbed Bronze 2BZ Bellera Pull Down Kitchen Faucet with... Carnac the Magnificent
4/12/2017 1:17:12 AM • Kohler Plumbing • 249 views • 0 helpful votes
0helpful
1answer

I have a 5000 watt marine generator .Built In the

first I would check is the low oil sensor circuit they can fail or they work best when the oil is low
5/5/2017 4:51:03 AM • Kohler... • 84 views • 0 helpful votes
0helpful
1answer

Not able to remove Kohler Revival K-16102-4A bonnet. That is where it is leaking. I've tried hard to remove it. Ended up damaging the chrome finish still no cigar.

Kohler makes simple things complicated. That being said, put in a Moen.
2/19/2017 12:55:20 PM • Kohler Plumbing • 589 views • 0 helpful votes
0helpful
1answer

How do you find the alternator on a craftman kohler engine

Look in the manual
5/24/2017 1:34:08 PM • Kohler Cameras • 42 views • 0 helpful votes
0helpful
1answer

K-4763 Zofa soft close toilet seat

CLR .works well
4/24/2017 8:42:03 PM • Kohler Home • 82 views • 0 helpful votes
0helpful
1answer

Lincoln ranger 8 and kohler engine command 20. engine does not pull gas to carburetor. Putting little gas directly in carburetor; machine runs until finish gasoline inside carburator.

engines don't "pull" fuel to carb , it either gravity flows (tank over top carb) there or its pumped there , I do believe the kohler engines from 8 hp thru 25 hp use a vacuum activated fuel pump (three hoses on it) these do go bad over time and need replaced , also there are fuel filters on all these engines that need to be replaced seasonally they are not cleanable there disposable
12/15/2016 9:22:20 PM • Kohler... • 1,906 views • 0 helpful votes
0helpful
1answer

2oo2 kohler is not getting gas

Does this machine have a fuel filter if so make sure it's clean. Does it have a fuel bowl? Take it off and clean it out real good . also clean the fuel jet. These are why the engines do not start or run properly if one of these are dirty. Dirt keeps the fuel out of the carb.
4/16/2017 5:10:41 PM • Kohler... • 49 views • 0 helpful votes
1helpful
1answer

Any ideas to loosen up a cartridge in a shower faucet. The make is kohler

Acetic acid, also known as vinegar.
2/16/2017 7:29:50 PM • Kohler Plumbing • 181 views • 1 helpful votes
0helpful
1answer

Hi there, Can I replace the cartridge of Kohler K-597-VS Simplice kitchen faucet with a cartridge from Grohe Parkfield 30215000 ?

best talk with a plumbers supply retailer as they will know if it interchanges
11/11/2016 7:40:20 AM • Kohler Plumbing • 250 views • 0 helpful votes
1helpful
1answer
2helpful
2answers

I have a 7kw Kohler marine generator that shuts of when boat gets up on plane New impeller New fuel filter I started it runs for a while then shuts off It takes a bit to start but runs for 20 plus hrs

I take it that this unit runs the power on board and is permanently fixed in the boat you mention new impeller so logically that means that it is water cooled drawing the cooling water from outside (underneath the boat) pursuing logic further if that is the case then there is a shut down circuit for the water flow to prevent overheating should the water inlet become blocked ( weeds, plastic cloth etc) from your question and statement I would be looking in that area to make sure water flow is not restricted or the protection circuit is operational ( no corrosion in terminals and wires )
10/1/2016 12:59:09 AM • Kohler... • 489 views • 2 helpful votes
0helpful
1answer

I have a Kohler 7.3 ECD generator with error code UVunder frequency. Restarted gen and it ran for one hour so I shut it off. What's the problem?

check the operating rpms the rpms determine the voltage and frequency and can be adjusted at the governor spring setting adjust it until the voltmeter reads the required voltage set slightly above to allow for rpms drop under load for example if 240 volts set around 250 volts and that will drop back to 240 volts under load if 110 set around 115 and that will drop back under full load both frequency and volts are dependant on rpms
9/20/2016 10:23:20 PM • Kohler... • 610 views • 0 helpful votes
0helpful
2answers

How can I reset the "programmed exercise mode" on my Kohler 12 RES generator

You will likely need to reference your instruction manual for that specific control panel.
8/7/2016 2:06:35 PM • Kohler 12 kW... • 2,065 views • 0 helpful votes
Not finding what you are looking for?

Ask a Question

Usually answered in minutes!

Top Kohler Experts

john h

Level 3 Expert

29494 Answers

Brad Brown

Level 3 Expert

19187 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66931 Answers

Are you a Kohler Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...